Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 11-15, 2019.
Article in Chinese | WPRIM | ID: wpr-734308

ABSTRACT

Objective To investigate the value of "one-stop" scanning of coronary and head and neck CTA in patients with normal body mass index (18 kg/m2 ≤ BMI ≤ 25 kg/m2) using low tube voltage (80 kVp).Methods In a retrospective analysis 80 patients with normal body mass index who had completed "one-stop" scanning of coronary and head and neck CTA were divided into A and B groups according to different scanning method,and 40 consecutive cases were selected in each group.Scanning parameters of group A and group B were tube voltage 80 kV,coronary CTA tube current 550 mA,head and neck CTA tube current 500 mA,and tube voltage 100 kV,coronary CTA tube current 450 mA,head and neck CTA tube current 400 mA separately.Subjective evaluation and objective evaluation were performed on the image quality of the two groups.CT values of coronary artery and head and neck CTA trunk branch vessel,contrast-to-noise ratio (CNR),image noise (SD) and effective dose between the two groups were compared.Results The image quality of both groups met the diagnostic requirements,and there was no statistically significant difference in subjective scores between two groups (P>0.05).The CT values of coronary arteries,the main branches of the head and neck (the common carotid artery,the internal carotid artery) and SD of head and neck CTA were significantly different between two groups (t=4.737,6.552,3.359,2.165,2.685,4.617,P<0.05).There was no statistically significant difference in SD of coronary CTA,CT values and CNR between head and neck vessels (middle cerebral artery) in group A and group B (P>0.05).The effective dose of coronary CTA in group A (1.16±0.20) mSy was reduced by 51.1% than that in group B (2.37±0.77) mSv.The effective dose of head and neck CTA in group A (0.37±0.03) mSv was reduced by 47.9% than that in group B (0.71 ± 0.17) mSv.Conclusions The image quality with subjective evaluation met the diagnostic requirements when using a low-tube voltage for "one-stop"scanning of coronary and head and neck CTA.The CNR values were basically consistent with the conventional scanning method,and the patient effective dose was reduced by about 50%.

2.
Chinese Medical Journal ; (24): 2906-2915, 2017.
Article in English | WPRIM | ID: wpr-324718

ABSTRACT

<p><b>BACKGROUND</b>Debate on treatment for young patients with coronary artery disease still exists. This study aimed to investigate the intermediate- and long-term outcomes between coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) in patients aged 18-45 years with diabetes mellitus (DM).</p><p><b>METHODS</b>Between January 2006 and March 2016, a total of 2018 DM patients aged 18-45 years including 517 cases of CABG and 1501 cases of PCI were enrolled in the study. Using propensity score matching (PSM), 406 patients were matched from each group. The intermediate- and long-term data were collected. The primary end point of this study was long-term death. The secondary end points included long-term major adverse cardiovascular and cerebrovascular events (MACCEs), stroke, angina, myocardial infarction (MI), and repeat revascularization.</p><p><b>RESULTS</b>Before PSM, the in-hospital mortality was 1.2% in the CABG group and 0.1% in the PCI group, with statistically significant difference (P < 0.0001). The 10-year follow-up outcomes including long-term survival rate and freedom from MACCEs were better in the CABG group than those in the PCI group (97.3% vs. 94.5%, P = 0.0072; 93.2% vs. 86.3%, P < 0.0001), but CABG group was associated with lower freedom from stoke compared to PCI group (94.2% vs. 97.5%, P = 0.0059). After propensity score-matched analysis, these findings at 10-year follow-up were also confirmed. Freedom from MACCEs was higher in CABG group compared to PCI group, but no significant difference was observed (93.1% vs. 89.2%, P = 0.0720). The freedom from recurrent MI was significantly higher in CABG patients compared with PCI patients (95.6% vs. 92.5%, P = 0.0260). Furthermore, CABG was associated with a higher rate of long-term survival rate than PCI (97.5% vs. 94.6%, P = 0.0403). There was no significant difference in the freedom from stroke between CABG and PCI groups (95.3% vs. 97.3%, P = 0.9385). The hospital cost was greater for CABG (13,936 ± 4480 US dollars vs. 10,926 ± 7376 US dollars, P < 0.0001).</p><p><b>CONCLUSIONS</b>In DM patients aged 18-45 years, the cumulative survival rate, and freedom from MI and repeat revascularization for CABG were superior to those of PCI. However, a better trend to avoid stroke was observed with PCI.</p>

3.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 1304-1307, 2017.
Article in Chinese | WPRIM | ID: wpr-667825

ABSTRACT

Adolescent idiopathic scoliosis(AIS)is a complex three-dimensional spinal deformity,characterized by lateral curvature and vertebral rotation.The medical imaging techniques are essential for determination of severity of scoliotic spine, prediction of progression and assistance in the decision-making process of treatment for scoliosis, including radiograph, stereoradiography, computed tomography, magnetic resonance imaging and ultrasound.This paper reviewed their application from the view of measure parameters,reliability and va-lidity,as well as merits and demerits.It is possible to assess the three-dimensional nature of scoliosis in the future.

