Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Japanese Journal of Cardiovascular Surgery ; : 56-61, 2024.
Article in Japanese | WPRIM | ID: wpr-1040094

ABSTRACT

Background: Unstable sternal fixation following sternotomy is one of the risk factors that affects postoperative outcomes in cardio-thoracic surgery and is associated with increased risk of infection, bleeding and delayed rehabilitation due to pain associated with sternal movement. Sternal plate systems, which help stabilize fixation, has been limited in use due to patients' comorbidities, such as diabetes mellitus (DM) and obesity. The conventional wire sternal-fixation procedure, which depend on years of physician' experience, raise concerns such as unstable sternal fixation due to uncompleted wire twisting. Therefore, a novel sternal-fixation procedure using both titanium cable and a PLA mesh plate was investigated as a potential improvement for sternal closure. We compared the ability of this new sternum fixation procedure (group N) against the conventional sternal fixation procedure using only a wire (group O) to achieve more stable postoperative sternal fixation. Methods and Results: Among adult open-heart surgeries performed between August 2020 and April 2023, 155 patients who underwent postoperative CT were included, with group N being the combined group and group O being the group using conventional metal wires: group N (86 patients: M 65, F 21) and group O (69 patients: M 50, F 19). Preoperative factors included age at surgery (group N: group O)=68.4±10.6 : 69.6±11.5 years (p=0.25)), BMI (group N: group O=23.0±3.7 : 24.1±7.7 (p=0.16)) and HbA1c (group N: group O=6.3±1.1 : 8.0±10.3% (p=0.10), and no factors were significantly different between the two groups. The CT analysis at the point of hospital discharge after surgery measured postoperative sternal deviation in the third rib position. Transverse displacement was significantly reduced (group N: group O=0.22±0.73: 0.83±1.08 mm (p=0.005)), and longitudinal displacement also showed an improvement but the difference was not statistically significant (group N: group O=0.53±0.86: 0.72±1.14 mm (p=0.13). Conclusion: A novel sternum closing technique using a tension-anchored titanium cable and a PLA mesh plate demonstrated improved postoperative sternal fixation in a controlled study with 155 patients. This new procedure also enables standardized stable sternal closure with a constant force without relying on conventional empirical sensation and without suppressing sternal cutting, thus contributing to the improvement of postoperative quality of life and prevention of complications.

2.
International Journal of Mycobacteriology. 2016; 5 (2): 170-176
in English | IMEMR | ID: emr-180451

ABSTRACT

Objective/background: the prevalence of pulmonary nontuberculous mycobacterial [pNTM] disease, including Mycobacterium avium complex [MAC], varies widely according to geographic region. However, the factors that influence regional variations in pNTM disease prevalence remain unknown. This study was undertaken to examine whether environmental or occupational factors or host traits could influence regional variations in pNTM disease prevalence


Methods: we collected laboratory data on pulmonary tuberculosis [pTB] and pNTM from two hospitals in the West Harima area of Japan and five hospitals in Kyoto City, Japan from 2012 to 2013. We estimated microbiological pNTM disease prevalence by multiplying all pTB cases in each area with the ratio of pNTM cases and pTB cases at the survey hospitals in each area. We administered a standardized questionnaire to 52 patients and 120 patients with pulmonary MAC [pMAC] disease at Ako City Hospital and Kyoto University Hospital, respectively


Results: the estimated prevalence of microbiological pNTM disease in the West Harima area [85.4/ 100,000 population-years] was significantly higher than that observed in Kyoto City [23.6/100,000 population-years; p < .001]. According to multiple logistic regression analysis, in Ako City Hospital, primary [activities directly related to natural resources] and secondary industries [construction, mining, and manufacturing primary industry produce; odds ratio [OR] = 4.79; 95% confidence interval [CI]= 1.49 - 14.0; p = .007] and soil exposure [OR= 13.6; 95% CJ= 4.94 - 45.26; p < .001] were associated with pMAC disease


Conclusion: environmental factors, both industrial structures associated with occupational dust and environmental soil exposure, could influence the regional variations in pNTM disease prevalence

3.
Japanese Journal of Cardiovascular Surgery ; : 76-79, 2012.
Article in Japanese | WPRIM | ID: wpr-363065

ABSTRACT

A 44-year-old man who received left ventricular assist device (LVAD) implantation for end-stage heart failure due to dilated cardiomyopathy suffered from mediastinitis. Computed tomography confirmed mediastinitis. His mediastinum was reopened and irrigated. Negative pressure wound therapy (NPWT) was applied to the wound without closing the chest. This system enabled the patient to receive early physical rehabilitation. One year after LVAD implantation, under NPWT, the patient could walk in the general ward, and was waiting for cardiac transplantation. We used some useful materials for NPWT including a coatable non-alcoholic film, flexible sealing sheet, soft exudate absorber, in order to control wound clean, keep air-tight, prevent damage to the skin and to reduce mediastinal instability. LVAD implantation is usually performed as a bridge to transplantation or recovery. One of the most critical complications is intractable mediastinitis. We described a successful infection control of LVAD related mediastinitis with the NPWT.

4.
Japanese Journal of Cardiovascular Surgery ; : 65-68, 2010.
Article in Japanese | WPRIM | ID: wpr-361977

ABSTRACT

The left ventricle assist device (LVAD) has become an important therapeutic option in the treatment of acute or chronic heart failure. It is usually used as bridge to transplantation or recovery. At present, destination therapy with LVAD has been a therapeutic option in patients with heart failure in whom transplantation is not indicated. We describe a patient, who received destination therapy with LVAD, and was able to go home temporarily. The patient was a 63-year-old man with low output syndrome after acute myocardial infarction. An LVAD (TOYOBO) was implanted at Oita University Hospital, however the patient suffered from MRSA mediastinitis 6 months later. He and his family wished for him to temporarily go home to Ibaraki. The patient, supported by LVAD, was transferred from Oita to Ibaraki by a regular commercial flight and ambulance. Rehabilitation training involved stretching, in-bed muscle strength training, maintaining a standing position, walking on flat ground with a walker and going up and down ramps. All training was measured at the patient's home. The patient was out of hospital for 5 hours, and this period was uneventful upon leaving hospital. The patient also took an active part in rehabilitation after discharge. This program can help to improve the quality of life (QOL) of patients with implanted LVADs for destination therapy.

SELECTION OF CITATIONS
SEARCH DETAIL