Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Rev. bras. ortop ; 57(1): 120-127, Jan.-Feb. 2022. tab, graf
Article in English | LILACS | ID: biblio-1365755

ABSTRACT

Abstract Objectives Glenoid component failure is the main cause of total shoulder arthroplasty (TSA) revision, and component design seems to influence the failure rate. The aim of the present study was to clinically and radiographically (through X-rays and computed tomography scan) evaluate the results of TSA using a minimally cemented glenoid component. Methods Total should arthroplasties performed using the minimally cemented Anchor Peg (DuPuy Synthes, Warsaw, IN, USA) glenoid component between 2008 and 2013 were evaluated. University of California at Los Angeles (UCLA) scores were calculated, and standardized plain film and computed tomography images were obtained, at a minimum follow-up of 24 months. The presence of bone between the fins of the central component peg, which indicates its integration, was assessed on the images, as well the presence of radiolucent lines around the glenoid component. Results Nineteen shoulders in 17 patients were available for evaluation. According to the UCLA score, clinical results were satisfactory in 74% of cases and fair in 21% of cases. One patient had a poor result. Component integration was found in 58% of patients (total in 42% and partial in 16%). Radiolucent lines were observed in 52% of cases. No relationship was detected between component integration and clinical results. Conclusion Satisfactory clinical results were achieved in most patients undergoing TSA using a minimally cemented glenoid component. Radiolucent lines around the glenoid component are common, but do not interfere with the clinical results. Level of evidence IV; Case series; Treatment study.


Resumo Objetivos A falha do componente glenoidal é a principal causa de revisão da artroplastia total do ombro (ATO) e sua frequência parece ser influenciada pelo design do componente. O objetivo deste estudo foi a avaliação clínica e radiográfica (através de raios X e tomografia computadorizada) dos resultados da ATO com componente glenoidal minimamente cimentado. Métodos O presente trabalho analisou ATOs realizadas com componente glenoidal Anchor Peg (DuPuy Synthes, Warsaw, IN, EUA) minimamente cimentado entre 2008 e 2013. Por um período mínimo de acompanhamento de 24 meses, escores segundo critérios da University of California at Los Angeles (UCLA) e imagens padronizadas de radiografia simples e tomografia computadorizada foram analisadas. A presença de osso entre as aletas do pino do componente central, que é um indicador de sua integração, foi avaliada nas imagens, bem como a presença de linhas radiotransparentes ao redor do componente glenoidal. Resultados Dezenove ombros de 17 pacientes foram avaliados. De acordo com o escore da UCLA, os resultados clínicos foram satisfatórios em 74% dos casos e moderados em 21% dos casos. O resultado foi ruim em um paciente. A integração de componentes foi observada em 58% dos pacientes, sendo total em 42% e parcial em 16% dos casos. Linhas radiotransparentes foram observadas em 52% dos pacientes. Nenhuma relação entre a integração de componentes e os resultados clínicos foi detectada. Conclusão A maioria dos pacientes submetidos à ATO com componente glenoidal minimamente cimentado apresentou resultados clínicos satisfatórios. Linhas radiotransparentes ao redor do componente glenoidal são comuns, mas não interferem nos resultados clínicos Nível de evidência IV; Série de caso; Estudo terapêutico.


Subject(s)
Humans , Male , Female , Middle Aged , Shoulder , Prosthesis Failure , Tomography , Radiographic Image Enhancement , Arthroplasty, Replacement
2.
Rev. bras. ortop ; 55(5): 585-590, Sept.-Oct. 2020. tab, graf
Article in English | LILACS | ID: biblio-1144216

ABSTRACT

Abstract Objective Coracoid osteolysis has been described as a possible complication after the Latarjet procedure. The aim of the present study was to investigate the incidence and risk factors associated to coracoid graft osteolysis and to correlate them with clinical results. Methods A retrospective review of 38 Latarjet procedures was conducted. Computed tomography (CT) scans were obtained from all of the patients before and at least 1 year after the surgery. Coracoid osteolysis was evaluated and correlated to preoperative factors, namely: age, smoking status, and preoperative glenoid bone loss. The patients were divided into 2 groups: A (no or minor bone resorption) and B (major or total bone resorption). The functional outcome was determined by the Rowe score. Results Coracoid graft osteolysis occurred in 22 cases (57.8%). The mean preoperative glenoid defect was 22.8% in group A, and 13.4% in group B (p= 0.0075). The mean ages of the subjects in both groups were not significantly different. Smoking did not seem to affect the main outcome either, and no correlation was found between graft osteolysis and postoperative range of motion, pain, or Rowe score. There were no cases of recurrent dislocations in our sample, although four patients presented with a positive anterior apprehension sign. Conclusion Bone resorption of the coracoid graft is present in at least 50% of the patients submitted to the Latarjet procedure, and the absence of significant preoperative glenoid bone loss showed to be the only risk factor associated with severe graft osteolysis, even though this did not influence significantly the clinical outcome.


