Rev. bras. cir. cardiovasc ; 22(2): 184-191, abr.-jun. 2007. ilus
Article in Portuguese | LILACS | ID: lil-461758

ABSTRACT

OBJETIVO: O objetivo deste estudo é avaliar, ao ecodopplercardiograma (ECO), o funcionamento do aparelho valvar mitral, em pacientes submetidos ao implante de cordas padronizadas de pericárdio bovino (CP de PB) para substituição de cordas tendíneas rotas ou alongadas com grau importante de afilamento. MÉTODO: Foram implantadas CP de PB em 23 pacientes portadores de insuficiência mitral por ruptura das cordas tendíneas ou cordas alongadas com afilamento importante. A idade variou de 23 a 85 anos (média de 62 anos). A causa mais freqüente foi a degeneração fibroelástica em 20 (87,0 por cento) pacientes. As CP de PB foram confeccionadas em conjunto, unidas em suas extremidades por duas hastes reforçadas com poliéster formando um monobloco. As CP de PB medem dois mm de largura e distam entre si, paralelamente, por três mm. Cada conjunto CP de PB possui um medidor correspondente, variando seu comprimento entre 20 a 35 mm. Em 17 (73,9 por cento) pacientes foram implantadas as CP de PB na cúspide posterior e, em seis (26,1 por cento), na cúspide anterior. Todos os pacientes foram avaliados no pós-operatório pelo ECO, com tempo médio de seguimento de até seis meses. RESULTADOS: O ECO no pós-operatório demonstrou ausência de refluxo em 11 (47,8 por cento) pacientes, refluxo discreto em oito (34,8 por cento) e refluxo discreto/moderado em três (13,0 por cento). A abertura e mobilidade da valva mitral eram normais nos 22 pacientes sobreviventes. CONCLUSÃO: O ECO demonstrou boa funcionalidade do aparelho valvar mitral nos pacientes submetidos ao implante das CP de PB para substituição de cordas tendíneas rotas ou alongadas e afiladas com adequada coaptação das cúspides.


OBJECTIVE: The objective of this study was to evaluate, using echocardiography, the functioning of the mitral valve apparatus in patients submitted to standardized bovine pericardium chordae implantation to substitute ruptured chordae tendineae or elongated chordae with a significant degree of thinning. METHOD: Standardized bovine pericardium chordae were implanted in 23 patients with mitral valve insufficiency due to ruptured or elongated chordae with significant thinning. The ages of the patients varied from 23 to 84 years old (mean 62 years old). The most common cause was fibroelastic degeneration affecting 20 (87.0 percent) patients. The standardized bovine pericardium chordae were manufactured in sets connected at both ends by two polyester-reinforced rods thereby forming a single block. The bovine pericardium chordae measure 2 mm wide with 3 mm between the chordae. The sets of bovine pericardium chordae are produced in lengths varying from 20 to 35 mm. In 17 (73.9 percent) patients bovine pericardium chordae were implanted in the posterior cusp and in 6 (26.1 percent) in the anterior cusp. All the patients were evaluated in the postoperative period by echocardiography after a mean follow-up of six months. RESULTS: The echocardiography in the postoperative period demonstrated an absence of reflux in 11 (47.8 percent) patients, slight reflux in 8 (34.8 percent) and slight to moderate reflux in 3 (13.0 percent). The opening and mobility of the mitral valve was normal in the 22 surviving patients. CONCLUSION: The echocardiography demonstrated good functioning of the mitral valve apparatus in patients submitted to the implantation of standardized bovine pericardium chordae to substitute ruptured chordae tendineae or elongated chordae with a significant degree of thinning.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Chordae Tendineae , Mitral Valve Insufficiency/surgery , Prostheses and Implants , Biocompatible Materials , Prospective Studies
3.
Arq. bras. cardiol ; 36(5): 345-8, maio 1981. tab
Article in Portuguese | LILACS, SES-SP | ID: lil-63582

ABSTRACT

Sessenta e cinco pacientes portadores de hipertensäo arterial sistêmica foram estudados do ponto de vista ecocardiográfico. Os resultados obtidos foram comparados aos de 32 indivíduos normotensos, com ecocardiograma normais. O grupo hipertenso apresentou: maior freqüência de hipertrofia septal assimétrica (HSA) e vibraçöes diastólicas da valva mitral; aumento do átrio esquerdo, do diâmetro da aorta, da espessura diastólica do septo interventricular, da espessura diastólica da parede posterior do ventrículo esquerdo; dimimuiçäo da velocidade média de contraçäo circunferencial do ventrículo esquerdo e da percentagem de espessamento sistólico da parede posterior do ventrículo esquerdo


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Echocardiography , Hypertension/physiopathology