Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Journal of the Korean Radiological Society ; : 623-628, 1999.
Article in Korean | WPRIM | ID: wpr-186719

ABSTRACT

PURPOSE: To evaluate the MR findings of dural arteriovenous fistula(DAVF) in the cavernous sinus and to determine the most useful imaging method for the diagnosis of DAVF. MATERIALS AND METHODS: We evaluated the MR findings of 12 patients in whom DAVF was diagnosed in the cavernous sinus on the basis of angiographic findings. Axial T1- and T2-weighted, and axial and coronal Gd-enhanced T1-weighted images with 3-6mm slice thickness had been obtained, and the findings of DAVF on three pulse sequences were examined and compared. On the basis of the detection of DAVF on three pulse sequences, the MR findings were graded as excellent, fair or poor, and the location of DAVF in the cavernous sinus was analysed. We also classified DAVFs as group A or B on the basis of MR findings (group A: lesions in the cavernous sinus were as large as or larger than the cavernous internal carotid artery; group B: these were smaller than the cavernous internal carotid artery) and compared with cognard type on angiogram. RESULTS: Multiple tortuous signal voids were found in all DAVFs. The signal voids were located mainly in the middle and posterior one third of the cavernous sinus, as seen on axial images, and the middle and inferior one third, as seen on coronal images. Axial and coronal enhanced T1-weighted images showed an excellent grade in 11 of 12 cases and a fair grade in 1 of 12. Axial T2-weighted images showed an excellent grade in 6 of 12 cases and a fair grade in 4 of 12. T1-weighted images showed an excellent grade in 4 of 12 cases and a fair grade in 6 of 12. Six cases were group A, and 5 of the 6 were Cognard type IIa or IIb; The other 6 cases were group B, 5 of the 6 were Cognard type I. CONCLUSION: MR findings of multiple tortuous signal voids in the cavernous sinus, especially in the posterior or inferior portion, suggest DAVF, and enhanced T1-weighted imaging could be the most useful sequence for its diagnosis.


Subject(s)
Humans , Arteriovenous Fistula , Carotid Artery, Internal , Cavernous Sinus , Central Nervous System Vascular Malformations , Diagnosis
2.
Journal of the Korean Radiological Society ; : 699-704, 1999.
Article in Korean | WPRIM | ID: wpr-140307

ABSTRACT

PURPOSE: To determine the rate of successful biopsy and frequency of post-biopsy pneumothorax and hemorrhage using an 18-gauge cutting needle in CT-guided automated needle biopsies according to lesion size, and the distance between lesion and pleura. MATERIALS AND METHODS: Ninety-four patients with focal lung lesion who had undergone CT-guided automated needle biopsies using an 18-gauge cutting needle were retrospectively reviewed. We evaluated the relationship between successful biopsy rate and pneumothorax and hemorrhage according to lesion size and distance between lesion and pleura. For the purposes of this study, size and distance were grouped as follows : 3cm . RESULTS: Biopsy was successful in 78 of 94 patients(83%). When lesions were larger than 2cm in size the diagnostic rate increased (P=0.002), but the distance between lung lesion and pleura was not statistically related to successful biopsy (P>0.005). Where there were post-biopsy complications, the pneumothorax rate was higher in lesions less than 2 cm in size (P=0.041) and in those separated by more than 2 cm from the pleura (P= 0.006). Where separation was of this order, the hemorrhage rate was higher (P=0.021), but statistically, this was not affected by lesion size (P>0.05). CONCLUSION: When 18-gauge cutting needle is used in CT-guided automated needle biopsies of pulmonary lesions, the rate of successful biopsy is affected by lesion size ; the pneumothorax rate is also affected by lesion size, as well as by the distance between lesion and pleura; the hemorrhage rate is influenced only by the distance between lesion and pleura.


Subject(s)
Humans , Biopsy , Biopsy, Needle , Hemorrhage , Lung , Needles , Pleura , Pneumothorax , Retrospective Studies
3.
Journal of the Korean Radiological Society ; : 699-704, 1999.
Article in Korean | WPRIM | ID: wpr-140306

ABSTRACT

PURPOSE: To determine the rate of successful biopsy and frequency of post-biopsy pneumothorax and hemorrhage using an 18-gauge cutting needle in CT-guided automated needle biopsies according to lesion size, and the distance between lesion and pleura. MATERIALS AND METHODS: Ninety-four patients with focal lung lesion who had undergone CT-guided automated needle biopsies using an 18-gauge cutting needle were retrospectively reviewed. We evaluated the relationship between successful biopsy rate and pneumothorax and hemorrhage according to lesion size and distance between lesion and pleura. For the purposes of this study, size and distance were grouped as follows : 3cm . RESULTS: Biopsy was successful in 78 of 94 patients(83%). When lesions were larger than 2cm in size the diagnostic rate increased (P=0.002), but the distance between lung lesion and pleura was not statistically related to successful biopsy (P>0.005). Where there were post-biopsy complications, the pneumothorax rate was higher in lesions less than 2 cm in size (P=0.041) and in those separated by more than 2 cm from the pleura (P= 0.006). Where separation was of this order, the hemorrhage rate was higher (P=0.021), but statistically, this was not affected by lesion size (P>0.05). CONCLUSION: When 18-gauge cutting needle is used in CT-guided automated needle biopsies of pulmonary lesions, the rate of successful biopsy is affected by lesion size ; the pneumothorax rate is also affected by lesion size, as well as by the distance between lesion and pleura; the hemorrhage rate is influenced only by the distance between lesion and pleura.


Subject(s)
Humans , Biopsy , Biopsy, Needle , Hemorrhage , Lung , Needles , Pleura , Pneumothorax , Retrospective Studies
4.
Journal of the Korean Academy of Family Medicine ; : 744-752, 1992.
Article in Korean | WPRIM | ID: wpr-189400

ABSTRACT

No abstract available.


Subject(s)
Child , Humans
SELECTION OF CITATIONS
SEARCH DETAIL