Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Acta cir. bras ; 23(2): 140-148, Mar.-Apr. 2008. ilus, graf
Article in English | LILACS | ID: lil-478750

ABSTRACT

PURPOSE: To study the repair of bone defect filled with autograft or bovine bone devitalized matrix in rats under anti-inflammatory action. METHODS: Two hundred and forty Wistar rats were distributed to two groups of 120 animals each. A 2mm-diameter defect was created in the femoral diaphysis. Animals of Group I had the bone defect filled with autograft and those of Group II, with bovine bone devitalized matrix. Animals of each group were redistributed to four subgroups according to the intramuscular administration of anti-inflammatory drug or saline solution: A - diclofenac sodium; B - dexamethasone; C - meloxicam; D - saline solution. Evaluation periods were 7, 14 and 30 days. Histological evaluation consisted of quantifying the inflammatory process, the bone neoformation, the collagen formation and the presence of macrophages. RESULTS: Animals of Group I did not show significant difference considering inflammatory reaction. Significant and progressive increase of bone neoformation was observed in both groups. The animals that received meloxicam and autograft showed less collagen formation at 14 and 30 days. The number of macrophages was higher in Group II than in Group I. The animals treated with dexamethasone and saline solution did not show statistically significant difference. CONCLUSIONS: Diclofenac sodium and meloxicam delayed bone graft repair and dexamethasone did not interfere in it.


OBJETIVO: Estudar o reparo do defeito ósseo preenchido com enxerto ósseo autógeno ou matriz óssea bovina desvitalizada sob ação de antiinflamatórios em ratos. MÉTODOS: 240 ratos Wistar, distribuídos em dois grupos de 120 animais. Confeccionou-se defeito de 2 mm de diâmetro na diáfise femoral. Os animais do Grupo I tiveram o defeito ósseo preenchido com enxerto ósseo autógeno e os do Grupo II com matriz óssea bovina desvitalizada. Cada grupo foi redistribuído em quatro subgrupos segundo a administração intramuscular de antiinflamatório ou solução salina: A - diclofenaco de sódio; B - dexametasona; C - meloxicam; D - solução salina. Os períodos de avaliação foram de 7, 14 e 30 dias. A avaliação histológica constou da quantificação do processo inflamatório, osso neoformado, formação de colágeno e macrófagos. RESULTADOS: Os animais do Grupo I não mostraram diferença significante em relação à reação inflamatória. Observou-se aumento significante e progressivo da neoformação óssea nos Grupos I e II. Os animais que receberam meloxicam e enxerto autógeno mostraram menor aporte de colágeno aos 14 e 30 dias de observação. Os macrófagos apresentaram-se em maior quantidade no Grupo II que no Grupo I. Os animais tratados com dexametasona e solução salina não demonstraram diferença estatisticamente significante entre os Grupos I e II. CONCLUSÕES: O diclofenaco de sódio e o meloxicam retardam a reparação do enxerto ósseo. A dexametasona não interfere na reparação do enxerto ósseo.


Subject(s)
Animals , Cattle , Male , Rats , Anti-Inflammatory Agents/pharmacology , Bone Transplantation , Dexamethasone/pharmacology , Diclofenac/pharmacology , Osseointegration/drug effects , Thiazines/pharmacology , Thiazoles/pharmacology , Rats, Wistar , Time Factors
2.
Acta cir. bras ; 21(supl.4): 57-62, 2006. tab
Article in English | LILACS | ID: lil-440781

ABSTRACT

PURPOSE: The aim of this study was to analyse the surface of titanium implants using disc irradiated with lasers. METHODS: Titanium discs were irradiated with laser high insensitive (Nd-YAG), deposited durapatite and used thermal treatment. Sample received qualitative morphological analyse trough micrographics with many size in SEM (Scanning Electron Microscopy). RESULTS: Surface laser irradiation shows roughness and isomorphic characteristic. The durapatite amplified the titanium surface area by method biomimetic. CONCLUSION: The surface treatment presented more deposition of durapatite, roughness on the surface, better isomorphic characteristic and increase quantitative in titanium surface area, samples shows rugous, roughness and homogeneity there is not found in the implants available at the market.


OBJETIVO: Estudar a superfície de implantes osseointegráveis utilizando discos de titânio irradiados com feixe de laser. MÉTODOS: A amostra foi irradiada com feixes de laser de alta intensidade (Nd-YAG), posteriormente depositado hidróxiapatita e submetido a tratamento térmico. Foi analisada sob MEV (Microscópio Eletrônico de Varredura) e realizada análise morfológica qualitativa com microfotografias em vários aumentos. RESULTADOS: A superfície irradiada com laser apresentou deformidade superficial e característica isomórfica; a aplicação de hidroxiapatita pelo método de biomimético aumentou quantitativamente a área da superfície de titânio. CONCLUSÃO: A deposição de hidroxiapatita apresentou melhor característica isomórfica e aumento quantitativo da área superficial estudada, a amostra demonstrou características não encontradas nos implantes disposto no mercado.


Subject(s)
Biocompatible Materials , Durapatite , Dental Implants/standards , Lasers , Materials Testing , Titanium/radiation effects , Microscopy, Electron, Scanning , Surface Properties/radiation effects
SELECTION OF CITATIONS
SEARCH DETAIL