Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
The Korean Journal of Internal Medicine ; : 793-796, 2020.
Article | WPRIM | ID: wpr-831787

ABSTRACT

There are limited data on the duration of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in respiratory specimens after resolution of coronavirus disease 2019 (COVID-19)-associated symptoms/signs. We determined duration of SARS-CoV-2 virus shedding in symptomatic patients after remission of symptoms. We investigated the duration of SARS-CoV-2 RNA detection using real-time reverse transcriptase polymerase chain reaction for SARS-CoV-2 in nasopharyngeal/oropharyngeal swabs or sputum or saliva. Six patients were included in the final analysis. The median (range) duration of SARS-CoV-2 viral detection after hospitalization was 34 days (22 to 67). After resolution of symptoms/signs, SARS-CoV-2 RNA was detected for median (range) of 26 days (9 to 48). Among the six patients, one had persistent detection of SARS-CoV-2 RNA until day 67 of hospitalization, which was 30 days after symptom resolution. This case represents the longest duration of SARS-CoV-2 detection, and highlights the need for long-term follow up of COVID-19 patients despite resolution of symptoms to confirm SARS-CoV-2 clearance.

2.
Annals of Laboratory Medicine ; : 49-54, 2016.
Article in English | WPRIM | ID: wpr-37150

ABSTRACT

BACKGROUND: Recent advances in laboratory information systems have largely been focused on automation. However, the phlebotomy services have not been completely automated. To address this issue, we introduced an automated reception and turnaround time (TAT) management system, for the first time in Korea, whereby the patient's information is transmitted directly to the actual phlebotomy site and the TAT for each phlebotomy step can be monitored at a glance. METHODS: The GNT5 system (Energium Co., Ltd., Korea) was installed in June 2013. The automated reception and TAT management system has been in operation since February 2014. Integration of the automated reception machine with the GNT5 allowed for direct transmission of laboratory order information to the GNT5 without involving any manual reception step. We used the mean TAT from reception to actual phlebotomy as the parameter for evaluating the efficiency of our system. RESULTS: Mean TAT decreased from 5:45 min to 2:42 min after operationalization of the system. The mean number of patients in queue decreased from 2.9 to 1.0. Further, the number of cases taking more than five minutes from reception to phlebotomy, defined as the defect rate, decreased from 20.1% to 9.7%. CONCLUSIONS: The use of automated reception and TAT management system was associated with a decrease of overall TAT and an improved workflow at the phlebotomy room.


Subject(s)
Automation, Laboratory , Efficiency, Organizational/standards , Phlebotomy/statistics & numerical data , Republic of Korea , Time Factors , Workflow
3.
Annals of Laboratory Medicine ; : 223-229, 2014.
Article in English | WPRIM | ID: wpr-163730

ABSTRACT

BACKGROUND: Most immune reactions related to transfusion and transplantation are caused by IgM ABO antibodies. However, IgG also plays an important role in these reactions. Therefore, a method to measure antibodies, including IgG, is necessary. We investigated ABO antibody titers of healthy individuals using a column agglutination technique (CAT) with or without dithiothreitol (DTT) and compared them with titers obtained using a conventional tube method. METHODS: Among healthy adults who underwent a medical examination, 180 individuals (60 with blood group A, 60 with group B, and 60 with group O) were selected. Antibody titrations were performed using the immediate spin (IS) tube, anti-human globulin (AHG) tube, and CAT with or without DTT methods. RESULTS: Higher median values of anti-B and anti-A titers in groups A and B individuals, respectively, were obtained using the IS method than using the AHG method. Higher values for group O individuals were obtained using the AHG method. Higher median titers of anti-B and anti-A in group O individuals were obtained using CAT without DTT than using the AHG method. Median titers of anti-B and anti-A in all blood groups were higher in CAT without DTT than in CAT with DTT, especially for group O individuals. CONCLUSIONS: We recommend CAT with and without DTT for titration of anti-A and anti-B, especially in group O individuals, to provide more sensitive results that include IgG data. Adjustment of insurance coverage of fees associated with antibody titration might be necessary, considering the actual cost of reagents and personnel.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , ABO Blood-Group System/immunology , Agglutination Tests/instrumentation , Antibodies/analysis , Immunoglobulin G/immunology
SELECTION OF CITATIONS
SEARCH DETAIL