Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Article | IMSEAR | ID: sea-220219

ABSTRACT

Background: Managing a brain tumor during pregnancy is a highly confusing and challenging situation, complicated by several technical, medical, ethical, and sociocultural concerns. The interests of the mother and child are often pitted against each other, for which legal opinion may occasionally be needed. Case Report?We present the report of a young lady with intracranial well-differentiated chondrosarcoma who was determined to be pregnant in the immediate postoperative period. We discuss the management of challenges and dilemmas in devising optimum therapy, and the modifications and care required at each step to help safeguard maternal and fetal health. Risks with therapeutic radiation and measures to assess and pre-empt fetal doses that may assist decision-making are also discussed. Conclusion?Radiation therapy during pregnancy is challenging and requires multidisciplinary involvement and psychosocial support for the patient and family.

2.
Article | IMSEAR | ID: sea-207316

ABSTRACT

Background: Pregnancy Related Acute Kidney Injury (PRAKI) is a major cause of maternal and foetal morbidity and mortality in developing countries. The incidence has declined due to improvements in reproductive health but it is still associated with significant perinatal mortality and maternal morbidity. It may be due to decrease in renal perfusion or ischemic tubular necrosis from a variety of conditions encountered during pregnancy. Our study aims at determining the predisposing factors and causes of AKI during pregnancy and its impact on maternal and foetal outcome.Methods: A retrospective cohort study over a period of 5 years was conducted on pregnant women with AKI as per inclusion and exclusion criteria. The detailed history, events, mode of delivery, cause leading to AKI, management, hospital stay, maternal and foetal outcome were studied in detail and evaluated. These patients were classified according to RIFLE criteria and were followed up for hospital stay and residual morbidities.Results: The incidence of PRAKI in the study was 0.07% (36 out of 50,735 deliveries) and among obstetric ICU patients, it was 6.8%. Most of the majority of the cases were unbooked (66.7%) and multipara (61.1%). Maternal morbidity was seen in 66.7% and mortality was 27.8%. Poor foetal outcome was seen in 44.4%.Conclusions: Haemorrhage is the most common cause of PRAKI, followed by toxaemia of pregnancy and sepsis. Early detection and meticulous management of haemorrhage, hypertension and sepsis reduce the incidence of PRAKI and associated maternal mortality.

3.
J Cancer Res Ther ; 2019 Oct; 15(5): 1035-1041
Article | IMSEAR | ID: sea-213474

ABSTRACT

Aim: In the present study, surface doses within the target area and contralateral breast (CLB) received during conventional treatment of carcinoma breast are evaluate and compared for treatment on two different beam energies, i.e., Co-60 γ-ray and 6 MV X-ray beams with thermoluminescent dosimeter, LiF:Mg, Ti (TLD-100). Materials and Methods: The study includes a group of 23 patients comprising 11 patients treated with Co-60 γ-ray beam and 12 patients by 6 MV X-ray beam. Results and Discussion: The treatment using Co-60 γ-ray and 6 MV X-ray beams contributes an average percentage dose of 8.15% ± 0.56% and 4.73% ± 0.94%, respectively, to CLB in mastectomy patients. The contribution of tangential fields (mastectomy) to the CLB doses ranges between 12.71 and 16.40 cGy (5.45%–7.03%) for treatment with Co-60 γ-ray beam and 6.33–10.95 cGy (1.86–4.69%) for treatment with 6 MV X-ray beam. The supraclavicular field (SCF) contributes 1.45%–1.93% and 1.02%–1.43% for treatment with Co-60 γ-ray and 6 MV X-ray beams, respectively. The average surface dose (normalized with breast dose) 89.1% ± 8.5% for Co-60 beam in the SCF region differs significantly from the 60.2% ± 13.0% value for 6 MV X-ray beam. Conclusion: The CLB doses for mastectomy patients are higher for Co-60 beam as compared to 6 MV X-ray beam, and better dose homogeneity is achieved within the irradiated breast from 6 MV X-ray beam. The CLB doses are slightly higher for patients treated with breast conservative radiotherapy or lumpectomy. The average surface dose to SCF decreases by ~30% of treated breast dose for treatment with 6 MV X-ray beam

4.
J Cancer Res Ther ; 2019 Jan; 15(1): 204-210
Article | IMSEAR | ID: sea-213592

ABSTRACT

Purpose: The aim of the present study was to compare the positional accuracy of varian's exact-arm (E-arm) and retractable-arm (R-arm) supporting electronic portal imaging device (EPID) systems (amorphous silicon flat-panel detector) using the intensity-modulated radiotherapy (IMRT) graticule phantom. Materials and Methods: The known shifts of 0.5, 1.0, and 1.5 cm were introduced to the given phantom in longitudinal, lateral, and vertical directions, respectively, with respect to treatment couch of medical linear accelerator. The experiment was repeated for different gantry angle and varying source to imager distances (SIDs). The images were acquired for each shift at varying SIDs and beam orientations for both EPID supporting systems. The corresponding shifts obtained from treatment planning system (TPS) were recorded and compared. Results: The known (expected) and observed (recorded from TPS) shifts obtained for different beam angles (namely, 0°, 90°, 180°, and 270° for anterior, left lateral, posterior, and right-lateral portal images, respectively) in the longitudinal, lateral, and vertical direction at varying SID were compared. The maximum shift in the observed value from the expected one was 3 and 2 mm, respectively, out of the all beam configuration for R-arm and E-arm. These shifts were randomly observed for all imager position and beam orientation. Conclusion: The IMRT graticule phantom is an effective tool to check the mechanical characteristic and consistency of different EPID supporting arms. The effect of EPID sag due to gravity (gantry and treatment couch) was not significant for detection of shift in patient's position. The E-arm support EPID has better mechanical stability and accuracy in detection of patient's position than that of R-arm

SELECTION OF CITATIONS
SEARCH DETAIL