Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
RGO (Porto Alegre) ; 63(4): 397-404, Oct.-Dec. 2015. tab
Article in English | LILACS-Express | LILACS | ID: lil-770574

ABSTRACT

Objective: To evaluate the effect of aging in a hard denture reline (New Truliner) and an acrylic resin (Classic) after chemical and mechanical polishing. Methods: Eighty specimens were made, divided randomly between 8 groups: G1.Acrylic Resin Classic (RAC)/Mechanical Polishing (PM); G2.RAC/PM + thermocycling (TR); G3) RAC/Chemical Polishing (PQ); G4.RAC/PQ + TR; G5.New Truliner (NT)/PM; G6.NT/PM + TR; G7. NT/PQ; G8.NT/PQ + TR. The surface hardness was measured before and after polishing, and after TR. The impact resistance tests were measured after all applied treatments. The data were submitted to ANOVA and Tukey test (a=5%). Results: Regardless of the polishing, it was noted that RAC presented significantly higher surface hardness than NT; PM had higher hardness in both materials compared with PQ; on both polishing, the impact resistance of the RAC was higher than NT. Independently of TR test, the impact resistance of the materials that received PQ was higher than received PM. The PQ caused greater changes in properties than the PM. Conclusion: Aging and chemical and mechanical polishing influenced the physical and mechanical properties of hard denture reline and acrylic resin.


Objetivo: Avaliar o efeito da termociclagem em reembasador rígido para próteses totais (New Truliner) e resina acrílica (Clássico) após polimento químico e mecânico. Métodos: Foram confeccionados 80 corpos de prova, divididos de forma randomizada entre 8 grupos: G1. Resina Acrílica Clássico (RAC)/Polimento mecânico (PM); G2. RAC/PM + termociclagem (TR); G3.RAC/Polimento químico (PQ); G4.RAC/PQ + TR; G5.New Truliner (NT)/PM; G6.NT/PM + TR; G7. NT/PQ; G8. NT/PQ + TR. A dureza superficial foi mensurada antes e após os polimentos, e após a TR. Os ensaios de resistência ao impacto foram mensurados após todos os tratamentos. Os dados foram submetidos à análise de variância e Tukey (a=0,05). Resultados: Independente do polimento verificou-se que RAC apresentou resultados de dureza superficial significativamente mais altos que NT; PM gerou superfícies mais duras em ambos os materiais quando comparado ao PQ; em ambos os polimentos, os valores de resistência ao impacto da RAC foram maiores que os do NT. Independentemente da realização da TR, a resistência ao impacto dos materiais que receberam PQ foi maior que a dos que receberam PM. PQ causou maior alteração nas propriedades do que PM. Conclusão: A termociclagem e os polimentos químico e mecânico influenciam as propriedades físicas e mecânicas do reembasador rígido e da resina acrílica.

2.
Full dent. sci ; 5(20): 590-594, jul.-set. 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-737448

ABSTRACT

O sucesso da reabilitação protética, estética e funcional requer, na maioria dos casos, um plano de tratamento transdisciplinar. Este trabalho tem como objetivo apresentar um caso de reabilitação bucal com a confecção de prótese total imediata (PTI) na arcada superior e prótese parcial removível provisória na arcada inferior. Os resultados demonstraram que o tratamento reabilitador com PTI foi resolutivo para o caso clínico, restabelecendo estética e função sem submeter a paciente a um período de edentulismo.


In most cases the success of prosthetic, esthetic and functional rehabilitation requires a multidisciplinary treatment plan. This work aims to present an oral rehabilitation case with immediate full denture (IFD) and lower provisional removable partial denture. The results showed that the rehabilitation treatment with IFD was the solution for the clinical case, restoring aesthetics and function without submitting the patient to an edentulous period.


