Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
The Journal of Advanced Prosthodontics ; : 162-172, 2022.
Article in English | WPRIM | ID: wpr-939038

ABSTRACT

PURPOSE@#The present study aims to analyze the effect of abutment neck taper and types of cement on the amount of undetected remnant cement of cement-retained implant prostheses. @*MATERIALS AND METHODS@#Three neck taper angles (53°, 65°, 77°) and three types of cement (RMGI: resin-modified glass ionomer, ZPC: zinc phosphate cement, ZOE: zinc oxide eugenol cement) were used. For each group, the surface percentage was measured using digital image and graphic editing software. The weight of before and after removing remnant cement from the abutment-crown assembly was measured using an electronic scale. Two-way ANOVA and Duncan & Scheffe’s test were used to compare the calculated surface percentage and weight of remnant cement (α = .05). @*RESULTS@#There were significant differences in remnant cement surface percentage and weight according to neck taper angles (P .05). The wide abutment with a small neck taper angle showed the most significant amount of remnant cement. And the types of luting cement did not influence the amount of residual cement. @*CONCLUSION@#To remove excess cement better, the emergence profile of the crown should be straight to the neck taper of the abutment in cement-retained implant restoration.

2.
Journal of Dental Rehabilitation and Applied Science ; : 314-321, 2016.
Article in Korean | WPRIM | ID: wpr-152731

ABSTRACT

Conventional removable partial dentures (RPDs) with distal extensions are associated with some problems, including lack of stability that calls for frequent relining, and cantilever actions of claps that can produce excessive loading to abutment teeth, and the need for unesthetic retentive arm clasps. Therefore, IARPDs (Implant-assisted RPD) that use implants to support or retain RPDs has been reported to improve stability, esthetics and masticatory performance of RPDs. Also, an IARPD that has zirconia occlusal table can prevent the incongruity of occlusal plane and the extrusion of antagonistic tooth. In this case of partially edentulous patient with crossed occlusion, each edentulous area was restored with implant fixed prosthesis and implant retained partial denture to suit each situation. Through the procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.


Subject(s)
Humans , Arm , Dental Occlusion , Denture, Partial , Denture, Partial, Removable , Esthetics , Mouth Rehabilitation , Mouth , Prostheses and Implants , Tooth
3.
Journal of Dental Rehabilitation and Applied Science ; : 214-223, 2016.
Article in Korean | WPRIM | ID: wpr-217994

ABSTRACT

Implant-assisted removable partial denture (Implant-assisted RPD, IARPD), posterior edentulous extension areas of which obtains additional support and retention from implants, is attracting increasing interest. This case report presents a successful treatment on a partially edentulous patient with a severely canted occlusal plane resulted from a long-term use of posterior extended RPD. The full mouth was rehabilitated through a fixed prosthesis on maxilla and IARPD with zirconia occlusal surface on mandible, which allowed to achieve an esthetic occlusal plane with long-term stability and, ultimately, functionally satisfying outcome.


Subject(s)
Humans , Dental Occlusion , Denture, Partial, Removable , Mandible , Maxilla , Mouth Rehabilitation , Mouth , Prostheses and Implants
SELECTION OF CITATIONS
SEARCH DETAIL