Resumo Objetivo Osteólise do processo coracoide é descrita como uma possível complicação da cirurgia de Latarjet. O objetivo do presente estudo foi avaliar a incidência e fatores de risco associados à osteólise do enxerto do coracoide e correlacioná-los com resultados clínicos. Métodos Foi realizada uma revisão retrospectiva incluindo 38 casos submetidos ao procedimento de Latarjet. Em todos os casos, foi realizada uma tomografia computadorizada antes e pelo menos 1 ano após a cirurgia. A presença de osteólise do coracoide foi avaliada e correlacionada com os seguintes fatores de risco: idade, tabagismo, e perda óssea pré-operatória da glenóide. Os pacientes foram divididos em dois grupos: A (ausência ou menor reabsorção óssea) e B (maior reabsorção óssea ou total). A avaliação funcional foi determinada através do escore de Rowe. Resultado Osteólise do processo coracoide ocorreu em 22 casos (57,8%). O defeito ósseo médio pré-operatório da glenóide foi de 22,8% no grupo A e de 13,4% no grupo B (p= 0.0075). A média de idade dos casos em ambos os grupos não apresentou diferença estatística. Tabagismo também não esteve relacionado com diferenças no resultado. Não houve correlação entre a presença de osteólise e o arco de movimento, dor ou ao escore de Rowe. Não houve casos de reluxação; entretanto, quatro pacientes apresentaram apreensão anterior no exame físico. Conclusão A reabsorção do processo coracoide ocorreu em pelo menos 50% dos pacientes submetidos à cirurgia de Latarjet, e a ausência pré-operatória de perda óssea significativa da glenóide foi o único fator de risco associado a osteólise mais severa do enxerto, porém sem influência no resultado clínico.


Subject(s)
Humans , Male , Adult , Osteolysis , Pain , Shoulder Dislocation , Shoulder Joint , Tobacco Use Disorder , Bone and Bones , Bone Resorption , Smoking , Tomography, X-Ray Computed , Range of Motion, Articular , Coracoid Process , Joint Instability
4.
Rio de Janeiro; s.n; 2017. 77 p.
Thesis in Portuguese | LILACS, ColecionaSUS | ID: biblio-1179684

ABSTRACT

A artroplastia total é necessária no tratamento de casos graves de fraturas, artrite reumatoide e osteoartrose do cotovelo. Durante o procedimento, a cápsula articular é parcialmente ressecada, levando à perda de mecanorreceptores que seriam importantes para a percepção do movimento passivo em condições normais. Acreditamos que o desenvolvimento de um equipamento capaz de realizar a medição da cinestesia, através do limiar de percepção do movimento passivo (LPMP), ajudará a esclarecer o quanto este procedimento impacta negativamente a propriocepção, e se esse efeito repercute na esfera clínica. O Propriomaq II foi criado nesse contexto, permitindo a mobilização passiva da articulação e o acionamento de um botão pelos sujeitos examinados ao perceberem o movimento, viabilizando o cálculo do seu limiar de percepção. Vinte e um pacientes hígidos foram submetidos ao teste, repetindo as medidas após ao menos um dia, visando validar o método. Com o objetivo de esclarecer o efeito da artroplastia total sobre o LPMP do cotovelo, oito pacientes portadores de prótese total foram submetidos ao exame, comparando o lado operado ao contralateral. Os resultados demonstraram latência significativamente maior para a percepção do movimento passivo nos cotovelos operados, ou seja, pior propriocepção quando comparados ao lado contralateral. Não foi encontrado, entretanto, correlação significativa entre o LPMP e os resultados funcionais no lado artroplastia. O Propriomaq II apresentou boa reprodutibilidade (R2=0,94) na medição do LPMP do cotovelo, e evidenciou conclusivamente o prejuízo proprioceptivo presente em cotovelos submetidos a artroplastia total. Esses resultados demonstram a necessidade de maior preservação das partes moles periarticulares durante a artroplastia total do cotovelo, e uma ênfase da reabilitação fisioterapêutica visando recuperação da propriocepção


