1.
Clinics in Orthopedic Surgery ; : 436-443, 2023.
Article in English | WPRIM | ID: wpr-976755

ABSTRACT

Background@#Spinopelvic fixation (SPF) has been a challenge for surgeons despite the advancements in instruments and surgical techniques. C-arm fluoroscopy-guided SPF is a widely used safe technique that utilizes the tear drop view. The tear drop view is an image of the corridor from the posterior superior iliac spine to the anterior inferior iliac spine (AIIS) of the pelvis. This study aimed to define the safe optimal tear drop view using three-dimensional reconstruction of computed tomography images. @*Methods@#Three-dimensional reconstructions of the pelvises of 20 individuals were carried out. By rotating the reconstructed model, we simulated SPF with a cylinder representing imaginary screw. The safe optimal tear drop view was defined as the one embracing a corridor with the largest diameter with the inferior tear drop line not below the acetabular line and the lateral tear drop line medial to the AIIS. The distance between the lateral border of the tear drop and AIIS was defined as tear drop index (TDI) to estimate the degree of rotation on the plane image. Tear drop ratio (TDR), the ratio of the distance between the tear drop center and the AIIS to TDI, was also devised for more intuitive application of our simulation in a real operation. @*Results@#All the maximum diameters and lengths were greater than 9 mm and 80 mm, respectively, which are the values of generally used screws for SPF at a TDI of 5 mm and 10 mm in both sexes. The TDRs were 3.40 ± 0.41 and 3.35 ± 0.26 in men and women, respectively, at a TDI of 5 mm. The TDRs were 2.26 ± 0.17 and 2.14 ± 0.12 in men and women, respectively, at a TDI of 10 mm. @*Conclusions@#The safe optimal tear drop view can be obtained with a TDR of 2.5 to 3 by rounding off the measured values for intuitive application in the actual surgical field.

2.
The Journal of Korean Knee Society ; : 155-161, 2014.
Article in English | WPRIM | ID: wpr-759142

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the biomechanical properties of a new anatomical locking metal block plate by comparing the initial biomechanical stability of three different fixation constructs for open wedge high tibial osteotomy (HTO). MATERIALS AND METHODS: Sawbones composite tibiae were used to make a 10-mm opening osteotomy model with uniplane technique. The osteotomy was secured with three different types of plates: Group I, new osteotomy plate without a metal block (n=5); Group II, new osteotomy plate with a 10-mm metal block (n=5); and Group III, two short metal block plates (n=5). Single load to failure test and staircase load-controlled cyclical failure test were performed. In the single load to failure test, the yield load, maximum failure load, and the displacement of the osteotomy gap were measured. In the staircase cyclical load to failure test, the total number of cycles to failure was recorded. Failure modes were observed during both single and cyclic load tests. RESULTS: Group II showed the highest yield and ultimate loads (1829+/-319 N, 3493+/-1250 N) compared to Group I (1512+/-157 N, 2422+/-769 N) and Group III (1369+/-378 N, 2157+/-210 N, p<0.05). The displacement of the opening gap in Group II (0.34+/-0.35 mm) was significantly lesser than the other groups (p<0.05). In the staircase cyclical load to failure test, the total number of cycles to failure was 12,860 at 950 N in Group III, 20,280 at 1,140 N in Group I, and 42,816 at 1,330 N in Group II (p<0.05). All the specimens showed complete fracture of the intact lateral sawbones area and slight displacement of the distal fragment of the specimens in the single load to test. None of the specimens showed deformed or broken screws and plates during the single load to test. During the fatigue test with staircase cyclic loading, no fracture of the lateral sawbones area was observed. CONCLUSIONS: This study demonstrated that the new anatomical locking metal block plate could provide sufficient primary stability for open wedge HTO. The addition of a metal block to this new plate can increase the stability of the osteotomy compared to the one without a metal block.


Subject(s)
Fatigue , Knee , Osteotomy , Tibia
SELECTION OF CITATIONS
SEARCH DETAIL