1.
Cad. saúde pública ; 30(2): 403-414, 02/2014. tab, graf
Article in English | LILACS | ID: lil-703182

ABSTRACT

A cross-sectional study was conducted to determine the distribution of serum cadmium (Cd) levels in blood donors in Rio Branco, Acre State, Brazil. Blood samples were obtained from 922 volunteer blood donors from 18 to 65 years of age at the Hemoacre blood center in 2010-2011. Mean serum Cd was 0.37µg/L (95%CI: 0.33-0.41). Increased serum Cd was associated with lower schooling; individuals with less than five years of schooling showed a mean Cd of 0.61µg/L (95%CI: 0.34-0.89), compared to 0.34µg/L (95%CI: 0.28-0.40) among those with more than nine years of schooling. Mean serum Cd was three times higher among smokers. Smoking showed a positive association with Cd level, with an OR of 12.36 (95%CI: 7.70-19.84). Meanwhile, serum Cd was lower among individuals that regularly drank tea, as compared to non-tea drinkers. Serum Cd levels were mostly below the reference value (88.3% of participants). Mean serum Cd in the current study indicates that in general the population studied here is not exposed to worrisome Cd levels.


Objetivou-se, por meio de estudo transversal, determinar a distribuição dos níveis séricos de cádmio (Cd) em doadores de sangue em Rio Branco, Acre, Brasil. O sangue foi obtido de 922 doadores voluntários entre 18 e 65 anos no Hemoacre, entre 2010-2011. A média da concentração de Cd foi de 0,37µg/L (IC95%: 0,33-0,41). Houve tendência de aumento com a diminuição do nível de escolaridade; indivíduos com menos de cinco anos de estudo apresentaram média de 0,61µg/L (IC95%: 0,34-0,89), enquanto aqueles com mais de nove anos de estudo obtiveram média de 0,34µg/L (IC95%: 0,28-0,40). A média da concentração de Cd apresentou-se três vezes maior entre os fumantes. O tabagismo demonstrou associação positiva com OR 12,36 (IC95%: 7,70-19,84). Já a concentração de Cd entre os indivíduos com hábitos de tomar chás apresenta- se menor quando comparada àqueles que não utilizam. Os níveis séricos de Cd foram, em sua maioria, abaixo do valor de referência (88,3% dos participantes). As médias encontradas no presente estudo indicam que, no geral, a população estudada não está exposta a níveis preocupantes de exposição ao Cd.


El objetivo de utilizar un estudio transversal para determinar la distribución de los niveles séricos de Cd en los donantes de Río Branco no expuestos al metal. Se obtuvo sangre de 922 voluntarios de entre 18 y 65 años en Hemoacre entre 2010-2011. La concentración media de Cd fue 0,37µg/L (IC95%: 0,33-0,41). Hubo una tendencia de aumento según el nivel educativo: las personas con menos de cinco años de estudio tenían una media de 0,61µg/l (IC95%: 0,34-0,89), mientras que quienes contaban con más de nueve años de escolaridad poseían un promedio 0,34µg/L (IC95%: 0,28-0,40). La concentración promedio de Cd se presentó tres veces mayor entre los fumadores. El consumo de cigarrillos mostró una asociación positiva con OR 12,36 (IC95%: 7,70-19,84). Ya la concentración de Cd en las personas con hábitos de tomar té era más pequeña en comparación con aquellos que no lo toman. Los niveles séricos de Cd fueron en su mayoría por debajo del valor de referencia (88,3% de los participantes). Los medios encontrados en este estudio indican que, en general, la población no está expuesta a niveles preocupantes de Cd.


Subject(s)
Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Blood Donors , Cadmium/blood , Environmental Exposure/analysis , Brazil , Cross-Sectional Studies , Environmental Monitoring , Risk Factors , Socioeconomic Factors , Smoking/blood
2.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 43(4): 639-647, out.-dez. 2007. ilus, graf, tab
Article in English | LILACS | ID: lil-479334

ABSTRACT

We report the development and validation of a new sensitive, accurate and precise HPLC method with ultraviolet detection for the determination of indinavir sulfate (IND) in human plasma and its application to a bioequivalence study of a new generic formulation. The extraction of IND from plasma samples was achieved by using liquid-liquid extraction with a mean recovery of 73.9 percent. The lower limit of quantification was 0.05 µg/mL. Bioequivalence between the products was determined by calculating 90 percent confidence intervals (CI) for the ratio of Cmax, AUC0-t and AUC0-inf values for the test and reference products, within the 0.80-1.25 interval proposed by ANVISA and FDA. Therefore the medications are bioequivalent and inter-exchangeable.


Foi desenvolvido e validado um novo método, sensível, exato e preciso por Cromatografia a Líquido de Alta Eficiência com detecção em UV para a determinação do sulfato de indinavir (IND) em plasma humano. O fármaco foi extraído do plasma através de extração líquido-líquido obtendo recuperação média de 73.9 por cento, com limite inferior de quantificação de 0.05 µg/mL. O método foi aplicado em estudo de farmacocinética para verificar a bioequivalência entre um novo medicamento genérico e seu produto de referência. A bioequivalência entre os produtos foi determinada calculando-se um intervalo de confiança (IC) de 90 por cento para a razão das médias do produto teste e referência compreendidas entre o intervalo de 0.80-1.25 proposto pela ANVISA e O FDA. Os produtos estudados são bioequivalentes e, portanto, intercambiáveis.


Subject(s)
Indinavir/pharmacokinetics , Plasma/metabolism , Chromatography, Liquid/methods , Therapeutic Equivalency
SELECTION OF CITATIONS
SEARCH DETAIL