Total elbow arthroplasty is necessary in the treatment of severe fractures, rheumatoid arthritis and degenerative elbow arthritis. During the procedure, the articular capsule is partially resected, leading to loss of mechanoreceptors that would be important for the perception of articular motion in normal conditions. We believe that the creation of an equipment capable of assessing kinesthesia through the measurement of threshold to detection of passive motion (TDPM) will help quantify the negative effects this procedure has on elbow proprioception, and understand if this has any relevant impact in the clinical sphere. The Propriomaq II was created in this context, allowing passive mobilization of the elbow joint and the activation of a button by the examined subjects when motion is perceived, thus providing a means of calculating it's detection threshold. Twenty-one healthy patients were subjected to the test, repeating the measurements after at least one day, so the method could be validated. In order to clarify the effects of total arthroplasty on elbow TDPM, eight patients were subjected to the test, comparing the total elbow side to the contralateral side. The results revealed significantly higher thresholds to detection of motion, or worse proprioception, on the prosthesis side in comparison to the contralateral side. These results held no correlation, however, to the clinical outcome of the elbow replacement. The Propriomaq II proved reproducible (R2=0,94) in the measurement of elbow TDPM and has conclusively exposed the proprioceptive deficits present in total arthroplasty elbows. These results demonstrate the need for greater preservation of peri-articular soft tissues during total elbow arthroplasty, and an emphasis of rehabilitation on the recovery of proprioception


Subject(s)
Arthroplasty, Replacement, Elbow/adverse effects , Sensory Thresholds
5.
Rev. bras. ortop ; 49(3): 279-285, May-June/2014. graf
Article in English | LILACS | ID: lil-712787

ABSTRACT

OBJECTIVE: to present a retrospective analysis on the clinical-functional results and complications among patients with rotator cuff arthropathy (RCA) who underwent reverse arthroplasty of the shoulder. METHODS: patients with a diagnosis of RCA associated with pseudoparalysis of anterior elevation who underwent reverse arthroplasty of the shoulder with a minimum follow-up of one year were selected. RESULTS: preoperative information was gathered from our shoulder and elbow arthroplasty register, comprising age, sex, laterality, history of previous procedures, Constant's functional scores and the preoperative range of motion as described in the protocol of the American Academy of Shoulder and Elbow Surgery (ASES). After a mean follow-up of 44 months, 17 patients (94%) were satisfied with the result from the procedure. CONCLUSION: reverse arthroplasty for treating RCA in patients with pseudoparalysis of the shoulder was shown to be effective in achieving a statistically significant improvement in range of motion regarding anterior flexion and abduction. However, in this series, there was no improvement in range of motion regarding external and internal rotation. Reverse arthroplasty is a procedure that reestablishes shoulder joint function in patients who previously did not present any therapeutic possibilities...


OBJETIVO: apresentar uma análise retrospectiva dos resultados clínico-funcionais e das complicações dos pacientes com artropatia do manguito rotador (AMR) submetidos à artroplastia reversa do ombro. MÉTODOS: foram selecionados pacientes com diagnóstico de AMR associada à pseudoparalisia da elevação anterior submetidos à artroplastia reversa do ombro com seguimento mínimo de um ano. RESULTADOS: foram coletadas informações pré-operatórias, por meio do nosso Registro de Artroplastias do Ombro e Cotovelo, que consistiam em idade, sexo, lateralidade, história de procedimentos prévios, escores funcionais de Constant, além da amplitude de movimentos pré-operatórios, conforme protocolo da American Academy of Shoulder and Elbow Surgery (Ases). Com seguimento médio de 44 meses, 17 pacientes (94%) estavam satisfeitos com o resultado do procedimento. CONCLUSÃO: a artroplastia reversa no tratamento da AMR em pacientes com pseudoparalisia do ombro demonstrou-se efetiva na melhoria, com significância estatística, da amplitude de movimentos de flexão anterior e abdução. Porém, nesta série não houve melhoria da amplitude dos movimentos de rotação externa e interna. A artroplastia reversa é um procedimento que restabelece a função da articulação do ombro em pacientes que previamente não apresentavam possibilidades terapêuticas...


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Arthroplasty , Shoulder/surgery , Prostheses and Implants , Rotator Cuff
SELECTION OF CITATIONS
SEARCH DETAIL