1.
Malaysian Journal of Medical Sciences ; : 40-49, 2015.
Article in English | WPRIM | ID: wpr-628294

ABSTRACT

Background: Optimisation of average glandular dose (AGD) for two-dimensional (2D) mammography is important, as imaging using ionizing radiation has the probability to induce cancer resulting from stochastic effects. This study aims to observe the effects of kVp, anode/filter material, and exposure mode on the dose and image quality of 2D mammography. Methods: This experimental study was conducted using full-field digital mammography. The entrance surface air kerma was determined using thermoluminescent dosimeter (TLD) 100H and ionization chamber (IC) on three types of Computerized Imaging Reference System (CIRS) phantom with 50/50, 30/70, and 20/80 breast glandularity, respectively, in the auto-time mode and auto-filter mode. The Euref protocol was used to calculate the AGD while the image quality was evaluated using contrast-to-noise ratio (CNR), figure of merit (FOM), and image quality figure (IQF). Results: It is shown that AGD  values in the auto-time mode did not decrease significantly with the increasing tube voltage of the silver filter (r = −0.187, P > 0.05) and  rhodium filter (r = −0.131, P > 0.05) for all the phantoms. The general linear model showed that AGD for all phantoms had a significant effect between different exposure factors [F (6,12.3) = 4.48 and mode of exposure F (1,86) = 4.17, P < 0.05, respectively] but there is no significant difference between the different anode/filter combination [F (1,4) = 0.571]. Conclusion: In summary, the 28, 29, and 31 kVp are the optimum kVp for 50%, 30%, and 20% breast glandularity, respectively. Besides the auto-filter mode is suitable for 50%, 30%, and 20% breast glandularity because it is automatic, faster, and may avoid error done by the operator.

2.
Indian J Med Sci ; 2013 Jan-Feb; 67(1) 23-28
Article in English | IMSEAR | ID: sea-149548

ABSTRACT

Background: Two digital mammography systems, based on different physical concepts, have been introduced in the last few years namely the full-field digital mammography (FFDM) system and computed radiography-based mammography using digital storage phosphor plate (DSPM). Aims: The objective of this study was to compare the image quality for DSPM and FFDM using a grading scale based on previously published articles. Materials and Methods: This comparative diagnostic study was done for 5-month duration at the Breast Clinic. The system used was the Lorad Selenia FFDM system and the Mammomat 3000 Nova DSPM system. The craniocaudal and mediolateral oblique projections were done on both breast on 58 asymptomatic women using both DSPM and FFDM. The mammograms were evaluated for eight criteria of image quality: Tissue coverage, compression, exposure, contrast, resolution, noise, artifact, and sharpness by two independent radiologists. Statistical Analysis: Wilcoxon Signed Rank Test and Weighted Kappa. Results: FFDM was rated significantly better (P < 0.05) for five aspects: Tissue coverage, compression, contrast, exposure, and resolution and equal to DSPM for sharpness, noise, and artifact. Conclusion: FFDM was superior in five aspects and equal to DSPM for three aspects of image quality.

3.
Malaysian Journal of Medical Sciences ; : 52-59, 2012.
Article in English | WPRIM | ID: wpr-627950

ABSTRACT

Background: Digital mammography is slowly replacing screen film mammography. In digital mammography, 2 methods are available in acquiring images: digital storage phosphor plate and full-field digital mammography. The aim of this study was to compare the image quality acquired from the 2 methods of digital mammography in the detection of breast cancer. Methods: The study took place at the National Cancer Society, Kuala Lumpur, and followed 150 asymptomatic women for the duration of 1 year. Participating women gave informed consent and were exposed to 4 views from each system. Two radiologists independently evaluated the printed images based on the image quality criteria in mammography. McNemar’s test was used to compare the image quality criteria between the systems. Results: The agreement between the radiologists for the digital storage phosphor plate was ĸ = 0.551 and for full-field digital mammography was, ĸ = 0.523. Full-field digital mammography was significantly better compared with the digital storage phosphor plate in right and left mediolateral oblique views (P < 0.05) in the detection of microcalcifications, which are early signs of breast cancer. However, both systems were comparable in all other aspects of image quality. Conclusion: Digital mammography is a useful screening tool for the detection of early breast cancer and ensures better prognosis and quality of life.