Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Journal of Gynecologic Oncology ; : e1-2019.
Article in English | WPRIM | ID: wpr-719243

ABSTRACT

OBJECTIVE: There is no definitive guideline for the significance and cut-off value of squamous-cell carcinoma antigen (SCC-Ag) in cervical cancer. Thus, we analyzed the significance and optimal cut-off value of SCC-Ag for predicting tumor recurrence and patient survival in squamous-cell carcinoma of uterine cervix. METHODS: From January 2010 to October 2016, we enrolled 304 cervical cancer patients with squamous-cell carcinoma staging International Federation of Gynecology and Obstetrics (FIGO) Ib–IVa and treated with definitive chemoradiotherapy (CRT) followed by intra-cavitary radiotherapy (ICR). The cut-off value of SCC-Ag level for tumor recurrence was calculated using the receiver operating characteristic (ROC) curve. The recurrence-free survival (RFS) and overall survival (OS) were assessed using Kaplan-Meier method to estimate the significance of SCC-Ag level. RESULTS: The optimal cut-off value of SCC-Ag level for predicting tumor recurrence was calculated and set at 4.0 ng/mL in the ROC curve. After a median follow-up period of 36.5 months, the 3-year RFS (56.6% vs. 80.2%, p < 0.001) and OS (72.1% vs. 86.8%, p=0.005) were significantly lower in SCC-Ag ≥4 ng/mL arm than in < 4 ng/mL arm. The 3-year locoregional recurrence (17.6% vs. 7.0%, p=0.012), distant metastasis (20.4% vs. 6.9%, p=0.002), and para-aortic recurrence (9.4% vs. 2.1%, p=0.012) rates were significantly higher in SCC-Ag ≥4 ng/mL arm than in SCC-Ag < 4 ng/mL arm. CONCLUSION: Pre-treatment SCC-Ag level higher than 4 ng/mL may be a useful predictor of tumor recurrence in patients with squamous-cell carcinoma of uterine cervix treated with definitive CRT and ICR.


Subject(s)
Female , Humans , Arm , Cervix Uteri , Chemoradiotherapy , Follow-Up Studies , Gynecology , Methods , Neoplasm Metastasis , Obstetrics , Radiotherapy , Recurrence , ROC Curve , Uterine Cervical Neoplasms
2.
Radiation Oncology Journal ; : 340-348, 2017.
Article in English | WPRIM | ID: wpr-52738

ABSTRACT

PURPOSE: To evaluate the diagnostic accuracy of computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography/computed tomography (PET/CT) in predicting pelvic lymph node (LN) metastases in patients with cervical cancer. MATERIALS AND METHODS: From January 2009 to March 2015, 114 patients with FIGO stage IA1-IIB uterine cervical cancer who underwent hysterectomy with pelvic lymphadenectomy and took CT, MRI, and PET/CT before surgery were enrolled in this study. The criteria for LN metastases were a LN diameter ≥1.0 cm and/or the presence of central necrosis on CT, a LN diameter ≥1.0 cm on MRI, and a focally increased FDG uptake on PET/CT. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for pelvic LN metastases were estimated. RESULTS: The sensitivity, specificity, PPV, NPV, and accuracy for detection of pelvic LN metastases were 51.4%, 85.9%, 41.3%, 90.1%, and 80.3% for CT; 24.3%, 96.3%, 56.3%, 86.8%, and 84.6% for MRI; and 48.6%, 89.5%, 47.4%, 90.0%, and 82.9% for PET/CT, respectively. The sensitivity of PET/CT and CT was higher than that of MRI (p=0.004 and p= 0.013, respectively). The specificity of MRI was higher than those of PET/CT and CT (p=0.002 and p=0.001, respectively). The difference of specificity between PET/CT and CT was not statistically significant (p=0.167). CONCLUSION: These results indicate that preoperative CT, MRI, and PET/CT showed low to moderate sensitivity and PPV, and moderate to high specificity, NPV, and accuracy. More efforts are necessary to improve sensitivity of imaging modalities in order to predict pelvic LN metastases.


Subject(s)
Humans , Electrons , Hysterectomy , Lymph Node Excision , Lymph Nodes , Magnetic Resonance Imaging , Necrosis , Neoplasm Metastasis , Positron-Emission Tomography , Positron Emission Tomography Computed Tomography , Sensitivity and Specificity , Uterine Cervical Neoplasms
3.
Cancer Research and Treatment ; : 774-780, 2015.
Article in English | WPRIM | ID: wpr-74286

ABSTRACT

PURPOSE: This study investigated setup error and effectiveness of weekly image-guided radiotherapy (IGRT) of TomoDirect for early breast cancer. MATERIALS AND METHODS: One hundred and fifty-one breasts of 147 consecutive patients who underwent breast conserving surgery followed by whole breast irradiation using TomoDirect in 2012 and 2013 were evaluated. All patients received weekly IGRT. The weekly setup errors from simulation to each treatment in reference to chest wall and surgical clips were measured. Random, systemic, and 3-dimensional setup errors were assessed. Extensive setup error was defined as 5 mm above the margin in any directions. RESULTS: All mean errors were within 3 mm of all directions. The mean angle of gantry shifts was 0.6degrees. The mean value of absolute 3-dimensional setup error was 4.67 mm. In multivariate analysis, breast size (odds ratio, 2.82; 95% confidence interval, 1.00 to 7.90) was a significant factor for extensive error. The largest significant deviation of setup error was observed in the first week of radiotherapy (p < 0.001) and the deviations gradually decreased with time. The deviation of setup error was 5.68 mm in the first week and within 5 mm after the second week. CONCLUSION: In this study, there was a significant association between breast size and significant setup error in breast cancer patients who received TomoDirect. The largest deviation occurred in the first week of treatment. Therefore, patients with large breasts should be closely observed on every fraction and fastidious attention is required in the first fraction of IGRT.


Subject(s)
Humans , Breast Neoplasms , Breast , Mastectomy, Segmental , Multivariate Analysis , Radiotherapy , Radiotherapy Setup Errors , Radiotherapy, Image-Guided , Surgical Instruments , Thoracic Wall
4.
Radiation Oncology Journal ; : 206-215, 2013.
Article in English | WPRIM | ID: wpr-115566

ABSTRACT

PURPOSE: Re-irradiation (re-RT) is considered a treatment option for inoperable locoregionally recurrent head and neck cancer (HNC) after prior radiotherapy. We evaluated the efficacy and safety of re-RT using Helical Tomotherapy as image-guided intensity-modulated radiotherapy in recurrent HNC. MATERIALS AND METHODS: Patients diagnosed with recurrent HNC and received re-RT were retrospectively reviewed. Primary endpoint was overall survival (OS) and secondary endpoints were locoregional control and toxicities. RESULTS: The median follow-up period of total 9 patients was 18.7 months (range, 4.1 to 76 months) and that of 3 alive patients was 49 months (range, 47 to 76 months). Median dose of first radiotherapy and re-RT was 64.8 and 47.5 Gy10. Median cumulative dose of the two courses of radiotherapy was 116.3 Gy10 (range, 91.8 to 128.9 Gy10) while the median interval between the two courses of radiation was 25 months (range, 4 to 137 months). The response rate after re-RT of the evaluated 8 patients was 75% (complete response, 4; partial response, 2). Median locoregional relapse-free survival after re-RT was 11.9 months (range, 3.4 to 75.1 months) and 5 patients eventually presented with treatment failure (in-field failure, 2; in- and out-field failure, 2; out-field failure, 1). Median OS of the 8 patients was 20.3 months (range, 4.1 to 75.1 months). One- and two-year OS rates were 62.5% and 50%, respectively. Grade 3 leucopenia developed in one patient as acute toxicity, and grade 2 osteonecrosis and trismus as chronic toxicity in another patient. CONCLUSION: Re-RT using Helical Tomotherapy for previously irradiated patients with unresectable locoregionally recurrent HNC may be a feasible treatment option with long-term survival and acceptable toxicities.


Subject(s)
Humans , Follow-Up Studies , Head and Neck Neoplasms , Head , Osteonecrosis , Radiotherapy , Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated , Retrospective Studies , Treatment Failure , Trismus
SELECTION OF CITATIONS
SEARCH DETAIL