4.
Chinese Journal of Surgery ; (12): 615-617, 2011.
Article in Chinese | WPRIM | ID: wpr-285675

ABSTRACT

<p><b>OBJECTIVE</b>To determine the clinical characteristics and outcomes of redo CABG.</p><p><b>METHODS</b>The outcomes of 42 consecutive patients who underwent redo CABG from January 2002 to December 2010 was analyzed. There were 29 males and 13 females, aging from 46 to 78 years old with a mean of (61.2 ± 2.1) years. Off-pump CABG was applied for 31 patients and on-pump CABG for 11 patients. There were 1 patient underwent concomitant aortic valve replacement and 1 patient underwent aortic root and right aortic arch replacement respectively.</p><p><b>RESULTS</b>Three patients died of right ventricle rupture, heart failure and multiple system organ failure respectively and the perioperative mortality rate was 4.8%. The post-operatively mechanical ventilation time varied from 9 to 27 h with a mean of (17 ± 7) h. There was no residual angina and perioperative myocardial infarction in the remaining patients who were all discharged uneventfully. Intraoperative 6 patients had accepted intraaortic balloon counterpulsation. During the follow-up from 6 months to 4.5 years for 38 patients, which showed no evidence of recurrent angina and postoperative coronary CT angiography in 12 patients showed the patency of grafts is good.</p><p><b>CONCLUSION</b>Satisfactory outcome of redo coronary artery bypass grafting can be achieved if proper indication were choose and reasonable management were performed.</p>


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Cardiopulmonary Bypass , Coronary Artery Bypass , Coronary Restenosis , General Surgery , Reoperation , Treatment Outcome
5.
Chinese Journal of Gastrointestinal Surgery ; (12): 27-30, 2011.
Article in Chinese | WPRIM | ID: wpr-237175

ABSTRACT

<p><b>OBJECTIVE</b>To study the feasibility of MRI of human colon adenocarcinoma cell line (Lovo) labeled with superparamagnetic iron oxide(SPIO) nanoparticles in vitro.</p><p><b>METHODS</b>Lovo cells (5 × 10(5) and 1 × 10(6)) were cultured in medium containing different SPIO nanoparticles (50 microl and 500 microl). Transmission electron microscopy was used to observe cellular ultrastructure and to determine the uptake and distribution of particles in Lovo cells at 1-, 3-, 6-hours. MRI of Lovo cells was performed with T1WI, T2WI sequences. Unlabeled cells were used as controls.</p><p><b>RESULTS</b>Uptake of SPIO nanoparticles occurred within 6 hours. On T1 weighted imaging, there was no significant difference in signal intensity between the experimental groups and the control group. On T2 weighted imaging, there was no significant difference in signal intensity between the experimental groups and the control group after culture of 1 h. Signal intensity began to decrease in 1 × 10(6) Lovo cells labeled with 500 microl SPIO nanoparticle after 3 hours culture. Signal intensity decreased in all the experimental groups after 6 hours culture.</p><p><b>CONCLUSION</b>Human colon adenocarcinoma cell line (Lovo) can be labeled with SPIO nanoparticles, and the labeled cells can be imaged with MRI equipment.</p>


Subject(s)
Humans , Adenocarcinoma , Pathology , Cell Line, Tumor , Colonic Neoplasms , Pathology , Iron , Magnetic Resonance Imaging , Methods , Magnetics , Nanoparticles , Oxides , Pilot Projects , Staining and Labeling , Methods
6.
Chinese Journal of Surgery ; (12): 1913-1915, 2008.
Article in Chinese | WPRIM | ID: wpr-275920

ABSTRACT

<p><b>OBJECTIVE</b>To summarize the clinic characteristics and effect of surgical repair of ruptured aortic sinus aneurysm.</p><p><b>METHODS</b>From September 1997 to September 2007, 43 patients with ruptured aortic sinus aneurysm underwent surgical procedures. There were 32 male and 11 female patients. The age ranged from 11 to 50 years old with a mean of (29.0 +/- 11.5) years old. The origins of rupture were the right coronary sinus in 34 patients and the noncoronary sinus in 9 patients. The aneurysms ruptured into the right ventricle in 30 patients, the right atrium in 8 patients, the right ventricle and right atrium in 3 patients, and the ventricular septum and then the right ventricle in 2 patients. Associated cardiac anomalies included ventricular septal defect in 26 patients, aortic regurgitation in 15 patients, infectious endocarditis in 8 patients, tricuspid regurgitation in 6 patients, atrial septum defect in 4 patients, mitral valve regurgitation in 2 patients, patent ductus arteriosus in 2 patients, and pulmonary valve vegetation in 1 patient. All the patients underwent the repair of ruptured aortic sinus aneurysm and correction of associated anomalies with cardiopulmonary bypass.</p><p><b>RESULTS</b>There were no deaths after the operation and during the follow-up. The complications, including acute heart failure and III atrioventricular block, occurred in 5 patients. Follow-up was 6 to 120 months with a mean of (68.0 +/- 17.7) months. Two patients underwent reoperation for aortic valve replacement at the 6(th) and 8(th) year after the first operation. There were 2 patients which the aortic regurgitation deteriorated from grade I to II.</p><p><b>CONCLUSIONS</b>Repair of ruptured aortic sinus aneurysm presents a satisfactory result. Aggressive treatment in early time, prevention of post-operative complications and long-term follow-up are recommended in the treatment for patients of ruptured aortic sinus aneurysm with infectious endocarditis and aortic regurgitation.</p>


Subject(s)
Adolescent , Adult , Child , Female , Humans , Male , Middle Aged , Aortic Rupture , General Surgery , Follow-Up Studies , Retrospective Studies , Sinus of Valsalva , General Surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL