Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Japanese Journal of Cardiovascular Surgery ; : 254-259, 2014.
Article in Japanese | WPRIM | ID: wpr-375913

ABSTRACT

<b>Background</b> : The improvement in surgical results for congenital heart disease has resulted in an increase in the number of adult congenital heart disease (ACHD) cases. Some ACHD patients are known to develop thoracic aortic aneurysm (TAA) at a young age, so we examined TAA in ACHD patients presenting at our institute over a 10-year interval. <b>Methods</b> : From 2002 to 2011, we performed 32 cases of surgery for TAA in ACHD patients. We excluded 5 cases of adult bicuspid aortic valve, 2 of TAA with untreated congenital heart disease (CHD), 1 of Marfan syndrome with CHD, and 9 of coarctation of the aorta (CoA) repair for the same site ; 15 patients were included. <b>Results</b> : The male/female ratio was 13/2, and the age of reoperation was 33.3±10.8 years. The 15 ACHD patients included 5 cases of the tetralogy of Fallot (TOF), 4 of congenital aortic stenosis (AS), 3 of ventricular septal defect (VSD), and 1 of each CoA complex, polysplenia/double outlet right ventricle (DORV), and polysplenia/corrected transposition of the great arteries (cTGA). Twelve cases of root dilatation and 2 of ascending aortic aneurysm were observed and 10 cases were concomitant with moderate to severe aortic regurgitation. Thirteen cases underwent elective surgery and the other two cases were emergency surgeries : a Bentall procedure for type 2 acute aortic dissection of polysplenia/DORV, and a Bentall and right ventricular outflow reconstruction (RVOTR) for ascending aorta/right ventricle rupture due to Konno patch detachment in congenital AS. The 13 elective cases included 11 cases of Bentall procedure, 1 of ascending aorta/hemi arch replacement, and 1 of ascending aorta replacement. Concomitant procedures were 1 case of aortic valve replacement, 1 of mitral valve replacement, 1 of subaortic stenosis release, and 2 of RVOTR. Operation time was 572.8+/-101.4 min, cardiopulmonary bypass time was 295.8+/-100.2 min, and aorta clamp time was 188.1+/-58.8 min. One hospital death was observed in 1 emergency case due to methicillin-resistant <i>Staphylococcus aureus</i> (MRSA) sepsis, but no 30-day mortality was observed. Intensive care unit (ICU) stay was 9.4+/-10.1 days and hospital stay was 34.4+/-18.2 days. <b>Conclusion</b> : The most common ACHD found during TAA surgery in our institute was Tetralogy of Fallot. ACHD had various complications and restrictions for surgery but TAA surgery in ACHD patients was safe and feasible.

2.
Japanese Journal of Cardiovascular Surgery ; : 311-316, 2008.
Article in Japanese | WPRIM | ID: wpr-361854

ABSTRACT

In Japan, doctors inexperienced stent-graft new devices are required to secure agreement on criteria and choice of the device size in endovascular aneurysm repair (EVAR) from experienced doctors. It was hoped that strict patient selection might reduce the learning curve for initial successes in given procedures. In a leading center in Japan, a number of cases which were scheduled for operation at other institutes were evaluated anatomically. We surveyed the initial success of Zenith AAA system implantation in the remaining cases by inexperienced doctors and evaluated the results. This study aimed to verify the validity of strict patient selection in improving the success rate of inexperienced doctors. We enrolled 112 consecutive patients from 19 institutes, who were scheduled for repair between January and October in 2007. All patients were evaluated on the basis of a less-than-3mm reconstructed CT image. Mean patient age was 76±5.7 years. All cases satisfied the Zenith's anatomic prerequisites. Fifteen cases were excluded for various reasons, the major reason being insufficiency of the proximal landing zone (LZ) length, angle and contour. The second reason was difficulty to approach via the iliac artery. Ninety seven cases were included, of which 17 cases were low-risk candidates for EVAR. Medium-risk seventy two cases requiring some advice to avoid problems with device size, technique of implantation and choice of main-body side. Eight cases were high-risk, requiring the presence of an experienced surgeon. Excluded cases had significantly shorter proximal LZ, larger aortic diameters 15mm below the renal artery and tortuous access routes on preliminary measurement by inexperienced doctor. Perioperative mortality was 0%, while the major complications were injury to the iliac artery in one high-risk case and thromboembolism of the superficial femoral artery in another. Perioperative proximal type I endoleak occurred in 5 cases. In 3 of these cases, the endoleak was eliminated by implantation of a Palmatz stent. In the other 2 cases, it disappeared within a month without additional procedures. These cases had a significantly greater angle between the proximal LZ and the suprarenal aorta and significant amount of mural thromboses in the proximal LZ. Perioperative type III endoleak occurred in 3 cases. In all cases the endoleak was eliminated by additional procedure. Perioperative type II endoleak occurred 8 cases. In 3 of these cases, the endoleak disappeared within a month. In the 5 other cases, the endoleak did not disappear. Mid-term results showed iliac leg thromboembolism in one case and new type II endoleaks in 3 cases. Type II endoleak occurred in cases which had significantly greater angles between the proximal LZ and the aneurysm. The results which were evaluated in our center had excellent perioperative and mid-term outcomes. We think this evaluation system is effective for risk assessment and reduces the learning curve in EVAR. In anatomically marginal cases, it is possible for proximal type I endoleak and injury of the iliac artery to occur. It is impossible to exclude these marginal cases if treatment need for EVAR is a priority. In these cases, lessexperienced operators should be trained in troubleshooting techniques in advance.

3.
Annals of the Academy of Medicine, Singapore ; : 413-415, 2007.
Article in English | WPRIM | ID: wpr-250805

ABSTRACT

<p><b>INTRODUCTION</b>Obturator hernia is an important cause of small bowel obstruction and is associated with difficult diagnosis and high mortality.</p><p><b>MATERIALS AND METHODS</b>We reviewed 22 cases of intestinal obstruction due to obturator hernia that necessitated surgical intervention over the last 17 years and evaluated the changes in the number of patients based on the census data.</p><p><b>RESULTS</b>All cases were elderly females. The Howship-Romberg sign was present in 15 patients (68%). Computed tomography (CT) correctly diagnosed 13/15 (87%) of cases in which it was performed prospectively. The median time to surgery was 7.5+/-5.2 days for those patients with bowel resection, compared to 0.8+/-1.3 days for those without (P <0.05). The number of patients with obturator hernia has increased with an ageing society.</p><p><b>CONCLUSIONS</b>The rising incidence of obturator hernia is probably linked to an ageing society. CT of the pelvis was helpful in obtaining the correct diagnosis. The shorter the delay between admission and surgery, the lower the bowel resection rate. Laparotomy at an early stage is recommended in such patients as it leads to reduced morbidity and mortality.</p>


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Censuses , Hernia, Obturator , Diagnosis , Epidemiology , General Surgery , Japan , Epidemiology , Medical Audit , Outcome Assessment, Health Care , Population Dynamics , Retrospective Studies , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL