Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
2.
Arq. bras. oftalmol ; 76(4): 226-228, jul.-ago. 2013. ilus, graf
Article in English | LILACS | ID: lil-686558

ABSTRACT

PURPOSE: To relate the outcomes of 7 eyes of 7 patients in which a dexamethasone 0.7 mg implant (Ozurdex®) was placed inside the capsule bag after phacoemulsification and intraocular lens (IOL) implantation and compare with the fellow eyes, that were operated by the same technique and received dexamethasone eyedrops in the post-operatory. METHODS: Report review of 7 eyes of 7 patients who received dexamethasone 0.7 mg implant after phacoemulsification and IOL, comparing them to the fellow eyes. All the patients underwent bilateral cataract surgery, with one month interval, by the same technique and by experienced surgeons, without complications. Post operatory medication consisted of moxifloxacin eye drops for all the 14 eyes and topic dexamethasone for the 7 eyes that did not received the implant. RESULTS: Nuclear cataract classification (according to LOCS III) was 3.28 ± 0.69 in the implant eye group and 3.14 ± 0.83 in the fellow eye group. Postoperative best spectacle correct visual acuity (BSCVA) was 0.85 ± 0.12 and 0.87 ± 0.13, respectively in the implant and fellow eye groups. The intraocular pressure remained stable and similar to the pre-operative measurements. Anterior chamber reaction and cornea edema were similar in both groups in the follow-up. Two of the four no sutured pellet migrated to the anterior chamber during the first post-operative week and had to be repositioned. Another no sutured pellet dislocated and remained partially inside the capsule bag. The 3 patients with IOL haptic-sutured pellet had no complications. CONCLUSIONS: In the present study, dexamethasone 0.7mg implant were effective in controlling the inflammation after phacoemulsification and IOL implantation, with no significant side effects.


OBJETIVOS: Relatar os resultados de 7 olhos de 7 pacientes em que foi realizado o implante de dexametasona 0,7 mg (Ozurdex®) no saco capsular após facoemulsificação e implante de lente intraocular (LIO) e comparar com os olhos contralaterais, que foram operados pela mesma técnica e receberam colírio de dexametasona no pós-operatório. MÉTODOS: Relato de casos de 7 olhos de 7 pacientes que receberam o implante de dexametasona 0,7 mg após facoemulsificação e implante de LIO, comparando-os com os olhos contralaterais. Todos os pacientes foram submetidos a cirurgia de catarata bilateral, com intervalo de um mês entre as cirurgias, pela mesma técnica, por cirurgiões experientes e sem complicações. No pós-operatório foi utilizado colírio de moxifloxacino em todos os 14 olhos e dexametasona tópica nos olhos que não receberam o implante. RESULTADOS: A classificação da catarata de acordo com o LOCS III foi de 3,28 ± 0,69 no grupo que recebeu o implante e 3,14 ± 0,83 no grupo de olhos contralateral. A acuidade visual com melhor correção foi de 0,85 ± 0,12 e 0,87 ± 0,13 respectivamente nos grupos com e sem implante. A pressão intraocular permaneceu estável e similar aos valores pré-operatórios. A reação de câmara anterior e o edema de córnea foram similares nos dois grupos. Dois dos 4 implantes sem sutura migraram para a câmara anterior durante a primeira semana de pós-operatório e necessitaram de reposicionamento. Outro implante sem sutura teve deslocamento e permaneceu parcialmente dentro do saco capsular. Os 3 pacientes com implante suturado não tiveram complicações. CONCLUSÃO: No presente estudo, o implante de dexametasona 0,7 mg foi efetivo no controle da inflamação intraocular após cirurgia de facoemulsificação e implante de LIO, sem efeitos colaterais significativos.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Anti-Inflammatory Agents/administration & dosage , Dexamethasone/administration & dosage , Lens Implantation, Intraocular/methods , Phacoemulsification/methods , Postoperative Complications/prevention & control , Administration, Ophthalmic , Anterior Chamber/drug effects , Drug Implants , Postoperative Complications/drug therapy , Time Factors , Treatment Outcome , Visual Acuity
3.
Arq. bras. oftalmol ; 73(6): 517-520, nov.-dez. 2010. graf, tab
Article in Portuguese | LILACS | ID: lil-572216

ABSTRACT

Objetivo: Analisar os resultados obtidos com a aplicação do programa de ensino de facoemulsificação CBO/ALCON no curso de especialização em oftalmologia do Hospital de Olhos do Paraná. Métodos: Realizou-se um estudo retrospectivo analítico dos resultados das cirurgias de catarata realizadas pelo programa de ensino de facoemulsificação CBO/ALCON que utiliza o método "reverso" em pacientes provenientes do ambulatório do SUS do Hospital de Olhos do Paraná. O programa consta da progressão dos alunos por cinco etapas chamadas de "check points", sendo analisadas as intercorrências per-operatórias em cada um deles, bem como as pós-operatórias. Resultados: Do total de 84 olhos operados, 77 (91,67 por cento) apresentaram acuidade visual (AV) final de 20/40 ou melhor. Entre as intercorrências, a principal delas foi a rotura de cápsula posterior (RCP) e ocorreu em 11 (13,09 por cento) dos 13 (15,48 por cento) olhos que apresentaram algum tipo de complicação. Conclusão: O método "reverso" proposto para o ensino de facoemulsificação pelo programa CBO/ALCON se mostra uma forma de ensino adequada, para o médico residente e seu instrutor, e principalmente para o paciente, devido ao baixo índice de complicações.


Purpose: To analyze the results obtained with a new phacoemulsification teaching method in the specialization course of Hospital de Olhos do Paraná. Methods: A retrospective study evaluated the results of a "reversal" method used in the CBO/ALCON teaching program at the Hospital de Olhos do Paraná. The method is based on the student progression through five checkpoints starting from the end of the surgery towards the beginning and analysis of intra- and postoperative complications at each one of the checkpoints. Results: Of 84 operated eyes, 77 (91.67 percent) presented final visual acuity of 20/40 or better. Among the complications, the main one was the posterior capsular rupture and occurred in 11 (13.09 percent) of 13 (15.48 percent) eyes with complications. Conclusion: The "reversal" teatching method used in the CBO/ALCON teaching program is appropriate to the student, his instructor, as well as to the patient.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Phacoemulsification/education , Specialization/standards , Teaching/methods , Brazil , Clinical Competence/statistics & numerical data , Intraoperative Complications , Postoperative Complications , Phacoemulsification/adverse effects , Phacoemulsification/methods , Retrospective Studies , Treatment Outcome , Visual Acuity
4.
Arq. bras. oftalmol ; 72(2): 189-193, mar.-abr. 2009. graf, tab
Article in English | LILACS | ID: lil-513887

ABSTRACT

Purpose: To evaluate the prediction of refraction using the SRK/T formula for intraocular lens (IOL) calculation in eyes with medium axial length after phacoemulsification. Methods: This prospective study enrolled 33 eyes with nuclear cataract that underwent phacoemulsification. All procedures were performed by one surgeon with theintraocular lens placed within the capsular bag. The same technician whowas unaware of the purpose of the study made all the measurements. Theachieved refractive error one month after surgery was compared to the predicted postoperative refractive error by the SRK/T formula. Results: The ocular axial length varied between 22.2 mm and 24.5 mm. The mean predicted refraction was -0.431 ± 0.181 D and the mean achieved postoperative spherical equivalent was -0.220 ± 0.732 D. Eighteen eyes (55%) had a refractive error between ± 0.50 D and thirty eyes (91%) between ± 1.00 D of the predicted refraction. There was a tendency toward hyperopic shift (mean ± SD: 0.211 ± 0.708 D, p=0.009). Conclusion: The SRK/T formula demonstrated a satisfactory accuracy to calculate the error of refraction in eyes with medium axial length.


Objetivo: Avaliar resultados refracionais utilizando a fórmula SRK/T no cálculo de lentes intraoculares (LIO) em olhos comcomprimento axial médio após facoemulsificação. Métodos: Este estudo prospectivo envolveu 33 olhos com catarata nuclear que foram submetidos a facoemulsificação. Todas as cirurgias foram realizadas pelo mesmo cirurgião com lentes intraoculares no saco capsular. O mesmo tecnólogo, o qualnão sabia o objetivo do estudo, realizou todas as medidas biométricas. O erro refracional atingido um mês após a cirurgia foi comparado ao erro refracional pós-operatório previsto pelafórmula SRK/T. Resultados: O comprimento axial variou entre 22,2 mm e 24,5 mm. A refração média prevista foi -0,431 ± 0,181 dioptrias (D) e o equivalente esférico pós-operatório alcançado foi -0,220 ± 0,732 D. Dezoito olhos (55%) obtiveram errorefracional de ± 0,50 D e 30 olhos (91%) entre ± 1,00 D da refração prevista. Houve tendência a um erro hipermetrópico (média±SD: 0,211 ± 0,708 D, p=0,009). Conclusão: A fórmula SRK/T demonstrou acurácia satisfatória no cálculo do erro refracional em olhos de comprimento axial médio.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Lens Implantation, Intraocular , Phacoemulsification/methods , Predictive Value of Tests , Prospective Studies , Refractometry , Reproducibility of Results , Treatment Outcome , Visual Acuity
5.
Arq. bras. oftalmol ; 70(4): 633-637, jul.-ago. 2007. tab
Article in Portuguese | LILACS | ID: lil-461953

ABSTRACT

OBJETIVO: Analisar a relevância da avaliação pré-operatória na prevenção de eventos clínicos adversos per e pós-operatórios na cirurgia de catarata. MÉTODOS: Foram incluídos no estudo 1.254 pacientes submetidos à cirurgia de catarata no Instituto da Catarata do Departamento Oftalmologia UNIFESP-EPM, no período de jan-dez 2004. Dados referentes à avaliação pré-operatória e à ocorrência de eventos clínicos adversos relacionados ao procedimento anestésico/cirúrgico foram retrospectivamente coletados. RESULTADOS: Dezesseis pacientes (1,2 por cento) apresentaram evento clínico adverso. Novecentos e trinta e seis pacientes (74,6 por cento) apresentaram pelo menos um exame alterado, porém este fator não mostrou associação com a ocorrência de evento clínico adverso (p=0,334). CONCLUSÃO: Na série estudada a alteração de exames laboratoriais, eletrocardiograma e/ou radiografia de tórax não se correlacionou com a ocorrência de eventos clínicos adversos relacionados ao procedimento anestésico/cirúrgico.


PURPOSE: Analysis of the relevance of preoperative evaluation to prevent adverse clinical events, pre- and postoperative, on cataract surgery. METHODS: The study includes 1254 patients submitted to cataract surgery at the Instituto da Catarata do Departamento de Oftalmologia da UNIFESP - EPM, in the period of Jan - Dec 2004. Data referring to the preoperative evaluation and adverse clinical events related to anesthesia/surgical procedure were retrospectively collected. RESULTS: Sixteen patients (1.2 percent) showed an adverse clinical event. Nine hundred thirty-six patients (74.6 percent) showed at least one altered examination. This factor, nevertheless, did not show any relation to the adverse clinical event (p=0.334). CONCLUSION: Concerning the studied series, the altered laboratory tests, electrocardiogram and/or thorax x-ray has no correlation with the adverse clinical events related to the anesthesia/surgical procedure.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Anesthesia/adverse effects , Cataract Extraction/adverse effects , Diagnostic Tests, Routine , Preoperative Care , Postoperative Complications/prevention & control , Brazil/epidemiology , Epidemiologic Methods , Postoperative Complications/epidemiology
6.
Arq. bras. oftalmol ; 70(3): 544-546, maio-jun. 2007. ilus
Article in English | LILACS | ID: lil-459849

ABSTRACT

To report a case of nonarteritic anterior ischemic optic neuropathy (NAION) after uneventful cataract extraction and intraocular lens implantation. Prospective, observational case report and literature review. We report the case history of a 74-year-old woman who underwent phacoemulsification and developed sudden loss of vision on the 13th postoperative day. After complete ocular and systemic evaluation the diagnosis of NAION was made. NAION can be associated with cataract extraction, and surgeons should be aware of this potentially blinding complication.


Os autores relatam um caso de neuropatia óptica isquêmica anterior (NOIA) não-arterítica após facoemulsificação de rotina e implante de lente intra-ocular. Uma paciente de 74 anos do sexo feminino foi submetida à cirurgia de catarata pela técnica de facoemulsificação e desenvolveu perda súbita e grave de visão no décimo terceiro dia pós-operatório. Após extensa investigação clínica e laboratorial, ocular e sistêmica, foi feito o diagnóstico de NOIA não-arterítica. Feita revisão da literatura, encontrando-se descrição desta complicação em raros casos associada a facectomia e implante de lente intra-ocular.


