Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Biosci. j. (Online) ; 31(4): 1030-1036, july/aug. 2015.
Article in English | LILACS | ID: biblio-964555

ABSTRACT

Due to its rapid growth, drought tolerance and short cycle, the proso millet crop has attracted the attention of producers and technicians as an alternative to crop rotation and formation of straw for subsequent planting of soybean in no-tillage system in some regions of the state of Rio Grande do Sul (RS), Brazil. However, there is limited information on application times and rates of nitrogen (N). Therefore, the objective of this study was to evaluate application times and rates of N in proso millet crop, under some plant parameters and in the final grain yield. The experiment was conducted in the Federal University of Santa Maria, campus of Frederico Westphalen, in the period of September to November2012. The experiment design was that of randomized blocks, in a4 x 4factorial design, with four replications. The treatments consisted of the combination of four rates of N (zero, 30, 60 and 90 kg ha-1) and four different application times of N: all at sowing, 30 % at sowing and the remaining15 days after emergence (DAE), 30 % at sowing and the remaining 30 days DAE, 30 % at sowing and the remaining45 days DAE. There was no significant response as regards the application times of Nin the proso millet crop. On the other hand, there was a significant and linear response in plant height, dry matter production, stem diameter, panicle length and in the final grain yield within crease in rates of N.


A cultura do painço pelo seu rápido crescimento, tolerância a seca e ciclo curto, tem despertado atenção de produtores e técnicos como alternativa de rotação de cultura e formação de palhada para posterior semeadura da soja no sistema plantio direta em algumas regiões do Rio Grande do Sul. No entanto, são escassas as informações sobre a época de aplicação e doses de nitrogênio (N). Por isso, o objetivo desse trabalho, foi avaliar épocas de aplicação e doses de N na cultura do painço, sobre alguns parâmetros de planta e na produtividade final de grãos. O experimento foi desenvolvido na Universidade Federal de Santa Maria, Campus de Frederico Westphalen, no período de setembro a novembro de 2012. O delineamento experimental foi de blocos ao acaso, num esquema fatorial 4 x 4, com quatro repetições, sendo os tratamentos constituídos da combinação de quatro doses de N (zero, 30, 60 e 90 kg ha-1) e quatro diferentes épocas de aplicação do N: todo na semeadura, 30% na semeadura e o restante 15 dias após a emergência (DAE), 30 % na semeadura e o restante 30 dias DAE, 30 % na semeadura e o restante 45 dias DAE. Não houve resposta significativa quanto à época de aplicação de N na cultura do painço. Houve uma resposta significativa e linear na altura de planta, produção de matéria seca, diâmetro do colmo, comprimento da panícula e no rendimento final de grãos com o aumento nas doses de N.


Subject(s)
Plants , Glycine max , Edible Grain , Efficiency , Millets , Nitrogen
2.
Ciênc. rural ; 44(3): 418-424, mar. 2014. ilus, tab
Article in Portuguese | LILACS | ID: lil-704129

ABSTRACT

A elevada produção de dejeto líquido de suínos faz do solo a principal alternativa para a sua utilização na forma de fertilizante orgânico. Contudo, a adição de resíduos orgânicos nos sistemas de manejo do solo é um fator que pode influenciar a biota do solo. O objetivo deste trabalho foi avaliar a influencia da aplicação de doses de dejeto líquido de suíno na fauna do solo em diferentes sistemas de cultivos. O trabalho foi desenvolvido em área experimental no município de Taquaruçu do Sul, RS. O delineamento foi em blocos casualisados em arranjo fatorial (2x5), sendo dois sistemas de manejo do solo (mínimo e plantio direto) e cinco doses (0, 20, 40, 80m³ ha-1 de dejeto líquido de suíno e adubação química) com quatro repetições. As coletas da fauna edáfica foram realizadas com armadilhas tipo PROVID, em parcelas de 22,5m². Avaliou-se o total de grupos, colêmbolos, ácaros, abundância, riqueza, índice dominância de Simpson, diversidade de Shannon e o índice de Pielou. Os resultados indicam que o sistema plantio direto associado a 40 e 80m³ ha-1 resultam em maior abundância de organismos, ocasionada pelo maior número de colêmbolos. A população de ácaros é maior no cultivo mínimo, em comparação ao sistema plantio direto na dose de 80m³ ha-1. No sistema plantio direto, a dominância de Simpson aumenta e a diversidade de Shannon diminui com a elevação das doses de dejeto líquido de suíno.


