1.
The Medical Journal of Malaysia ; : 325-333, 2015.
Article in English | WPRIM | ID: wpr-630658

ABSTRACT

Objective: The aim of this study was to compare the use of semi-automated (Medax Velox 2; Poggio Rusco, Italy) and automated (Bard Magnum Biopsy Instrument; Covington, GA, USA) core biopsy needles, for ultrasound guided breast biopsy. Materials and Methods: A 14G semi-automatic spring loaded core biopsy needle with a 22-mm-throw (Medax Velox 2; Poggio Rusco, Italy) and 14-gauge automated needle device with a 22-mm-throw biopsy gun (Bard-Magnum Biopsy Instrument, Covington, GA, USA) were used for breast biopsies under ultrasound guidance on alternate months during the study period between July 2009 and May 2011. One hundred and sixty lesions were biopsied and specimens were sent for histological evaluation. Results: The automated needle obtained a higher number of histology reports at 84% (67/80) as compared with the semiautomated needle at 60% (48/80) (Fisher exact test, p value=0.023). Inadequate samples with the automated needle were much less at 9% (7/60) than with the semiautomated needle at 23% (18/60) (Fisher exact test, p value=0.028). The semi-automated needle showed slightly less fragmented samples. However, the number of fragmented samples with definitive diagnosis was slightly higher with the automated compared with the semiautomated needle, at 16% (13/80) and 13% (10/80) respectively. Compared with histology of 29 lesions that were excised, the semi-automated needle had higher sensitivity (100%) but lower specificity (75%) and accuracy (90%) compared with the automated needle (88% sensitivity, 100% specificity, 95% accuracy). Conclusion: Definitive diagnosis from the study samples slightly favours the use of automated core biopsy needle as compared to semi-automated core biopsy needle.

2.
The Medical Journal of Malaysia ; : 158-161, 2015.
Article in English | WPRIM | ID: wpr-630528

ABSTRACT

SUMMARY Aim: This study was conducted to measure the cross sectional area (CSA) of the ulnar nerve (UN) in the cubital tunnel and to evaluate the role of high-resolution ultrasonography in the diagnosis of ulnar nerve neuropathy (UNN). Materials and Methods This was a cross sectional study with 64 arms from 32 patients (34 neuropathic, 30 nonneuropathic). Diagnosis was confirmed by nerve conduction study and electromyography. The ulnar nerves were evaluated with 15MHz small footprint linear array transducer. The ulnar nerve CSA was measured at three levels with arm extended: at medial epicondyle (ME), 5cm proximal and 5cm distal to ME. Results from the neuropathic and nonneuropathic arms were compared. Independent T-tests and Pearson correlation tests were used. P value of less than 0.05 was considered significant. Results: Mean CSA values for the UN at levels 5cm proximal to ME, ME and 5cm distal to ME were 0.055, 0.109, 0.045 cm2 respectively in the neuropathic group and 0.049, 0.075, 0.042 cm2 respectively in the non-neuropathic group. The CSA of the UN at the ME level was significantly larger in the neuropathic group, with p value of 0.005. However, there was no statistical difference between the groups at 5cm proximal and distal to the ME, with p values of 0.10 and 0.35 respectively. Conclusion: There is significant difference in CSA values of the UN at ME between the neuropathic and non-neuropathic groups with mean CSA value above the predetermined 0.10cm2 cut-off point. High-resolution ultrasonography is therefore useful to diagnose and follow up cases of elbow UNN.


Subject(s)
Ulnar Nerve
3.
Malaysian Journal of Medical Sciences ; : 76-80, 2015.
Article in English | WPRIM | ID: wpr-628949

ABSTRACT

Overexpression of beta-human chorionic gonadotropin (β-hCG) is frequently associated with germ cell tumours, especially choriocarcinoma. Ectopic secretion of β-hCG by non-small cell lung cancer is exceptional. We present an exceedingly rare case of pulmonary adenocarcinoma that secretes β-hCG. Our patient is a 62-year-old postmenopausal woman, a nonsmoker, who presented with a six-month history of progressive dyspnoea, associated with decreased appetite and significant weight loss. Her serum β-hCG was very high (11211.9 mIU/ml), which prompted investigations to exclude germ cell tumour. Radiological imaging revealed a 10-cm right lung mass with adrenal metastasis. No other focal lesions were detected. Microscopy of the lung biopsy specimen showed replacement of normal lung tissue by sheets of malignant cells, forming vague glands in some areas. Immunohistochemically, the malignant cells showed focal immunopositivity for thyroid transcription factor 1 (TTF-1), napsin A, cytokeratin 7 (CK7) and β-hCG. A diagnosis of β-hCG-secreting pulmonary poorly differentiated adenocarcinoma was rendered. Serum β-hCG level decreased significantly to 168.6 mIU/ml after the first cycle of chemotherapy. In conclusion, β-hCG expression in lung cancer should be recognised to facilitate prompt diagnosis and initiation of appropriate intervention.

4.
Malaysian Journal of Medical Sciences ; : 83-87, 2013.
Article in English | WPRIM | ID: wpr-628191

ABSTRACT

Lymphocytic mastitis, or diabetic mastopathy, is an unusual finding in early-onset and long-standing diabetes. It can presents as a non-tender or tender palpable breast mass. Mammogram and ultrasound frequently demonstrate findings suspicious of malignancy, thus biopsy and histological confirmation is usually required. We reviewed two cases of lymphocytic mastitis with characteristics findings on mammogram, ultrasound, and histopathology. Diagnoses were confirmed with excision biopsy.


Subject(s)
Breast Neoplasms , Diabetes Mellitus
5.
Malaysian Journal of Health Sciences ; : 65-72, 2009.
Article in English | WPRIM | ID: wpr-625897

ABSTRACT

Digital mammography has been progressively introduced in screening centers and the concern is to achieve an image of diagnostic value which would be able to detect early changes in the breast tissue. The aim of this study was to evaluate the image quality of mammograms using quantitative and qualitative methods of two FFDM systems with variations in breast thickness and anode/filter combination. This study was done from January to April 2008 with two FFDM systems; Siemens Mammomat NovationDR at Diagnostic Imaging Department, Hospital Kuala Lumpur and Hologic Lorad Selenia at Breast Clinic, National Cancer Society. A CIRS012A tissue equivalent breast phantom (4, 5 and 6 cm) thickness was used to obtain images in the craniocaudal plane with 26-32 kVp and a combination of molybdenum/molybdenum (Mo/Mo) and molybdenum/rhodium (Mo/Rh) anode/filter. For the qualitative evaluation, two independent radiologist with a minimum of five years experience was used to score the images. Wilcoxon Sign Rank Test showed that there are no significant differences (p > 0.05) in image quality between both the FFDM systems. Kappa analysis had a poor agreement between the scores given by the two radiologists. The quantitative analysis using Mann-Whitney test showed that there are significant differences (p < 0.05) between the SNR values of both FFDM systems. Although the qualitative evaluation was similar, the study showed that Lorad Selenia had a significantly superior SNR value, hence would be a better tool to detect early changes in the breast tissue. This study also demonstrated that a lower kVp is more suitable with molybdenum filter and as the breast thickness is increased rhodium filter with higher kVp displayed better quality images.