Subject(s)
Humans , Female , Adult , Esthetics, Dental/psychology , Mouth Rehabilitation , Denture, Partial, Removable , Denture, Complete, Immediate , Models, Anatomic , Radiography, Panoramic/instrumentation
3.
RFO UPF ; 18(2): 160-164, Mai.-Ago. 2013. tab
Article in Portuguese | LILACS | ID: lil-720735

ABSTRACT

Diante da importância de oferecer um tratamento reabilitador adequado às condições dos pacientes atendidos em uma policlínica odontológica, busca-se saber quais as suas opiniões quanto à satisfação da instalação e utilização de próteses removíveis confeccionadas por estudantes de graduação em Odontologia. Objetivo: este estudo tem como objetivo a avaliação do grau de satisfação e qualidade de vida dos pacientes edentados totais e parciais reabilitados por estudantes de graduação. Materiais e método: trinta e dois pacientes foram chamados dois meses após a conclusão do tratamento reabilitador protético para consulta de proservação das próteses. Neste momento, os pacientes foram avaliados por meio do questionário OHIP-EDENT e por meio da escala visual analógica (EVA) para avaliar os critérios de qualidade de vida, estética, fonética, função mastigatória, estabilidade, conforto, alteração do paladar e dor referentes à prótese instalada. Os resultados foram submetidos ao teste t com nível de significância de 5%. Resultados: os pacientes reabilitados com prótese total apresentaram maior impacto na qualidade de vida (p = 0,01), relataram melhor estabilidade (p = 0,01) e função mastigatória (p = 0,01) em comparação aos reabilitados com próteses parciais. Não houve diferença nos critérios conforto, estética, fonética, alteração de paladar e dor (p > 0,05). Conclusões: o tipo de prótese pode influenciar no prognóstico da reabilitação. Além disso, pacientes reabilitados com próteses totais relatam maior percepção de melhora na qualidade de vida após a reabilitação.


Given the importance of offering proper rehabilitation for patients assisted in a dental polyclinic we have sought their opinion regarding installation and use of removable dental prosthesis manufactured by Dentistry students. Objective: this study aimed to assess the satisfaction level and quality of life of partially or totally edentulous patients rehabilitated by graduate students. Materials and method: thirty-two patients were called two months after the completion of the rehabilitating prosthetic treatment for an appointment of prosthesis proservation. At this time the patients were assessed through the OHIP-EDENT questionnaire and visual analogue scale (VAS) to assess criteria for quality of life, esthetics, phonetics, masticatory function, stability, comfort, palate alteration, and pain associated with the prosthesis installed. The results were submitted to t test with 5% significance level. Results: the patients rehabilitated with complete dentures presented higher impact on quality of life (p = 0.01), and reported better stability (p = 0.01) and masticatory function (p = 0.01) than patients rehabilitated with partial dentures. There was no difference for criteria of comfort, esthetics, phonetics, palate alteration, and pain (p > 0.05). Conclusions: the type of prosthesis may influence the rehabilitation prognosis. Moreover, patients rehabilitated with complete dentures reported more perception of improvement in quality of life after rehabilitation.

4.
Perionews ; 6(4): 417-424, jul.-ago. 2012. ilus
Article in Portuguese | LILACS, BBO | ID: lil-677186

ABSTRACT

O alto número de reabilitações orais com implantes, associadas à ausênciade uma correta terapia de manutenção, tem contribuído para o aparecimentode diversos casos de peri-implantite. Juntamente com este fato, odiagnóstico das doenças peri-implantares parece ser dificultado pelo desconhecimento,ou medo, dos cirurgiões-dentistas no exame das estruturasperi-implantares. O objetivo deste relato de caso clínico foi apresentaruma situação em que diagnóstico e tratamento da peri-implantite permitirama continuação e o sucesso da reabilitação oral com implantes. Dentrodas limitações do caso clínico apresentado concluiu-se que uma vez diagnosticadaa peri-implantite, a aplicação não cirúrgica de iodo povidine 10%,associado à abordagem cirúrgica, para a descontaminação da superfíciedos implantes e correção tecidual peri-implantar, por meio de enxerto detecido conjuntivo, e uma rigorosa terapia de suporte periodontal tornaramo resultado clínico satisfatório após 18 meses de acompanhamento, em setratando de estabilização do processo patológico.


Subject(s)
Humans , Male , Adult , Decontamination , Dental Implants , Maintenance , Peri-Implantitis , Periodontal Diseases
5.
Braz. oral res ; 25(2): 103-108, Mar.-Apr. 2011. ilus, tab
Article in English | LILACS | ID: lil-583858

ABSTRACT

Widely used in dentistry, Ti-6Al-4V alloy is difficult to cast and solder, as it frequently exhibits pores inside the structure. This study was conducted to evaluate the effect of joint openings and diameters of laser-welded joints executed in Ti-6Al-4V structures on the presence of pores as checked by radiographic procedures. Sixty dumbbell rods with central diameters of 1.5, 2.0 and 3.5 mm were created from Ti-6Al-4V-wrought bars. Specimens were sectioned and welded using two joint openings (0.0 and 0.6 mm). The combination of variables created six groups (n = 10). Laser welding was executed using 360V/8ms (1.5 and 2.0 mm) and 380V/9ms (3.5 mm), with the focus and frequency set to zero. The joints were finished, polished and submitted to radiographic examination. The radiographs were visually examined for the presence of pores in the joints, qualitatively. The percentage of radiographic presence of pores was calculated without counting pores per joint. Data were analyzed using a chi-square test (α = 0.05). For the 1.5-mm specimens, the incidence of pore presence was significantly higher (p = 0.0001) when using 0.6-mm joint openings (40 percent) compared to 0.0-mm openings (0 percent). For the 2.0-mm specimens, there was no significant difference between groups (p = 0.2008). However, for the 3.5-mm specimens, the incidence of pore presence was lower (p = 0.0061) for 0.6-mm openings (50 percent) compared to 0.0-mm openings (70 percent). Therefore, laser welding of Ti-6Al-4V structures with thin diameters provides the best condition for the juxtaposition of the parts.


Subject(s)
Dental Soldering/methods , Porosity , Radiography, Dental , Titanium/chemistry , Chi-Square Distribution , Dental Casting Technique , Dental Materials/chemistry , Lasers , Materials Testing , Surface Properties
6.
Braz. dent. sci ; 14(3/4): 12-17, 2011. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-727412

ABSTRACT

Esse estudo foi conduzido para avaliar a possibilidade de visualização de porosidade interna em radiografias periapicais de uniões soldadas a laser, confeccionadas em estruturas de titânio (Ti) comercialmente puro (cp), em diferentes situações de soldagem. Foram confeccionados halteres em resina acrílica, com diâmetros centrais de 1,5; 2,0; e 3,5 mm, por meio de uma matriz metálica bipartida. Os halteres em resina foram fundidos em Ti cp e após acabamento e polimento, seccionados em duas partes iguais. As partes foram alinhadas e fixadas de tal forma que as distâncias entre elas fossem 0,0 e 0,6 mm. A combinação entre as variáveis (distância de soldagem e diâmetro dos halteres) gerou seis grupos (n=10). A soldagem a laser foi realizada com as seguintes especificações: 360V/8ms (1,5 e 2,0 mm) e 380V/9ms (3,5 mm), com foco e freqüência regulados em zero, em um aparelho de soldagem a laser Desktop-F. As uniões obtidas receberam acabamento, polimento e foram submetidas à análise radiográfica com exposição à radiação (90 KV, 15 mA, 0,6 seg e 10 a 13 mm de distância) utilizando filme periapical. As radiografias foram analisadas visualmente quanto à presença de porosidade nas uniões soldadas, e os dados obtidos, submetidos ao teste Qui-Quadrado (5%). Com isso, verificou-se ser possível visualizar porosidade interna nessas uniões. Em corpos de prova de menores diâmetros, 1,5 e 2,0 mm, a incidência é maior quando a distância é 0,6 mm. Entretanto, em corpos de prova de 3,5 mm, a incidência é alta para ambas as uniões, não diferindo estatisticamente entre si.


This study was conducted to evaluate the possibility of porosity inspection in laser-weld joints executed in cp titanium structures, by radiographic analyses. Sixty acrylic dumbbells rods with 1.5, 2.0 and 3.5 mm central diameter were prepared by lost-wax casting procedure. The casted specimens were finished, polished and sectioned in two halves. The parts were lined up in a metal matrix and fixed according two welding distances (0.0 and 0.6 mm). The combination between diameter and welding distance created a total of six groups (n = 10). The laser welding was executed as follows: 360V/8ms (1.5 and 2.0 mm) and 380V/9ms (3.5 mm) with focus and frequency regulated to zero. The achieved joints were finished, polished and submitted to radiographic examination (90 KV, 15 mA, 0.6 second and 10 to 13 mm of distance) with periapical film. The radiographies were visually analyzed for the presence of internal porosity in the joints. The data was submitted to Chi-Square test (5%). Herewith, it was possible to visualize internal porosity in the analyzed joints. In thin specimens, 1.5 and 2.0 mm, the porosity incidence was higher when the joint distance was 0.6 mm. However, in 3.5 mm specimens, this incidence was high for both joint openings.


Subject(s)
Dental Casting Technique , Dental Soldering , Radiography, Dental , Titanium
7.
Braz. j. oral sci ; 9(3): 376-379, July-Sept. 2010. ilus, tab
Article in English | LILACS, BBO | ID: lil-578059

ABSTRACT

Aim: Success of implant-supported prostheses is related to the frameworks’ passive fit, henceinaccuracies can generate stress, leading to bone resorption and rehabilitation failure. This study evaluated misfit levels of implant-supported frameworks after different coverage treatments.Methods: Twenty commercially pure titanium (CP Ti) frameworks were manufactured with 5Branemark type multi-unit abutments. Frameworks were distributed in two groups as follows: G1- porcelain application (n=10); G2 - porcelain firing cycle simulation (n=10). Using a traveling microscope, marginal misfit was measured before and after undertaking the techniques, following the single-screw test protocol. All data were submitted to ANOVA and Tukey’s test (p<0.05).Results: Initial marginal misfit values were not significantly different, but both groups presented significantly higher misfit values after treatment: G1: 233.99 ìm (p=0.0003); G2: 119.75 ìm(p<0.0001). In addition, G1 presented higher misfit than G2 (p<0.0001). Conclusions: Porcelain application promoted significantly higher increase of misfit, which indicates that such procedure should be considered on misfit analysis of implant-supported prostheses.


Subject(s)
Dental Marginal Adaptation , Dental Porcelain/chemistry , Dental Prosthesis, Implant-Supported/instrumentation , Metal Ceramic Alloys/chemistry , Titanium/chemistry , Analysis of Variance , Dental Casting Technique , Hot Temperature , Materials Testing , Prosthesis Design
8.
RFO UPF ; 15(2): [197-202], maio-ago. 2010. tab
Article in Portuguese | LILACS, BBO | ID: biblio-874364