The high production of liquid pig slurry makes the soil, the main alternative to its use as an organic fertilizer. However, the addition of organic residues in soil management systems is a factor that may influence the soil biota. The aim of this study was to evaluate the influence of dose application of liquid swine manure on soil biota in different cropping systems. The study was conducted in the experimental area located in the Taquaruçu do Sul. The design was a randomized block factorial arrangement (2x5), two soil management (minimum and no tillage) and five doses (0, 20, 40, 80m³ ha-1 of liquid swine slurry and chemical fertilizer - ROLAS) with four replications. Sampling of soil biota was carried out with PROVID traps in plots of 22.5m². It was evaluated the total group, springtails, mites, abundance, richness, Simpson’s index, Shannon’s diversity and Pielou’s index. The results indicate that no tillage system associated with 40 and 80m³ ha-1 resulted in a greater abundance of organisms, caused by the greater number of springtails. The mite population is larger in minimum tillage compared to no tillage at a rate of 80m³ ha-1. In no-tillage increases the dominance of Simpson and Shannon diversity decreases with increasing levels of liquid swine manure.

3.
Braz. dent. j ; 22(5): 392-397, 2011. ilus, tab
Article in English | LILACS | ID: lil-601840

ABSTRACT

Removable partial dentures (RPD) demand specific hygienic cleaning and the combination of brushing with immersion in chemical solutions has been the most recommended method for control of biofilm. However, the effect of the cleansers on metallic components has not been widely investigated. This study evaluated the effect of different cleansers on the surface of RPD. Five disc specimens (12 mm x 3 mm metallic disc centered in a 38 x 18 x 4 mm mould filled with resin) were obtained for each experimental situation: 6 solutions [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05 percent sodium hypochlorite (NaOCl), and distilled water (DW) control] and 2 Co-Cr alloys [DeguDent (DD) and VeraPDI (VPDI)] were used for each experimental situation. A 180-day immersion was simulated and the measurements of roughness (Ra, µm) of metal and resin were analyzed using 2-way ANOVA and Tukey’s test. The surface changes and tarnishes were examined with a scanning electronic microscopy (SEM). In addition, energy dispersive x-ray spectrometry (EDS) analysis was carried out at representative areas. Visually, NaOCl and MI specimens presented surface tarnishes. The roughness of materials was not affected by the solutions (p>0.05). SEM images showed that NaOCl and MI provided surface changes. EDS analysis revealed the presence of oxygen for specimens in contact with both MI and NaOCl solutions, which might suggest that the two solutions promoted the oxidation of the surfaces, thus leading to spot corrosion. Within the limitations of this study, it may be concluded that the NaOCl and MI may not be suitable for cleaning of RPD.


As próteses parciais removíveis (PPR) exigem higienização específica e a associação da escovação com imersão em soluções químicas tem sido o método mais recomendado para controle do biofilme. Entretanto, os efeitos destas soluções não são amplamente reportados em componentes metálicos. Este estudo avaliou o efeito de diferentes agentes de higienização na superfície dos componentes de uma PPR. Foram confeccionados 5 espécimes (disco metálico de 12 x 3 mm centralizado em uma tira de resina com 38 x 18 x 4 mm) para cada situação experimental: 6 soluções [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), hipoclorito de sódio 0,05 por cento (HS) e água destilada (AD) como controle)] e 2 ligas de cobalto-cromo [DeguDent (DD) e Vera PDI (VPDI)] foram utilizadas para cada situação experimental. Foram simuladas imersões de 180 dias. As aferições de rugosidade (Ra, μm) tanto em porção metálica quanto em resina acrílica termopolimerizável foram submetidos ao ANOVA e ao teste de Tukey. As alterações superficiais e manchas foram examinadas por meio de microscopia eletrônica de varredura (MEV). Áreas de interesse foram submetidas à espectrometria por energia dispersiva por raios X (EDS). Visualmente, puderam ser verificadas manchas nas superfícies metálicas quando utilizados HS e MI. A rugosidade dos materiais não foi afetada pelas soluções (p>0,05). As fotomicrografias evidenciaram que HS e MI ocasionaram alterações superficiais. As análises de EDS revelaram a presença de oxigênio nos grupos HS e MI, o que pode sugerir que estas duas soluções causaram oxidação das superfícies, provocando pontos de corrosão. Dentre as limitações do presente estudo, pode-se concluir que estas soluções não são apropriadas para a higienização das PPR.