Subject(s)
Aged , Female , Humans , Blindness/etiology , Optic Neuropathy, Ischemic/etiology , Phacoemulsification/adverse effects , Acute Disease , Optic Neuropathy, Ischemic/diagnosis
7.
Arq. bras. oftalmol ; 69(5): 725-729, set.-out. 2006. graf, tab
Article in English, Portuguese | LILACS | ID: lil-439321

ABSTRACT

PURPOSE: To evaluate the influence of a blue light spectrum filter (BLSF), similar in light spectrum transmittance to the intraocular lens Acrysof NaturalTM, on standard automated perimetry (SAP) and short-wavelength automated perimetry (SWAP). METHODS: Twenty young individuals (<30 y.o.), without any systemic or ocular alterations (twenty eyes) underwent a random sequence of four Humphrey visual field tests: standard automated perimetry (SAP) and short-wavelength automated perimetry (SWAP) with and without a blue light spectrum filter. All patients had intraocular pressure lower than 21 mmHg, normal fundus biomicroscopy, and no crystalline lens opacity. Foveal threshold (FT), mean deviation (MD), and pattern standard deviation (PSD) indexes obtained from the visual field tests and the difference caused by eccentricity in short-wavelength automated perimetry examinations were analyzed using paired t test. Interindividual variability (standard deviation) was calculated using Pitman's test for correlated samples. RESULTS: Statistically significant reductions in the mean deviation (p<0.001) and in the foveal threshold (p<0.001) measured by short-wavelength automated perimetry with the use of the blue light spectrum filter in comparison to short-wavelength automated perimetry without the use of the blue light spectrum filter were observed, but not in standard automated perimetry exams. No other parameters showed statistically significant differences in the short-wavelength automated perimetry and standard automated perimetry tests. Interindividual standard deviation of the test points in the short-wavelength automated perimetry exams increased with eccentricity both with and without the use of the blue light spectrum filter, as sensitivity for inferior and superior hemifields (inferior hemifield minus superior hemifield), but no statistically significant difference in the variability when comparing the use or not of the blue light spectrum filter was noted. When comparing...


OBJETIVO: Avaliar a influência de um filtro para o espectro azul da luz, semelhante à lente intra-ocular Acrysof Natural®, nos exames de perimetria automatizada padrão (branco-no-branco) e de comprimento de onda curto (azul-no-amarelo). MÉTODOS: Vinte pacientes jovens sem alterações oculares (20 olhos) realizaram seqüência de 4 exames de campo visual: perimetria automatizada padrão e azul-no-amarelo com e sem o filtro para o espectro azul da luz. Os índices de limiar foveal (FT), desvio médio (MD) e desvio-padrão (PSD) obtidos em todos os exames e a diferença causada pela excentricidade nos exames de perimetria automatizada azul-no-amarelo foram analisados. Variabilidade interindivíduos (desvio-padrão dos pontos testados) foi calculada. RESULTADOS: Observou-se redução estatisticamente significante no desvio médio (p<0.001) e no limiar foveal (p<0.001) medidos pela perimetria automatizada azul-no-amarelo com o uso do filtro para o espectro azul da luz comparado quando realizado sem o filtro. Nenhum outro índice avaliado apresentou diferença estatisticamente significante nos exames de perimetria automatizada padrão ou azul-no-amarelo. Foi notado aumento da variabilidade interindivíduos com a excentricidade nos exames de perimetria automatizada azul-no-amarelo com e sem o uso do filtro para o espectro azul da luz, assim como a diferença de sensibilidade entre os hemisférios inferior e superior (hemisfério inferior menos superior), mas não houve diferença estatisticamente significante quando comparados os exames com e sem o uso do filtro. Quando foram comparados os 4 pontos mais inferiores e os 4 pontos mais superiores, a diferença inferior-superior aumentou com e sem o uso do filtro para o espectro azul da luz. CONCLUSÃO: Observou-se redução estatisticamente significante no desvio médio e limiar foveal nos exames de perimetria automatizada azul-no-amarelo com o uso do filtro para o espectro azul da luz, mas não nos exames de perimetria automatizada padrão.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Filtration/instrumentation , Lenses, Intraocular , Light , Visual Field Tests , Visual Fields/physiology , Color , Diagnosis, Computer-Assisted , Filtration/methods , Linear Models , Sensory Thresholds/physiology , Visual Field Tests
8.
Arq. bras. oftalmol ; 68(4): 439-443, jul.-ago. 2005. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-417781

ABSTRACT

OBJETIVO: Avaliar a sensibilidade ao contraste e a acuidade estereoscópica em pacientes pseudofácicos, que receberam implante bilateral de lente intra-ocular multifocal. MÉTODOS: Prospectivamente foram realizados testes de sensibilidade ao contraste com o uso da tabela Pelli-Robson e teste de acuidade estereoscópica com emprego do Titmus Stereo Test, em 20 pacientes com implante bilateral de lente intra-ocular multifocal Acrysof Restor®, no pós-operatório de 1 a 2 meses e sem uso de qualquer correção óptica. RESULTADOS:O teste de sensibilidade ao contraste binocular demonstrou que 6 pacientes (30 por cento) apresentaram 1,80 unid. log, 13 (65 por cento) 1,65 e 1 (5 por cento) 1,50. No teste monocular, ocorreram as seguintes respostas: 17 pacientes (85 por cento) 1,65 unid. log e 3 (15 por cento) 1,50 para o teste do olho direito. O teste do olho esquerdo mostrou que 16 pacientes (80 por cento) apresentaram 1,65 unid. log e 4 (20 por cento) 1,50. A média e o desvio-padrão da sensibilidade ao contraste testada binocularmente foi 1,69 (±0,08), ao passo que monocularmente foi 1,63 (±0,05) para OD e 1,62 (±0,06) para OE. O teste de acuidade estereoscópica revelou que 12 pacientes (60 por cento) obtiveram 40", 6 (30 por cento) 50" e 2 (10 por cento) 60", com média de 45" e desvio-padrão de ±6,88". CONCLUSAO: A lente intra-ocular empregada no estudo, proporcionou resultados de sensibilidade ao contraste e acuidade estereoscópica compatíveis e de acordo com critérios de normalidade estabelecidos anteriormente por outros estudos em grupos de pacientes fácicos e pseudofácicos, e portanto, impacto positivo na funcionalidade visual.


Subject(s)
Humans , Middle Aged , Depth Perception/physiology , Pseudophakia/physiopathology , Contrast Sensitivity/physiology , Cataract Extraction , Follow-Up Studies , Lens Implantation, Intraocular , Prospective Studies
9.
Arq. bras. oftalmol ; 67(6): 887-891, nov.-dez. 2004. tab, graf
Article in Portuguese | LILACS | ID: lil-393150

ABSTRACT

OBJETIVO: Comparar a precisão e reprodutibilidade de dois biômetros ultra-sônicos convencionais e um biômetro óptico para o cálculo da lente intra-ocular (LIO) acomodativa. MÉTODOS: Pacientes com catarata foram submetidos aos exames em 3 biômetros distintos (IOLMaster®, Axis II® e Humphrey Mod. 820®), antes da cirurgia para implantação da lente intra-ocular acomodativa de silicone (C&C Vision AT-45). No biômetro Humphrey Mod. 820 utilizou-se a técnica de contato e o Axis II foi usado para as técnicas de contato e imersão. O método de interferometria óptica foi realizado pelo IOLMaster. O comprimento axial (AL), profundidade da câmara anterior (ACD) e a ceratometria corneana (K) foram os parâmetros oculares analisados. RESULTADOS: Foram submetidos aos exames 34 pacientes com média de idade de 70,6 anos e idade variando entre 53 e 90 anos. A menor média do comprimento axial (23,12 mm), foi obtida no Axis II (contato) e maior (23,21 mm) no Humphrey Mod. 820 (contato). A maior média da profundidade da câmara anterior (3,10 mm) no IOLMaster e a menor (2,97 mm) no Humphrey Mod. 820 (contato). A reprodutibilidade para os dados de comprimento axial foi significativamente grande para todos os biômetros [3,02 por cento, 3,07 por cento e 3,19 por cento respectivamente para Humphrey Mod. 820 e Axis II (imersão), Axis II (contato) e IOLMaster]. Os biômetros foram extremamente concordantes nas medidas dos parâmetros analisados (99,01 por cento e 94,77 por cento respectivamente para o comprimento axial e ceratometria corneana). Os coeficientes de Pearson (r) demonstraram alta correlação entre os aparelhos nas medidas do comprimento axial e profundidade da câmara anterior. CONCLUSAO: Os métodos do estudo para o cálculo da lente intra-ocular acomodativa, demonstraram que houve precisão e reprodutibilidade dos resultados, podendo evitar insatisfação visual do paciente no pós-operatório da cirurgia de catarata decorrente de erros no cálculo da lente intra-ocular.


Subject(s)
Middle Aged , Humans , Biometry/methods , Cataract/diagnosis , Interferometry/methods , Lenses, Intraocular , Reproducibility of Results
10.
Rev. bras. oftalmol ; 63(7/8): 392-397, jul.-ago. 2004. tab, graf
Article in Portuguese | LILACS | ID: lil-409676

ABSTRACT

Objetico: Nosso estudo objetiva avaliar o exame de ultrasonografia ocular em pacientes com catarata densa, como instrumento para evitar ineficiência de alocação de recursos econômicos em cirurgias com prognóstico reservado. Local: Departamento de Oftalmologia/UNIFESP - Setor de Ultra-sonografia ocular. Método: Avaliação retrospectiva do laudo de ultra-sonografia ocular de 1018 olhos de 865 pacientes, submetidos a avaliação pré-cirurgica de catarata. A tabela de procedimentos APAC/AINH - SUS 2001-2002 foi utilizada para a coleta dos valores dos procedimentos de ultra-sonografia ocular, cirurgia de catarata extracapsular, facoemulsificação e vitrectomia via pars plana (VVPP). Resultados: Odescolamento de retina foi mais frequente em olhos de pacientes com idade entre 18-50 anos (15,9 por cento do total de descolamentos de retina) do que em pacientes com mais de 50 anos (4 por cento). O valor total do pagamento efetuado pelo SUS pelos 1018 exames de ultra-sonografia, realizados na amostra estudada, foi de R$ 12.562,12. Os valores direcionados ao pagamento de cirurgias de catarata em olhos com descolamento de retina alcançariam R$ 28.352,00 (extracapsular) e R$41.152,00 (facoemulsificação). Evidencia-se, através deste estudo, que o valor de R$ 12.562,12 relativo ao pagamento do total de exames de US realizados em 101 olhos é bastante inferior (30,5 por cento no caso de FACO e 44,3 no caso de FEC) aos valores anteriormente mencionados para a realização da cirurgia de catarata em olhos com descolamento de retina e prognóstico reservado. Conclusão: A ultra-sonografia antecedendo a cirurgia de catarata densa é altamente recomendável para analisar o prognóstico e orientar quanto α melhor solução cirúrgica para cada caso, economizando recursos e preservando a boa prática médica.


Subject(s)
Male , Female , Adolescent , Adult , Middle Aged , Cataract Extraction , Cataract , Process Optimization , Health Resources/economics , Unified Health System , Retinal Detachment/diagnosis , Epidemiology, Descriptive , Prognosis , Retrospective Studies
11.
Arq. bras. oftalmol ; 67(3): 469-474, maio-jun. 2004. graf
Article in Portuguese | LILACS | ID: lil-361701

ABSTRACT

OBJETIVO: Avaliar a função visual e satisfação dos pacientes submetidos à cirurgia de catarata com implante de lente intra-ocular acomodativa e o impacto na sua qualidade de vida. MÉTODOS: Retrospectivamente, foram avaliados questionários aplicados após um ano da cirurgia de 22 pacientes que foram incluídos num estudo clínico para avaliar segurança e eficácia de uma lente intra-ocular de silicone de câmara posterior designada para corrigir visão para longe e perto. RESULTADOS: Do total dos pacientes operados, 16 (73 por cento) eram bilaterais e 6 (27 por cento) unilaterais, com idade média de 70,2 anos. Dos pacientes com implante unilateral, 5 (83,3 por cento) declararam melhora acentuada da visão e 1 (16,7 por cento) referiu máxima melhora. Quanto ao nível de satisfação, 5 (83,3 por cento) ficaram satisfeitos e 1 (16,7 por cento) muito satisfeito com o resultado cirúrgico. A visão noturna foi declarada como sem dificuldade por 3 (50,0 por cento), pouca dificuldade por 2 (33,3 por cento) e dificuldade moderada por 1 (16,7 por cento). No grupo bilateral, 7 (43,8 por cento) consideraram excelente a qualidade da visão para perto, 7 (43,8 por cento) muito boa, 1 (6,2 por cento) adequada e 1 (6,2 por cento) ruim. A visão intermediária foi classificada como excelente por 6 (37,5 por cento), muito boa por 9 (56,3 por cento) e adequada por 1 (6,2 por cento). A qualidade da visão para longe foi considerada excelente por 9 (56,3 por cento), muito boa por 3 (43,8 por cento), adequada por 2 (12,5 por cento) e não muito boa por 2 (12,5 por cento). Em relação à visão noturna 9 (56,3 por cento) declararam não ter dificuldade alguma, 5 (31,2 por cento) pouca dificuldade e 2 (12,5 por cento) dificuldade moderada. CONCLUSÕES: Considerando a propriedade óptica da LIO, a maioria dos pacientes apresentou uma melhora considerável da função visual, sem a necessidade de correção óptica, e, portanto, com impacto positivo na qualidade de vida.


Subject(s)
Humans , Middle Aged , Cataract Extraction/methods , Lenses, Intraocular , Pseudophakia , Quality of Life , Aged, 80 and over , Surveys and Questionnaires , Retrospective Studies
12.
Säo Paulo; s.n; 2000. [176] p. ilus, tab.
Thesis in Portuguese | LILACS | ID: lil-280829

ABSTRACT

Os objetivos do presente trabalho foram identificar os glicosaminoglicanos presentes na córnea humana, analisar a síntese dos glicosaminoglicanos em córneas humanas mantidas em cultura e avaliar o efeito da remoção do epitélio sobre a síntese destes compostos em córneas mantidas em cultura. Para tal, foram utilizadas córneas do Banco de Olhos do Hospital São Paulo que foram rejeitadas para transplantes. Os glicosaminoglicanos foram extraídos após proteólise dos tecidos com papaína e identificados por uma combinação de eletroforese em gel de agarose e degradação enzimática com mucopolisacaridases bacterianas específicas. Os principais glicosaminoglicanos extraídos da córnea humana foram o queratam sulfato e o dermatam sulfato, cada um correspondendo a cerca de 50 por cento do total. Para analisar os glicosaminoglicanos sintetizados em cultura, as córneas foram mantidas em meio Fl2, por 24 horas, a 37§C, em atmosfera contendo 2,5 por cento de gás carbônico. Ao meio de cultura foi adicionado 35S-sulfato, de forma que os glicosaminoglicanos sintetizados em 24 horas fossem, então, metabolicamente marcados. OS 35S-glicosaminoglicanos foram isolados da mesma forma descrita acima, exceto que foram vistos por radioautograma e quantificados em um contador de cintilações. O principal glicosaminoglicano sintetizado foi o dermatam sulfato (72 por cento do total), seguido pelo queratam sulfato (l7 por cento). Além desses dois glicosaminoglicanos, apareceu heparam sulfato (11 por cento), que não foi identificado como constituinte da córnea por estar em pequena quantidade (abaixo do limite de detecção do método). Esses resultados sugerem que o dermatam sulfato e o heparam sulfato apresentem uma taxa de turnover maior que a do queratam sulfato. A desepitelização corneana levou a uma alteração no padrão de síntese de glicosaminoglicanos, com uma maior marcação de dermatam sulfato e uma diminuição no heparam sulfato, em relação ao controle. Este efeito foi proporcional à área da córnea desepitelizada. Para verificar quais Os glicosaminoglicanos sintetizados em cada camada celular, o epitélio, o endotélio e o estroma foram separados e os glicosaminoglicanos sintetizados em cada uma delas foram identificados. Verificou-se que os ceratócitos foram os principais responsáveis pela síntese de dermatam sulfato e queratam sulfato, enquanto as células epiteliais produziram basicamente heparam sulfato. Esta observação explica a ...(au)


Subject(s)
Cornea , Corneal Stroma , Dermatan Sulfate , Epithelium, Corneal , Glycosaminoglycans , Heparitin Sulfate , Keratan Sulfate , Proteoglycans
13.
Arq. bras. oftalmol ; 58(5): 375-8, out. 1995. ilus
Article in Portuguese | LILACS | ID: lil-260467

ABSTRACT

Um caso de Sinus Pericranii associado a uma malformação do seio sagital superior, na qual o lobo frontal apresenta sua drenagem venosa para o exterior do crânio através do próprio Sinus Pericranii, originando varizes orbitárias. O diagnóstico preciso foi obtido pelo estudo angiográfico e o tratamento foi conservador devido ao risco cirúrgico. Foi feita uma breve revisão da literatura sobre Sinus Pericranii.


Subject(s)
Humans , Female , Middle Aged , Exophthalmos/etiology , Orbit/blood supply , Sinus Pericranii/complications , Varicose Veins/diagnosis , Varicose Veins/etiology
SELECTION OF CITATIONS
SEARCH DETAIL