ABSTRACT

Objetivo: As propriedades dos materiais resilientes são alteradas quando o produto está em meio aquoso, sejaem saliva, seja em água destilada ou agentes químicos de limpeza. O processo de lixiviação sofrido pelo material resulta em endurecimento progressivo, distorção e alteração de rugosidade, apresentando longevidadeinferior à da prótese. Assim, este estudo foi realizado para avaliar e comparar a sorção, solubilidade e rugosidade superficial de um material reembasadorresiliente a base de resina acrílica (Eversoft®) em sua composição química original e com adição de citrato(experimental). Métodos: Foram confeccionados vinte corpos-de-prova de cada material com dimensões de45 mm de diâmetro X 1 mm de espessura, distribuídos em quatro grupos (n = 10). G1): Eversoft® com selante; G2): Eversoft® sem selante; G3): Experimental sem selante; e G4): Experimental com selante. Os corpos-deprova foram armazenados em água destilada em estufa à temperatura de 37 C e submetidos à termociclagem,sendo avaliados em quatro tempos: T0 = 0 (Controle), T1 = 1000 ciclos, T2 = 2000 ciclos, T3 = 3000 ciclos. Resultados: A adição de citrato na fórmula do Eversoft influenciou na rugosidade superficial, sorção e solubilidade do material; entretanto, mediante a aplicação de selante houve redução da rugosidade superficial e sorção do Eversoft®, não havendo diferença entre os grupos. Os valores de solubilidade do Eversoft® com aplicação de selante foram significativamente inferiores aosdo citrato. Conclusão: O Eversoft®, quando manipulado de acordo com as indicações do fabricante, ou seja, utilizando o selante, apresentou propriedades semelhantes às do Grupo Experimental. A adição de citrato nãosubstituiu o uso de selante


Subject(s)
Dental Prosthesis , Denture Liners , Solubility
9.
Rev. odontol. Univ. Cid. Sao Paulo ; 21(3)set.-dez. 2009. tab
Article in Portuguese | LILACS-Express | LILACS | ID: lil-553623

ABSTRACT

Este artigo tem por objetivo discutir a contribuição da nutrição na qualidade vida dos indivíduos idosos e de que forma ela pode influenciar para uma velhice mais saudável. Serão abordados os aspectos bioquímicos e fisiológicos do envelhecimento, os aspectos relacionados à saúde bucal e às necessidades nutricionais dos idosos, assim como serão evidenciadas as alterações fisiológicas que direta ou indiretamente afetam a sua alimentação.


The main of this article is to discuss the influence of nutrition in the orderly?s quality of life and whether it can implicate in oral health or to contribute for a healthier old age. Considerations on biochemical and physiologic aspects of the aging will be considered, associated with the senior?s nutritional needs, as well as it will be evidenced the physiologic changes that directly or indirectly affect elder food consumption.

10.
RPG rev. pos-grad ; 14(4): 321-326, out.-dez. 2007. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-529483

ABSTRACT

Esse trabalho avaliou os efeitos da pós-polimerização sobre as propriedades de resistência à tração de uma resina acrílica para base de prótese (QC-20) unida a reembasadores rígidos (New Truliner e Kooliner). Os materias utilizados foram proporcionados e manipulados, segundo as recomendações dos fabricantes. Foram confeccionados 40 amostras, separadas em quatro grupos (n = 10): G1: amostras reembasadas com Kooliner, sem o efeito da pós-polimerização (PP); G2: amostras reembasadas com New Truliner, sem PP; G3: amostras reembasadas com Kooliner, com PP, utilizando microondas com potência de 650W/5 min e G4: amostras reembasadas com New Truliner, com PP. As amostras foram confeccionadas utilizando matrizes metálicas incluídas em mufla, cujo molde impresso no silicone de condensação foi preenchido com resina acrílica. Após polimerizadas, as amostras em resina (40x10x10 mm), foram unidas duas a duas em seu eixo longitudinal pelo reembasador rígido (3 mm), e armazenadas em água destilada à + - 37°C durante uma semana. O ensaio de resistência à tração foi realizado em máquina universal EMIC DL-500 MF com velocidade de 5 mm/min. Os resultados obtidos foram submetidos a ANOVA e teste de Tukey (5%). A pós-polimerização não influenciou significativamente a resistência à tração de nenhum dos dois materiais ensaiados. O material Krooline apresentou valores significativamente maiores de resistência à tração tanto com PP quanto sem, quando comparado ao New Truliner.


Subject(s)
Acrylic Resins , Denture Liners , Tensile Strength , Analysis of Variance , Denture Bases , Dental Materials/analysis
SELECTION OF CITATIONS
SEARCH DETAIL