Subject(s)
Humans , Acrylic Resins/chemistry , Chromium Alloys/chemistry , Denture, Partial, Removable , Dental Materials/chemistry , Denture Cleansers/chemistry , Borates/chemistry , Corrosion , Cetylpyridinium/chemistry , Chlorhexidine/analogs & derivatives , Chlorhexidine/chemistry , Citric Acid/chemistry , Immersion , Materials Testing , Microscopy, Electron, Scanning , Oxidation-Reduction , Oxygen/analysis , Spectrometry, X-Ray Emission , Surface Properties , Sodium Hypochlorite/chemistry , Sulfates/chemistry , Time Factors
4.
Article in Portuguese | LILACS, BBO | ID: lil-663263

ABSTRACT

Objetivo: analisar a quantidade de energia luminosa que chega ao material cimentante durante a polimerização de uma peça protética. Metodologia: Foram confeccionados corpos de prova padronizados de cerômero e de porcelana, que mediam 1,4 cm de diâmetro cada. Os corpos de prova foram divididos em grupos conforme a sua espessura (1mm ou 1,5mm) e o tipo de material. Foi utilizado um radiômetro para analisar a intensidade luminosa que atravessou a peça e os resultados obtidos foram expressos em mw/cm². Para todos os grupos, foi utilizada a distância de 3mm entre o aparelho fotopolimerizador e os corpos de prova. A padronização desta distância foi baseada nos resultados obtidos quando o aparelho fotopolimerizador foi apoiado diretamente sobre a célula fotossensível do radiômetro (distância 0mm) e obteve-se um resultado médio de 852,13 ± 18,022mw/cm² e quando o aparelho fotopolimerizador foi afastado a uma distância de 3mm e a média obtida foi de 671,37±37,869 mw/cm². Resultados: Os resultados mostraram que a média do grupo de porcelana, com 1mm de espessura, foi de 222,20 ± 22,048 mw/cm². O grupo do cerômero com 1mm de espessura apresentou uma média de 156,70 ± 12,009 mw/cm², a porcelana com 1,5mm de espessura, apresentou uma média de 139,03 ± 8,385 mw/cm². Já, o grupo cerômero com 1,5mm, absorveu completamente a luz. Conclusão: o grupo da porcelana, com 1 mm de espessura, permitiu que parte da energia luminosa chegasse ao material cimentante durante a polimerização e que a intensidade do aparelho fotopolimerizador e o tempo de exposição durante a cimentação protética devem ser ajustados conforme o tipo e a espessura do material utilizado.


Objective: this study to analyze the amount of luminous energy that arrived at the cimentante material during the polymerization of a prosthetic part. Methods: Standardized bodies of test of resin composites and porcelain had been confectioned and measured 1,4 cm of diameter each. The test bodies had been divided in groups in agreement its thickness (1mm and 1,5mm) and the type of material. A radiometer was used to analyze the luminous intensity that crossed the part and the gotten results had been express in mw/cm². Were used in the distance of 3mm between the photopolimerizer device and the bodies of test. The standardization of this distance was based on the gotten results when the photopolimerizer device was supported directly on the photosensitive cell of the radiometer (distance 0mm) and got 852.13 ± 18.022 mw/cm² an average result of and when the photopolimerizer device was moved away to a distance from 3mm, the average lowered for 671,37 ± 37,869 mw/cm². Results: The results had shown that the average of the group of porcelain, with 1mm of thickness, was of 222,20 ± 22,048 mw/cm². The group of resin composite of 1mm of thickness presented a average of 156,70 ± 12,009 mw/cm², the porcelain with 1,5mm presented a average of 139,03 ± 8,385 mw/cm². Already, the resin composite group of 1,5mm, absorbed the light completely. Conclusion: the group of the porcelain, with 1 mm of thickness, allowed that it has left of the luminous energy arrived at the cimentated material during the polymerization and that the intensity of the photopolimerizer device and the time of exposition during the prosthetic face-hardenings must be adjusted in agreement to the type and the thickness of the used material.


Subject(s)
Dental Materials/chemistry , Dental Porcelain , Light-Curing of Dental Adhesives , Polymerization , Brazil , Analysis of Variance , Cementation
SELECTION OF CITATIONS
SEARCH DETAIL