Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Braz. j. phys. ther. (Impr.) ; 20(6): 571-579, Nov.-Dec. 2016. tab, graf
Article in English | LILACS | ID: biblio-828306

ABSTRACT

ABSTRACT Background Reducing rearfoot eversion is a commonly desired effect in clinical practice to prevent or treat musculoskeletal dysfunction. Interventions that pull the lower limb into external rotation may reduce rearfoot eversion. Objective This study investigated whether the use of external rotation elastic bands, of different levels of stiffness, will decrease rearfoot eversion during walking. We hypothesized that the use of elastic bands would decrease rearfoot eversion and that the greater the band stiffness, the greater the eversion reduction. Method Seventeen healthy participants underwent three-dimensional kinematic analysis of the rearfoot and shank. The participants walked on a treadmill with and without high- and low-stiffness bands. Frontal-plane kinematics of the rearfoot-shank joint complex was obtained during the stance phase of walking. Repeated-measures ANOVAs were used to compare discrete variables that described rearfoot eversion-inversion: mean eversion-inversion; eversion peak; and eversion-inversion range of motion. Results The low-stiffness and high-stiffness bands significantly decreased eversion and increased mean eversion-inversion (p≤0.037) and eversion peak (p≤0.006) compared with the control condition. Both bands also decreased eversion-inversion range of motion (p≤0.047) compared with control by reducing eversion. The high-stiffness band condition was not significantly different from the low-stiffness band condition for any variables (p≥0.479). Conclusion The results indicated that the external rotation bands decreased rearfoot eversion during walking. This constitutes preliminary experimental evidence suggesting that increasing external rotation moments at the lower limb may reduce rearfoot eversion, which needs further testing.

2.
Braz. j. phys. ther. (Impr.) ; 18(6): 521-529, 09/01/2015. tab
Article in English | LILACS | ID: lil-732352

ABSTRACT

Background: Isokinetic dynamometry allows the measurement of several variables related to muscular performance, many of which are seldom used, while others are redundantly applied to the characterization of muscle function. Objectives: The present study aimed to establish the particular features of muscle function that are captured by the variables currently included in isokinetic assessment and to determine which variables best represent these features in order to achieve a more objective interpretation of muscular performance. Method: This study included 235 male athletes. They performed isokinetic tests of concentric knee flexion and extension of the dominant leg at a velocity of 60º/s. An exploratory factor analysis was performed. Results: The findings demonstrated that isokinetic variables can characterize more than muscle torque production and pointed to the presence of 5 factors that enabled the characterization of muscular performance according to 5 different domains or constructs. Conclusions: The constructs can be described by torque generation capacity; variation of the torque generation capacity along repetitions; movement deceleration capacity; mechanical/physiological factors of torque generation; and acceleration capacity (torque development). Fewer than eight out of sixteen variables are enough to characterize these five constructs. Our results suggest that these variables and these 5 domains may lead to a more systematic and optimized interpretation of isokinetic assessments. .


Subject(s)
Animals , Male , Rabbits , Indenes/toxicity , Motor Neurons/drug effects , Spinal Cord/drug effects , Chlorpromazine/pharmacology , Pentobarbital/pharmacology , Reflex/drug effects , Spinal Cord/cytology
3.
Braz. j. phys. ther. (Impr.) ; 15(2): 166-173, Mar.-Apr. 2011. ilus, tab
Article in English | LILACS | ID: lil-593960

ABSTRACT

BACKGROUND: The presence of inadequate levels of passive ankle stiffness have been associated with the occurrence of movement disorders, the development of pathological conditions and the reduction in the performance of functional activities such as walking, running and jumping. Therefore, clinical tests to evaluate ankle stiffness may be useful for the physical therapy assessment. OBJECTIVES: To investigate the concurrent validity and the intra- and inter-examiner reliability of clinical measures developed to assess passive stiffness of the ankle joint during dorsiflexion movement. METHODS: Fifteen healthy participants underwent to test-retest evaluations of their ankles by two examiners. Two clinical measures were performed: 'position of first detectable resistance' and 'change in passive resistance torque'. The results of these tests were compared to the passive stiffness measured with an isokinetic dynamometer, in which the electromyography activity of specific muscles was monitored to ensure that the test was performed passively (gold standard measure). RESULTS: Pearson correlation coefficients ranged from r=-0.81 to -0.88 (p<0.001) for the correlation between the passive ankle stiffness measured with the isokinetic dynamometer and the results of the clinical measure 'position of the first detectable resistance'. For the measure of 'change in passive resistance torque', these coefficients ranged from r=0.72 to 0.83 (p<0.004). The Intraclass Correlation Coefficients (ICCs) for the intra- and inter-examiner reliability ranged from 0.75 to 0.98. CONCLUSION: The clinical measures presented satisfactory validity and reliability to be used in clinical practice.


CONTEXTUALIZAÇÃO: Níveis inadequados de rigidez passiva do tornozelo têm sido associados à ocorrência de disfunções de movimento, ao desenvolvimento de patologias e à redução no desempenho em atividades como marcha, corrida e salto. Testes clínicos para investigar a rigidez dessa articulação podem ser úteis no processo de avaliação fisioterápica. OBJETIVOS: Investigar a validade concorrente e as confiabilidades intra e interexaminadores de medidas clínicas para avaliação da rigidez passiva do tornozelo durante o movimento de dorsiflexão. MÉTODOS: Quinze voluntários saudáveis foram submetidos a avaliações teste-reteste do tornozelo por dois examinadores. Duas medidas clínicas foram realizadas: "posição de primeira resistência detectável" e "mudança do torque passivo de resistência". Os resultados desses testes foram comparados à medida da rigidez passiva realizada com um dinamômetro isocinético, no qual a atividade eletromiográfica dos músculos foi monitorada para garantir que o teste fosse realizado passivamente (medida padrão-ouro). RESULTADOS:Os Coeficientes de Pearson variaram de r=-0,81 a -0,88 (p<0,001) para a correlação entre a medida da rigidez com o dinamômetro isocinético e os resultados da medida "posição de primeira resistência detectável". Para a medida "mudança do torque passivo de resistência", esses coeficientes variaram de r=0,72 a 0,83 (p<0,004). Os Coeficientes de Correlação Intraclasse (CCIs) obtidos para as confiabilidades intra e interexaminadores variaram de 0,75 a 0,98. CONCLUSÃO: Os testes propostos apresentaram validade e confiabilidades satisfatórias para serem utilizados na prática clínica.


Subject(s)
Female , Humans , Male , Young Adult , Ankle Joint/physiopathology , Muscle Strength Dynamometer , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL