Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
J. appl. oral sci ; 31: e20220421, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1421898

ABSTRACT

Abstract The demands for dental materials continue to grow, driven by the desire to reach a better performance than currently achieved by the available materials. In the dental restorative ceramic field, the structures evolved from the metal-ceramic systems to highly translucent multilayered zirconia, aiming not only for tailored mechanical properties but also for the aesthetics to mimic natural teeth. Ceramics are widely used in prosthetic dentistry due to their attractive clinical properties, including high strength, biocompatibility, chemical stability, and a good combination of optical properties. Metal-ceramics type has always been the golden standard of dental reconstruction. However, this system lacks aesthetic aspects. For this reason, efforts are made to develop materials that met both the mechanical features necessary for the safe performance of the restoration as well as the aesthetic aspects, aiming for a beautiful smile. In this field, glass and high-strength core ceramics have been highly investigated for applications in dental restoration due to their excellent combination of mechanical properties and translucency. However, since these are recent materials when compared with the metal-ceramic system, many studies are still required to guarantee the quality and longevity of these systems. Therefore, a background on available dental materials properties is a starting point to provoke a discussion on the development of potential alternatives to rehabilitate lost hard and soft tissue structures with ceramic-based tooth and implant-supported reconstructions. This review aims to bring the most recent materials research of the two major categories of ceramic restorations: ceramic-metal system and all-ceramic restorations. The practical aspects are herein presented regarding the evolution and development of materials, technologies applications, strength, color, and aesthetics. A trend was observed to use high-strength core ceramics type due to their ability to be manufactured by CAD/CAM technology. In addition, the impacts of COVID-19 on the market of dental restorative ceramics are presented.

2.
Braz. dent. sci ; 26(1): 1-9, 2023. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1411424

ABSTRACT

Objective: Evaluate the mechanical properties of experimental adhesive models with different photoinitiators (PI) polymerized by LED units of different power densities. Material and Methods: Three groups of adhesive models based on HEMA/BisGMA (45/55) were prepared in association with different PI combinations: G2 (control) ­ 2 PI: 0.5% CQ, 0.5% EDMAB; G3 - 3 PI: 0.5% CQ; 0.5% DMAEMA, 0.5% DPIHP; G4 - 4 PI: 0.5% CQ; 0.5% EDMAB; 0.5% DMAEMA; 0.5% DPIHP. The three formulations were polymerized at two different LED power densities: 550 mW/cm2 and 1200 mW/cm2. The degree of conversion (DC) of adhesive monomers was monitored in situ through the FTIR for 600 s. Specimens were prepared for each formulation for analysis mong adhesive systems (G2

Objetivo: Avaliar as propriedades mecânicas de modelos adesivos experimentais com diferentes fotoiniciadores (PI) polimerizados por unidades de LED de diferentes densidades de energia. Material e Métodos: Três grupos de modelos adesivos baseados em HEMA/BisGMA (45/55) foram preparados em associação com diferentes combinações de PI: G2 (controle) ­ 2 PI: 0,5% CQ, 0,5% EDMAB; G3 - 3PI: 0,5% CQ; 0,5% DMAEMA, 0,5% DPIHP; G4 - 4 PI: 0,5% CQ; 0,5% EDMAB; 0,5% DMAEMA; 0,5% DPIHP. As três formulações foram polimerizadas em duas densidades de potência de LED: 550 mW/cm2 e 1200 mW/cm2. O grau de conversão (DC) dos monômeros adesivos foi monitorado in situ através do FTIR durante 600 s. Amostras foram preparadas para cada formulação para análise de resistência à flexão (FS), módulo de elasticidade (ME), sorção (SOR) e solubilidade (SOL). Os dados foram submetidos aos testes ANOVA 2-fatores e Tukey (5%). Resultados: DC: houve diferença significativa entre os sistemas adesivos (G2

Subject(s)
Radiation , Dentin-Bonding Agents , Light-Curing of Dental Adhesives , Photoinitiators, Dental
3.
Braz. dent. sci ; 24(2): 1-9, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1177588

ABSTRACT

Objective: The purpose of the present study was to synthesize and characterize lithium disilicate glass-ceramics through the Li2O-SiO2system for determining the most satisfactory sintering parameter by evaluating the crystalline composition, microstructure and mechanical properties. Material and methods: The glass-ceramics were prepared from a glass precursor by means of the melting/cooling technique with a composition of 33.33 Li2O and 66.67 SiO2 (mol.%). The specimens were compressed by the uniaxial pressing technique and three different thermal treatments were used for sintering: 850 °C (Group 1), 900 °C (Group 2), and 950 °C (Group 3), which were determined based on the differential scanning calorimetry (DSC) result. The glass-ceramics were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), Archimedes method, microhardness and biaxial flexural strength analyses. Results: The results regarding XRD predominantly showed lithium disilicate phase for all the heat treatments performed. Moreover, grains with a needle form were more predominantly observed in the SEM images for Group 3, as well as a higher densification and consequently higher mechanical properties. In contrast, Group 1 presented the lowest mechanical properties and densification, as well as the highest porosity. Conclusion: The present study demonstrated how extremely important it is to follow the heat treatment recommended by the manufacturers of ceramics, including time and temperature, which possess direct effects in the crystalline phase formation, as well as in the material's microstructure and mechanical properties (AU)


Objetivo: O presente estudo teve como objetivo sintetizar e caracterizar uma vitrocerâmica de dissilicato de lítio através do sistema Li2O-SiO2para determinar o parâmetro de sinterização mais satisfatório através da avaliação da composição cristalina, microestrutura e propriedades mecânicas. Material e Métodos: As vitrocerâmicas foram preparadas a partir de um vidro precursor pelo método fusão/resfriamento utilizando a composição de 33.33 Li2O e 66.67 SiO2 (mol.%). As amostras foram prensadas utilizando uma técnica de prensagem uniaxial e três tratamentos térmicos diferentes foram utilizadas para sinterização: 850 °C (Grupo 1), 900 °C (Grupo 2), e 950 °C (Grupo 3), que foram determinados através do resultado da análise diferencial de calorimetria. As vitrocerâmicas foram caracterizadas através das análises de difração de raios X (DRX), microscopia eletrônica de varredura (MEV), métodos de Arquimedes, microdureza e ensaio de flexão biaxial. Resultados: Os resultados de DRX mostraram predominantemente a fase de dissilicato de lítio para todos os tratamentos realizados. Além disso, grãos com forma agulhada foram mais predominantemente observados por MEV no grupo 3, assim como uma densificação maior e consequentemente valores maiores das propriedades mecânicas. Em contraste, o grupo 1 apresentou os menores valores de propriedades mecânicas e densificação, e também a maior porosidade. Conclusão: O presente estudo demonstrou como é extremamente importante seguir o tratamento térmico recomendado pelos fabricantes de cerâmica, incluindo tempo e temperatura, que possuem efeitos diretos na formação da fase cristalina, assim como na microestrutura do material e propriedades mecânicas. (AU)


Subject(s)
X-Ray Diffraction , Microscopy, Electron, Scanning , Crystallization
4.
Braz. dent. sci ; 24(3): 1-7, 2021. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1281904

ABSTRACT

Objective: The aim of the study was to fabricate and morphologically characterize ultrafine Polyetherimide fibers (PEI) associated with Polymethylmethacrylate (PMMA) ­ PP (group formed by the association of PEI with PMMA), produced by the electrospinning process. Material and Methods: A solution of PEI (0.562 g) + PMMA (0.377 g) dissolved in 2.5 mL of chloroform, 0.85 mL of Dimethylformamide (DMF) and 0.85 mL of 1.1.2.2 Tetrachloroethane (TCE) was prepared. For the electrospinning process, different continuous voltages (10 to 18 kV) and two different distances (8 and 12 cm) between the needle tip and the collecting apparatus were used, giving rise to 6 distinct groups of ultrafine fibers (PP 1 to 6) that were observed in Scanning Electron Microscopy to check for defects and calculate the average diameter of the fibers. Results: The best parameter, the parameter that was most effective for the production of fibers, observed was subjected to Energy Dispersion X-ray Spectroscopy (EDS), X-ray Diffraction (XRD) and Contact Angle Analysis tests. The data were analyzed using the ANOVA and Tukey test (p <0.05). From the comparative analysis of the pre-established parameters, the pattern of PP4 ultrafine fibers was shown to be more effective. Conclusion: The PP4 standard (13 kV ­ 12 cm) had an average diameter of 0.37 µm. An adequate parameter to electrospinning was able to produce ultrafine fibers of PMMA/PEI (AU)


Introdução: O objetivo do estudo foi sintetizar e caracterizar morfologicamente fibras ultrafinas de Polieterimida (PEI) associadas ao Polimetilmetacrilato (PMMA) - PP (grupo formado pela associação de PEI com PMMA), produzidas pelo processo de eletrofiação. Material e Métodos: Foi preparada uma solução de PEI (0,562 g) + PMMA (0,377 g) dissolvido em 2,5 mL de clorofórmio, 0,85 mL de Dimetilformamida (DMF) e 0,85 mL de 1.1.2.2 Tetracloroetano (TCE). Para o processo de eletrofiação, foram utilizadas diferentes tensões contínuas (10 a 18 kV) e duas distâncias diferentes (8 e 12 cm) entre a ponta da agulha e o aparelho coletor, dando origem a 6 grupos distintos de fibras ultrafinas (PP 1 a 6) que foram observados em Microscopia Eletrônica de Varredura para verificar defeitos e calcular o diâmetro médio das fibras. Resultados: O melhor parâmetro, o parâmetro mais eficaz para a produção de fibras, observado foi submetido aos testes de Espectroscopia de Dispersão de Energia (EDS), Difração de Raios X (DRX) e Análise do Ângulo de Contato. Os dados foram analisados pela ANOVA e teste de Tukey (p <0,05). A partir da análise comparativa dos parâmetros pré-estabelecidos, o padrão das fibras ultrafinas PP4 mostrou-se mais eficaz. Conclusão: O padrão PP4 (13 kV - 12 cm) apresentou diâmetro médio de 0,37 µm. Um parâmetro adequado para eletrofiação foi capaz de produzir fibras ultrafinas de PMMA / PEI. (AU)


Subject(s)
Microscopy, Electron, Scanning , Polymethyl Methacrylate , Spectroscopy, Electron Energy-Loss
5.
Journal of Stroke ; : 388-400, 2021.
Article in English | WPRIM | ID: wpr-892956

ABSTRACT

Background@#and Purpose The influence of stroke etiology on outcomes after endovascular thrombectomy (EVT) is not well understood. We aimed to investigate whether stroke etiology subgrouped as large artery atherosclerosis (LAA) and cardiac embolism (CE) influences outcomes in large artery occlusion (LAO) treated by EVT. @*Methods@#We included EVT treated LAO stroke patients registered in the Safe Implementation of Treatment in Stroke (SITS) thrombectomy register between January 1, 2014 and September 3, 2019. Primary outcome was successful reperfusion (modified Treatment in Cerebral Infarction 2b-3). Secondary outcomes were symptomatic intracranial hemorrhage (SICH), 3-month functional independence (modified Ranking Scale 0–2) and death. Multivariable logistic regression models were used for comparisons. In addition, a meta-analysis of aggregate data from the current literature was conducted (PROSPERO, ID 167447). @*Results@#Of 7,543 patients, 1,903 (25.2%) had LAA, 3,214 (42.6%) CE, and 2,426 (32.2%) unknown, other, or multiple etiologies. LAA patients were younger (66 vs. 74, P<0.001) and had lower National Institutes of Health Stroke Scale score at baseline (15 vs. 16, P<0.001) than CE patients. Multivariable analyses showed that LAA patients had lower odds of successful reperfusion (odds ratio [OR], 0.70; 95% confidence interval [CI], 0.57 to 0.86) and functional independence (OR, 0.74; 95% CI, 0.63 to 0.85), higher risk of death (OR, 1.44; 95% CI, 1.21 to 1.71), but no difference in SICH (OR, 1.09; 95% CI, 0.71 to 1.66) compared to CE patients. The systematic review found 25 studies matching the criteria. The meta-analysis did not find any difference between etiologies. Conclusions From the SITS thrombectomy register, we observed a lower chance of reperfusion and worse outcomes after thrombectomy in patients with LAA compared to CE etiology, despite more favorable baseline characteristics. In contrast, the meta-analysis did not find any difference between etiologies with aggregate data.

6.
Journal of Stroke ; : 388-400, 2021.
Article in English | WPRIM | ID: wpr-900660

ABSTRACT

Background@#and Purpose The influence of stroke etiology on outcomes after endovascular thrombectomy (EVT) is not well understood. We aimed to investigate whether stroke etiology subgrouped as large artery atherosclerosis (LAA) and cardiac embolism (CE) influences outcomes in large artery occlusion (LAO) treated by EVT. @*Methods@#We included EVT treated LAO stroke patients registered in the Safe Implementation of Treatment in Stroke (SITS) thrombectomy register between January 1, 2014 and September 3, 2019. Primary outcome was successful reperfusion (modified Treatment in Cerebral Infarction 2b-3). Secondary outcomes were symptomatic intracranial hemorrhage (SICH), 3-month functional independence (modified Ranking Scale 0–2) and death. Multivariable logistic regression models were used for comparisons. In addition, a meta-analysis of aggregate data from the current literature was conducted (PROSPERO, ID 167447). @*Results@#Of 7,543 patients, 1,903 (25.2%) had LAA, 3,214 (42.6%) CE, and 2,426 (32.2%) unknown, other, or multiple etiologies. LAA patients were younger (66 vs. 74, P<0.001) and had lower National Institutes of Health Stroke Scale score at baseline (15 vs. 16, P<0.001) than CE patients. Multivariable analyses showed that LAA patients had lower odds of successful reperfusion (odds ratio [OR], 0.70; 95% confidence interval [CI], 0.57 to 0.86) and functional independence (OR, 0.74; 95% CI, 0.63 to 0.85), higher risk of death (OR, 1.44; 95% CI, 1.21 to 1.71), but no difference in SICH (OR, 1.09; 95% CI, 0.71 to 1.66) compared to CE patients. The systematic review found 25 studies matching the criteria. The meta-analysis did not find any difference between etiologies. Conclusions From the SITS thrombectomy register, we observed a lower chance of reperfusion and worse outcomes after thrombectomy in patients with LAA compared to CE etiology, despite more favorable baseline characteristics. In contrast, the meta-analysis did not find any difference between etiologies with aggregate data.

7.
The Journal of Advanced Prosthodontics ; : 385-395, 2021.
Article in English | WPRIM | ID: wpr-918846

ABSTRACT

PURPOSE@#To characterize the microstructure of three yttria partially stabilized zirconia ceramics and to compare their hardness, indentation fracture resistance (IFR), biaxial flexural strength (BFS), and fatigue flexural strength. @*MATERIALS AND METHODS@#Disc-shaped specimens were obtained from 3Y-TZP (Vita YZ HT), 4Y-PSZ (Vita YZ ST) and 5Y-PSZ (Vita YZ XT), following the ISO 6872/2015 guidelines for BFS testing (final dimensions of 12 mm in diameter, 0.7 and 1.2 ± 0.1 mm in thicknesses). Energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and scanning electron microscopy (SEM) analyses were performed, and mechanical properties were assessed by Vickers hardness, IFR, quasi-static BFS and fatigue tests. @*RESULTS@#All ceramics showed similar chemical compositions, but mainly differed in the amount of yttria, which was higher as the amount of cubic phase in the diffractogram (5Y-PSZ > 4Y-PSZ > 3Y-TZP). The 4Y- and 5Y-PSZ specimens showed surface defects under SEM, while 3Y-TZP exhibited greater grain uniformity on the surface. 5Y-PSZ and 3Y-TZP presented the highest hardness values, while 3Y-TZP was higher than 4Y- and 5Y-PSZ with regard to the IFR. The 5Y-PSZ specimen (0.7 and 1.2 mm) showed the worst mechanical performance (fatigue BFS and cycles until failure), while 3Y-TZP and 4Y-PSZ presented statistically similar values, higher than 5Y-PSZ for both thicknesses (0.7 and 1.2 mm). Moreover, 3Y-TZP showed the highest (1.2 mm group) and the lowest (0.7 mm group) degradation percentage, and 5Y-PSZ had higher strength degradation than 4Y-PSZ group. @*CONCLUSION@#Despite the microstructural differences, 4Y-PSZ and 3Y-TZP had similar fatigue behavior regardless of thickness. 5Y-PSZ had the lowest mechanical performance.

8.
Braz. dent. j ; 30(5): 511-518, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1039148

ABSTRACT

Abstract This study evaluated the influence of zirconia surface finishes on the wear of an enamel analogue. 40 zirconia discs were divided into four groups: control (without finish); glazed; polished; polished and glazed. All samples were subjected to wear against steatite antagonists. The specimens underwent roughness, topographic, scanning electron microscopy (SEM) and wettability analyses. Quantitative wear measurements were performed on both steatites and discs. To measure wear of steatites the weight before and after the test and the diameter after the test were used. Profilometer measurements were performed to determine the wear on discs. Roughness, volumetric wear and mass loss were analyzed using the Kruskal-Wallis and Dunn tests (5%), while contact angle values were analyzed with One-way ANOVA and Tukey tests (5%). The polished group had the lowest roughness means, being statistically different from the other groups (p-value=0.0001). The glazed group presented the lowest steatite volumetric wear (p-value=0.0001), but not statistically different from the polished and glazed group, whereas these groups presented the highest zirconia volumetric wear, with statistically different (p-value=0.0002) compared to the others. SEM showed irregularities on the control groups surface, grooves on the polished group, and a homogeneous surface for the glazed group with a few pores. All groups presented contact angles lower than 90 degrees, characterizing hydrophilic surfaces. It can be concluded that just glazed zirconia caused less wear on the antagonist when compared to no finish and polished zirconia.


Resumo Este estudo avaliou a influência dos acabamentos superficiais da zircônia no desgaste de um análogo de esmalte. 40 discos de zircônia foram divididos em quatro grupos: controle (sem acabamento); glazeado; polido; polido e glazeado. Todas as amostras foram submetidas ao desgaste contra antagonistas de esteatita. Os espécimes foram submetidos à análise de rugosidade, topografia, microscopia eletrônica de varredura (MEV) e análise de molhabilidade. Medidas quantitativas de desgaste foram realizadas nos antagonistas e nos discos de zircônia. Para medir o desgaste das esteatitas, foi mensurado o peso antes e depois do desgaste e o diâmetro após o teste. A análise de perfilometria mensurou o desgaste dos discos. Rugosidade, desgaste volumétrico e perda de massa foram analisados pelos testes de Kruskal-Wallis e Dunn (5%), enquanto os valores de ângulo de contato foram analisados com os testes One-way ANOVA e Tukey (5%). O grupo polido apresentou as menores médias de rugosidade, sendo estatisticamente diferente dos demais grupos (p-valor=0,0001). O grupo glazeado apresentou o menor desgaste volumétrico do antagonista (p-valor=0,0001), mas não foi estatisticamente diferente do grupo polido e glazeado, enquanto que esses grupos apresentaram o maior desgaste volumétrico da zircônia, com diferença estatisticamente diferente (p-valor=0,0002) em comparação com os outros. MEV mostrou irregularidades na superfície do grupo controle, sulcos no grupo polido e uma superfície homogênea para o grupo glazeado, com poucos poros. Todos os grupos apresentaram ângulos de contato menores que 90 graus, caracterizando superfícies hidrofílicas. Dentro das limitações deste estudo in vitro, é possível concluir que zircônia glazeada causou menos desgaste ao antagonista quando comparada a zircônia sem tratamento ou polida. Além disso, não foi encontrada diferença no desgaste do antagonista para os grupos de zirconia polida e controle.


Subject(s)
Zirconium , Dental Porcelain , Surface Properties , Materials Testing , Dental Polishing
9.
Hig. aliment ; 33(288/289): 3037-3041, abr.-maio 2019. tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1482509

ABSTRACT

O vinho, uma fonte de resveratrol, é uma bebida que pode beneficiar as formulações de produtos alimentícios, promovendo um possível incremento da qualidade nutricional e dos atributos sensoriais. Este trabalho objetivou desenvolver e analisar (físico-químico e sensorial) sobremesas lácteas (mousses) enriquecidas pelo uso do vinho como ingrediente. Observou-se que as três mousses apresentaram conteúdos de proteínas, carboidratos e lipídios. Sobre a análise sensorial, médias expressivas (acima de 7,0) foram observadas para os atributos aparência, sabor e textura, indicando uma considerável aceitação desses produtos entre os consumidores. Conclui-se ser possível desenvolver mousses de vinhos tinto, rosé e branco com parâmetros físico-químicos adequados. Além disso, esses produtos demonstraram resultados relevantes nos testes de aceitação.


Subject(s)
Consumer Behavior , Chemical Phenomena , Dairy Products , Wine , Identity and Quality Standard for Products and Services , Meals
10.
Braz. dent. j ; 27(6): 693-699, Nov.-Dec. 2016. tab, graf
Article in English | LILACS | ID: biblio-828065

ABSTRACT

Abstract Polyetheretherketone (PEEK) is a material suitable for frameworks of fixed dental prostheses. The effect of different surface treatments on the bond strength of PEEK bonded to human dentin was evaluated. One hundred PEEK cylinders (3 mm×3 mm) were divided into five groups according to surface treatment: silica coating, sandblasting with 45 μm Al2O3 particles, etching with 98% sulfuric acid for 5, 30 and for 60 s. These cylinders were luted with resin cement onto 50 human molars. First, each tooth was embedded in epoxy resin and the buccal dentin surface was exposed. Then, two delimited dentin areas (Æ:3 mm) per tooth were etched with 35% phosphoric acid and bonded with a two-step self-priming adhesive system. After the luting procedure the specimens were stored in water (24 h/37 °C). Shear bond strength (SBS) was tested using a universal testing machine (crosshead speed 0.5 mm/min; load cell 50 kgf) and failure types were assessed. Stress data (MPa) were analyzed using the Kruskal-Wallis test. Comparison of the proportions of different failure types was performed using the Bonferroni method (p<0.05). Kruskal-Wallis demonstrated that differences among groups were not significant (p=0.187). Mean SBS were as follows: silica coating, 2.12±1.12 MPa; sandblasting, 2.37±0.86 MPa; sulfuric acid 5 s, 2.28±1.75 MPa; sulfuric acid 30 s, 1.80±0.85 MPa; sulfuric acid 60 s, 1.67±0.94 MPa. Adhesive and mixed failures were predominant in all groups. Both physical and chemical surface treatments produced adhesion between PEEK, resin cement and dentin.


Resumo O poli-éter-éter-cetona (PEEK) é um material indicado para as estruturas de próteses parciais fixas. O efeito de diferentes tratamentos de superfície na resistência de união entre PEEK e dentina humana foi avaliado. Cem cilindros de PEEK (3 mm×3 mm) foram divididos em cinco grupos de acordo com tratamento de superfície: silicatização, jateamento com partículas de Al2O3 45 µm, condicionamento com ácido sulfúrico 98% por 5, 30 e 60 s. Esses cilindros foram cimentados com cimento resinoso em cinquenta molares humanos. Primeiro, cada dente foi incluído em resina epóxica e a superfície dentinária vestibular foi exposta. Depois, duas áreas (Æ:3 mm) em dentina/por dente foram delimitadas, condicionadas com ácido fosfórico a 35% e receberam aplicação de um sistema adesivo de dois passos. Após o procedimento de cimentação, as amostras foram armazenadas em água (24 h/37 °C). A resistência da união ao cisalhamento (SBS) foi testada em uma máquina universal de ensaios (velocidade 0,5 mm/min; célula de carga 50 kgf), e foram avaliados os tipos de falha. Os dados de tensão (MPa) foram analisados pelo teste de Kruskal-Wallis. A comparação das percentagens de diferentes tipos de falha foi realizada utilizando o método de Bonferroni (p<0,05). O teste de Kruskal-Wallis demonstrou que as diferenças entre os grupos não foram significantes (p=0,187). As médias de SBS foram: silicatização, 2,12±1,12 MPa; jateamento, 2,37±0,86 MPa; ácido sulfúrico por 5 s, de 2,28±1,75 MPa; ácido sulfúrico por 30 s, 1,80±0,85 MPa, ácido sulfúrico por 60 s, 1,67±0,94 MPa. Falhas adesivas e mistas foram predominantes em todos os grupos. Ambos tratamentos de superfície, físicos e químicos, promoveram adesão entre PEEK, cimento resinoso e dentina.


Subject(s)
Humans , Acid Etching, Dental/methods , Dental Bonding , Ketones , Polyethylene Glycols , Dental Cements , Dental Stress Analysis , Materials Testing , Microscopy, Electron, Scanning
11.
Periodontia ; 22(3): 70-74, 2012. graf
Article in English | LILACS, BBO | ID: lil-728150

ABSTRACT

Gingivitis is an inflammation of dental protective tissues and biofilm accumulation is the main etiologic factor of this disease. Due to the antimicrobial and anti-inflammatory actions shown by Ocimum gratissimum (OCG), this study aimed at evaluating the antiplaque and antigingivitis effect of 3% OCG gel in human gingivitis. Thirty volunteers were selected and subdivided in 2 groups (n=15): control (placebo gel+brushing), and test (3% OCG gel+brushing). All participants received mouth guards to apply the gel 3 times/day during 15 days. Visible Plaque Index (VPI= mean±sd %), Turesky Index (TUR= mean scores±sd) and Gingival bleeding Index (GI= mean±sd %) were performed on days 0 and 15. All the individuals, with mean age of 21.8 years, being 50% females, completed the study. In both groups, control and test, there was a reduction (p<0.05) on VPI of 51.9% and 65.1%, respectively, when compared to each respective baseline. Test showed lower VPI (p<0.05) when compared to control. TUR index corroborated VPI findings. Both experimental groups presented a decrease by 68.4% when compared to its respective baseline. Control and test groups showed reduction on GI of 59.38% and 80.9%, respectively, when compared to baseline. A greater reduction was observed in the use of 3% gel when compared to control (p<0.05). The present study indicates that 3% OCG gel associated to brushing showed antiplaque and antigingivitis effect, being important as an adjuvant to plaque-induced gingivitis treatment


Subject(s)
Gingivitis , Dental Plaque
12.
Braz. j. pharm. sci ; 48(3): 427-433, July-Sept. 2012. tab
Article in English | LILACS | ID: lil-653456

ABSTRACT

The aim of this study was to present the implications of the use of herbs during pregnancy, pointing out those that should be avoided during this condition because of their abortifacient and/or teratogenic potential. We carried out searches in the databases ScienceDirect, Scielo and Google Scholar, adopting as criteria for inclusion: book chapters and/or complete articles (with abstract), available in English, Portuguese or Spanish, published from 1996 to in 2011. After a pre-selection of 83 articles, 49 bibliographies were used in the manufacturing end of the article, where 25 were from the Scielo database, 18 from ScienceDirect and 6 from Google Scholar. From the articles studied, we identified the four most commonly used plants as emmenagogue/abortifacient agents by patients of the Department of Prenatal SUS: senne, arruda, boldo and buchinha-do-norte or cabacinha. Thus, we conclude that people often adhere to the maxim "if it's natural, it does no harm" in their rational use of natural products, without the right guidance, believing that these products are safe to use. This usage is even more worrisome among the elderly, pregnant women and children. Regarding the safety of these products, some information and reliable data are scarce or contradictory.


Este trabalho busca as implicações atuais sobre o uso de plantas medicinais durante a gravidez, alertando sobre aquelas que devem ser evitadas nesse período por serem potencialmente abortivas e/ou teratogênicas. Para tanto, foram realizadas buscas nas bases de dados Sciencedirect, Scielo e Google scholar, adotando-se como critérios de inclusão capítulos de livros e/ou artigos completos (com abstract) e disponíveis, em português, inglês ou espanhol, publicados de 1996 a 2011. Após uma pré-seleção de 83 artigos, 49 bibliografias foram utilizadas na confecção final do artigo, sendo 25 provenientes da base de dados Scielo, 18 do Sciencedirect e 06 do Google scholar. A partir dos artigos estudados, identificaram-se as quatro plantas mais utilizadas como emenagogas/abortivas por pacientes do Serviço de Pré-Natal do SUS: senne, arruda, boldo e buchinha-do-norte ou cabacinha. Assim, é possível concluir que, muitas vezes, a população se utiliza da máxima "se é natural, não faz mal" para fazer uso irracional de produtos naturais, sem a correta orientação, acreditando que esses produtos sejam incapazes de provocar qualquer dano. Esse uso é ainda mais preocupante quando realizado por idosos, gestantes e crianças. Em relação à segurança do uso desses produtos, algumas informações e dados confiáveis ainda são escassos ou contraditórios.


Subject(s)
Plants, Medicinal/toxicity , Pregnancy , Biological Products/analysis , Menstruation-Inducing Agents/analysis
SELECTION OF CITATIONS
SEARCH DETAIL