Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 614-618, 2019.
Article in Chinese | WPRIM | ID: wpr-755018

ABSTRACT

Objective To analyze the dosimetric and delivery efficiency differences between IMRT plans based on Halcyon and Trilogy Accelerator for left side breast cancer.Methods A total of 10 patients with left side breast cancer based on the Trilogy platform were retrospectively analyzed.For each patient,plan based on Halcyon was redesigned using Eclipse Version 15.1 TPS.In order to evaluate plan quality,dose coverage of target and dose to organs at risk,monitor unit efficiency,segment size and delivery time were compared.Results Halcyon treatment platform could meet the clinical objective.Dose distribution of the target volume had no significant difference with the Trilogy plans (P>0.05).Volumes receiving 10 Gy,20 Gy and D of the left lung were significantly reduced(Z=-2.22--1.78,P<0.05).V5 of heart for Halcyon and Trilogy was(27.80±7.66)% and (23.18±8.19)%,respectively(Z=-0.71,P<0.05),while D was (7.03± 1.8)Gy and(7.11±2.40)Gy,respectively(P>0.05).Halcyon increased the monitor unit from 1 526.2±227.7 by Trilogy to 1 770.5±383.9(Z=-0.71,P<0.05),but decreased the delivery time from (12.38± 1.49) min by Trilogy to (3.01 ±0.28) min (Z =-3.42,P< 0.05).Conclusion Halcyon treatment platform can meet the clinical requirements,reduce dose to normal tissue with high delivery efficiency.

2.
Chinese Journal of Clinical Oncology ; (24): 399-405, 2019.
Article in Chinese | WPRIM | ID: wpr-754432

ABSTRACT

Objective: To investigate the impact of portal hypertention with hypersplenism of different severity and splenectomy on prognosis of hepatocellular carcinoma (HCC). Methods: We retrospectively analyzed the clinical data of 403 patients with HCC who met the Milan criteria and received radical treatment in Tianjin Third Central Hospital from January 2008 to January 2018. Cox propor-tional risk regression analysis was performed for parameters such as platelet levels (PLT), albumin-bilirubin (ALBI) grade, aspartate ami-notransferase-to-platelet ratio index (APRI), and post-sinusoidal resistance (PSR). HCC patients with severe hypersplenism were as-signed into two groups according to treatment method: radical treatment for HCC alone and radical treatment for HCC plus splenecto-my. Clinical data were compared, and the two groups were evaluated using the Kaplan-Meier survival analysis method. Results: Univar-iate and multivariate analyses showed that PLT was an independent risk factor for overall survival (OS) and disease-free survival (DFS) in patients with HCC. OS curves differed significantly with different PLT among patients with HCC (P=0.013). Furthermore, parameters of portal hypertension in cirrhosis, such as PSR, APRI, and ALBI grade, were risk factors for HCC prognosis. The degree of portal hyper-tension and hypersplenism, liver function, and tumor-node-metastasis stage did not differ between the two groups (P>0.05). Survival analysis showed significantly longer OS in the radical treatment plus splenectomy group (P=0.025). Following were the 1-, 3-, and 5-year survival rates: radical treatment alone group 100% , 98.2% , and 68.5% and radical treatment plus splenectomy group. 97.1% , 79.4%, and 56.8%, respectively. DFS did not differ between the two groups (P=0.326). Conclusions: Clinical parameters, such as PLT, PSR, APRI, and ALBI grade, are important prognostic factors in HCC patients with portal hypertension and hypersplenism. Radical treat-ment for HCC plus splenectomy can improve OS in HCC patients within the Milan criteria with severe hypersplenism.

3.
Chinese Pharmacological Bulletin ; (12): 318-321, 2019.
Article in Chinese | WPRIM | ID: wpr-857332

ABSTRACT

Pristimeim, as one major active chemical component of traditional Chinese medicine Celastrus aculeatus Men., has been reported to have pharmacological activities such as broad spectrum anti-tumor and anti-rheumatoid arthritis in recent years. In this article, we review the research articles of pristimerin on the characteristics and molecular mechanism of its pharmacological effects, aiming to make a reference for new drug development and clinical application.

4.
Chinese Journal of Immunology ; (12): 301-305, 2018.
Article in Chinese | WPRIM | ID: wpr-702722

ABSTRACT

Primary Sj?gren′s syndrome(pSS)is a chronic autoimmune disease which is characterized by exocrine gland dam-age.Studies have found that pSS is associated with a variety of autoantibodies,including anti-Ro/SSA,-La/SSB,-M3R,-α-fodrin,-AD-AMTS13,-NA-14,-IFN-γ,-REG Iα,-MDM2.In this paper,we reviewed the progress of autoantibodies in the diagnosis,disease prediction and pathogenesis of pSS in recent years,so as to provide new ideas for pSS clinical and scientific research.

5.
Chinese Journal of Digestive Surgery ; (12): 729-739, 2018.
Article in Chinese | WPRIM | ID: wpr-699191

ABSTRACT

Objective To systematically evaluate the safety and feasibility of enhanced recovery after surgery (ERAS) in perioperative management of pancreatectomy.Methods Literatures were researched using CNKI,Wanfang database,VIP database,PubMed,Cochrane Library,Embase from January 1990 to March 2018 with the key words including "快速康复外科,加速康复外科,胰腺切除术,胰十二指肠切除术,惠普而术,ERAS,enhanced recovery,fast track,pancreatic surgery,pancreatectomy,Whipple,pancreatoduodenectomy,pancreatoduodenal resection".The cohort study about ERAS in elective pancreatic surgery or pancreaticoduodenectomy were received and enrolled.The patients using ERAS in perioperative management and using traditional perioperative management were respectively allocated into the ERAS group and control group.Two reviewers independently screened literatures,extracted data and assessed the risk of bias.Count data were described as odds ratio (OR) and 95% confidence interval (CI).Weighted Mean Difference (WMD) was used as a consolidated statistics for measurement data that were measured using the same tool,and standardized mean difference (SMD) was used as a consolidated statistics for measurement data that were measured using the different tools.The heterogeneity of the studied was analyzed using the I2 test.Results Nineteen retrospective cohort studies were enrolled in the Meta analysis,and total sample size was 3 699 patients,including 1 823 in the ERAS group and 1 876 in the control group.The results of Meta analysis showed that there were statistically significant differences in the time of postoperative nasogastric tube removal,time for postoperative solid diet intake,time of postoperative defecation recovery,incidence of postoperative overall complications,incidence of postoperative delayed gastric emptying,incidence of postoperative intra-abdominal infection,duration of postoperative hospital stay and hospital expenses between ERAS group and control group (WMD=-1.70,-3.61,-0.86,OR =0.65,0.60,0.70,WMD=-4.64,SMD=-0.48,95%CI:-2.97--0.42,-4.70--2.53,-1.01--0.71,0.52-0.81,0.45-0.80,0.54-0.91,-5.91--3.38,-0.77--0.18,P < 0.05).There was no statistically significant difference in the operation time,volume of intraoperative blood loss,incidence of postoperative pancreatic fistula,incidence of postoperative wound infection,readmission rate,reoperation rate and mortality between ERAS group and control group (WMD=-9.73,-14.39,OR=0.85,0.72,1.05,0.81,0.74,95%CI:-34.24-14.78,-116.96-88.17,0.72-1.01,0.46-1.14,0.83-1.32,0.58-1.13,0.53-1.02,P>0.05).The results of subgroup analysis showed that heterogeneity of data was from eastern and western countries.Conclusion ERAS in the perioperative management of pancreatectomy is safe and feasible,it can also promote postoperative recovery of patients and reduce incidence of complications and financial burden.

6.
Chinese Journal of Radiological Medicine and Protection ; (12): 837-840, 2014.
Article in Chinese | WPRIM | ID: wpr-466194

ABSTRACT

Objective To investigate the impact of gantry angles on the position accuracy of buildin multi-leaf collimator (MLC) during static (step & shoot) intensity modulated radiotherapy (IMRT).Methods The position accuracy of MillenniumTM 60 pairs multi-leaf collimator (MLC) in Varian 23EX medical linear accelerator during 10 fractions of treatments with static intensity modulated radiotherapy (IMRT) was retrospectively analyzed by resolving dynamic therapy log files and MLC planning files.The single leaf position deviation and gap deviation of each MLC pairs were compared between expected values and actual outcomes.The impact of gantry angle on MLC position accuracy was also investigated with paired t-test between vertical and horizontal beams.Results All the MLC position deviations ranged within ± 1.0 mm,while the gap deviations were at the range of ± 1.5 mm.The statistical standard deviation of MLC position deviations among fractions was less than 0.06 mm.After all the 60 pairs of MLC leaves were taken into account,the M LC position deviation in the field of 103° was smaller than in the field of 0° (t =58.74,P < 0.01),but there was no significant difference between 257° and 0°,while only the moving leaves were put into consideration,the MLC position deviation in the field of 103° was still smaller than in the field of 0°,but the MLC position deviation in the field of 257° was slightly higher than in thefield of 0° (t =41.95、-4.47,P < 0.01).Conclusions The MillenniumTM 60 pairs MLC in Varian 23EX medical linear accelerator meets the mechanical quality assurance requirement during static IMRT treatments.The MLC positioning showed stable repeatability among treatment fractions.Although the MLC position accuracy is slightly affected by gravity from different gantry angles,but still meets the mechanical QA requirements for medical linear accelerator.This dynamic analysis method is expected to be a novel strategy which may improve the existing QA protocols.

7.
Journal of Southern Medical University ; (12): 299-304, 2013.
Article in Chinese | WPRIM | ID: wpr-322059

ABSTRACT

<p><b>OBJECTIVE</b>To evaluate the protective effect of licoflavone on gastric mucosa in rats with chronic superficial gastritis and explore the possible mechanism.</p><p><b>METHODS</b>SD rat models of chronic superficial gastritis was established by intragastric administration of 0.02% ammonia and long-term irregular diet. The rat models were then randomized into model group, vitacoenzyme group and 3 licoflavone groups of high, medium, and low doses. After 30 days of treatment, the gastric histopathology, mucosal lesions, scanning electron microscopy, mucin function production by the gastric mucosa epithelial cells, serum PGE(2) level and gastric microcirculation were assessed to evaluate the protective effect of licoflavone on gastric mucosa.</p><p><b>RESULTS</b>Compared with normal control rats, the rat models of chronic superficial gastritis showed significantly higher gastric mucosal injury rate, histopathological scores and gastric mucin content. Licoflavone significantly ameliorated gastric pathology and increased serum PGE(2) level, enhanced acidic mucin secretion by the epithelial cells, and improved gastric microcirculation in the rat models.</p><p><b>CONCLUSION</b>Licoflavone feeding suppresses gastric mucosa injury, protects and restores the injured mucosa in rats with chronic superficial gastritis, and these effects are related with the up-regulation of serum PGE(2) level.</p>


Subject(s)
Animals , Female , Male , Rats , Chronic Disease , Dinoprostone , Blood , Epithelial Cells , Bodily Secretions , Flavones , Pharmacology , Gastric Mucosa , Pathology , Gastritis , Pathology , Microcirculation , Mucins , Bodily Secretions , Rats, Sprague-Dawley
8.
Chinese Journal of Clinical Oncology ; (24): 1436-1440, 2013.
Article in Chinese | WPRIM | ID: wpr-440790

ABSTRACT

Objective:This study aimed to detect the special methylation profile in peripheral blood for hepatocellular carcinoma (HCC). Methods:The methylation status of 12 tumor suppressor genes (TSGs) in the plasma of 55 HCCs and 54 chronic liver diseases (CLDs) was tested by methylation-specific PCR (MSP). Results:In HCC, the methylation frequencies were 78.18%in APC, 63.64%in cyclin D2, 58.18% in TFPI2, 49.09% in DKK3, 49.09% in GSTP1, 47.27% in p16, 40.00% in Sigma 14-3-3, 18.18% in SFRP2, 16.36% in ppENK, 9.09% in DKK2, 7.27% in NPTX2, and 5.45% in LHX1. In CLD, the methylation frequencies were 27.78% in APC, 22.22%in cyclin D2, 7.41%in TFPI2, 3.70%in DKK3, 16.67%in GSTP1, 37.04%in p16, 37.04%in Sigma 14-3-3, 11.11%in SFRP2, 20.37%in ppENK, 7.41%in DKK2, 7.41%in NPTX2, and 9.26%in LHX1. The methylation frequencies of APC, cyclin D2, TFPI2, DKK3, and GSTP1 were higher in HCC than in CLD (P<0.01). The methylation index (MI) of the five-gene methylation profile was statistically higher in HCC (median, 0.6;IQR, 0.4-0.8) than CLD (median, 0.2;IQR, 0-0.2) (P<0.01). In HCC, MI was statistically related to the patient's age. Older patients with HCC had a higher MI. No significant correlation was observed between MI and other clinicopathological data. Moreover, MI was not related to the disease free survival and the overall survival in HCC. Conclusion:This five-gene methylation profile may be a promising biomarker for the assistant diagnosis of HCC.

9.
Chinese Journal of Radiological Medicine and Protection ; (12): 289-293, 2012.
Article in Chinese | WPRIM | ID: wpr-427015

ABSTRACT

Purpose To investigate the dosimetric differences among RapidArc (RA) plans which were designed on different target volumes in hepatocellular carcinoma (HCC).Methods A total of 10 HCC patients underwent 3D-CT scan under free breathing ( FB),end inspiration hold ( EIH ) associated with active breath coordinator (ABC) and 4D-CT scan.The 4D-CT were sorted into 10 sets of CT images according to respiratory cycle.The gross tumor volume (GTV) was manually contoured on different CT images.The individual internal gross target volume ( IGTV1 ) was obtained from 4D-CT,and the individual margins from GTVFB to IGTV1.IGTV2 were obtained from GTVFB using individual margins.The planned target volumes (PTV-1,PTV-2,PTV-3 and PTV-4 ) were obtained from GTVFB,IGTV1,IGTV2 and GTVEIA applying different margins.The RA plans (RA1,RA2,RA3 and RA4 ) were designed from different PTVs,and for RA1,RA2 and RA3 the simple 358° arc were used,while three 135° arcs were used for RA4.The dosimetric differences were compared.Results The PTV-1 and PTV-3 were larger than PTV-2 and PTV-4; the mean values of PtV-1/PTV-2 and PTV-1/PTV-4 were 2.5 and 1.9,respectively.There were no significant differences in conformal index,homogeneity index,maximum dose,and minimum dose of PTV among 4 RA plans.The irradiation dose of normal liver of RA3 and RA4 were 8.23 Gy and 7.63 Gy respectively,both significantly lower than those of RA1 and RA2 (10.21 Gy,9.62 Gy,x2 =10.68,P <0.05 ),and the V30of RA3 and RA4 were 5.24% and 5.05% respectively,both significantly lower than those of RA1 and RA2 (7.76%,6.12%,x2 =14.76,P < 0.05 ).There were no significant differences in irradiation doses of stomach and duodenum among different plans.Conclusions Using 4D-CT or ABC technology with RapidArc in HCC can define the target volume accurately and achieve prefect dose distribution sparing more normal liver volume,compared to the traditional margins.4D-CT and ABC play similar roles in sparing normal liver.

10.
Chinese Journal of Radiological Medicine and Protection ; (12): 575-578, 2011.
Article in Chinese | WPRIM | ID: wpr-422322

ABSTRACT

Objective To evaluate the anatomic changes and dosimetric variations of patients with nasopharyngeal carcinoma (NPC) during the course of simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) by comparison of the dosimetric differences with or without replanning.Methods Twelve cases with NPC treated with SIB-IMRT underwent repeated CT scans after 20- 25 fractions of the initiation of therapy.The original treatment plan ( Plan1 ) based on the first CT scan ( CT1 ) and the second IMRT plan (Plan 2) based on the second CT scan (CT2) were calculated with an inverse planning system (Pinnacle3,Philips Medical System).In addition,the hybrid IMRT plan,Planl (CT2),was generated by deformable registration with MIMVISTA software,and the doses in Plan 1 ( CT1 ) and Plan 2 ( CT2 ) were accumulated based on CT2.The dosimetric differences were compared among the Plan 1 ( CT1 ),Plan 1 (CT2) and Plan 1 + 2(CT2).Results Compared with CT1,the mean volumes of the right and left parotid glands in the CT2 were significantly smaller by ( 24.6 ± 11.9 ) % and ( 35.1 ± 20.1 ) %,respectively.Compared with Plan 1 ( CT1 ),the dose received by 95% of the target ( D9s ) to PGTV,PTV1 and PTV2,and mean dose (D ) to PGTV,and PTV2 were all significantly lower in the Plan 1 (CT2),indicating that the doses to targets decreased without replanning.With repeated CT and replanning after 25 fractions as shown in Plan 1 + 2 (CT2),the doses to targets would be improved.The doses to normal tissue were increased without replanning,although no statistical significance was observed.In 5 of 12 cases,the doses to the spinal cord and brainstem exceeded the constraint without replanning,while the corresponding values decreased with replanning.Conclusions During the course of IMRT for cases with NPC,the volumes of the targets and parotid glands decrease significantly.Mid-treatment CT scanning and replanning should be recommended to ensure adequate doses to the targets and safe doses to the normal tissues.

11.
Chinese Journal of Radiological Medicine and Protection ; (12): 456-459, 2011.
Article in Chinese | WPRIM | ID: wpr-424200

ABSTRACT

Objective To evaluate the dose distribution of target volume and normal tissues in forward intensity modulated radiotherapy (fIMRT) and inverse intensity modulated radiotherapy (iIMRT) modes for breast cancer after radical mastectomy.Methods Both fIMRT and iIMRT plans were developed for 10 patients with breast cancer after radical mastectomy.On each patient's CT images the supraclavicular area, chest wall, and internal mammary area were delineated.The prescription dose was 50 Gyin 25fractions.In the fIMRT plan X-ray irradiation at the dose of 6 MV was adopted for the supraclavicular and the chest wall areas and electron irradiation at the dose of 9 - 12 MeV was adopted for the internal mammary area, and the doses of cold and hot spots were adjusted according to the fitting doses of these 3 regions.In the iIMRT plan the supraclavicular area, chest wall, and internal mammary area were taken asa whole target, 6 MV X-rays was used, and inverse optimal design was performed.The dose distribution oftarget volume and normal tissues, conformal index (CI) , and heterogeneous index (HI) , and acceleratormonitor unit (MU) were analyzed using dose-volume histogram (DVH)for the two intensity modulated modes.Results The maximum dose of PTV of the iIMRT plan was significantly lower than that of the fIMRT plan(t = -3.23,P <0.05), the minimum dose and V95% of PTV of the iIMRT were significantly higher than those of the fIMRT plan(t = 4.08, -2.69, both P <0.05).The CI level of the iIMRT plan was significantly higher than that of the fIMRT plan and the HI level of the iIMRT plan was significantly lower than that of the fIMRT plan (t = -3.13, 2.74, both P <0.05).There were not significant differences in V10, V20, V25, V30, and Dmean of the ipsilateral lung between these 2 groups.However, the V15 of ipsilateral lung of the iIMRT group was significantly lower by 4.2% than that of the fIMRT group (t= 3.2, P < 0.05).There were not significant differences in the mean dose (Dmean) and V30 of heart, and Dmean of contralateral lung and contralateral breast between these 2 groups.Conclusions Compared with fIMRT, the iIMRT plan results in more PTV coverage, higher conformity index, and more homogeneous dose distribution, with lower dose upon the lung at the affected side, and better protection of the contralateral lung, heart, and breast.

12.
Clinical Medicine of China ; (12): 718-721, 2010.
Article in Chinese | WPRIM | ID: wpr-386692

ABSTRACT

Objective To study clinical value of percutaneous intrabiliary expandable metallic biliary stenting (EMBS) for treatment of malignant obstructive jaundice. Methods One hundred and sixty patients with malignant obstructive jaundice were treated with EMBS ( EMBS group) . Thirty patients underwent only external drainage by PTCD were recruited as control. The patency rate of stent,decline of bilirubin and the complication were analyzed retrospectively. Both groups were followed up for three months. The Kaplan-Meier method (log-rank test) was used to compare the survival period between the two groups. Results Anorexia,skin pruritus and color of urine alleviated at a certain degree in both groups.In the EMBS group,plasma total bilirubin was(218. 78 ±2. 29) μmol/L pre-stent,and decreased to (134. 90 ±2. 34), (83. 18 ±2.40) , (40. 74 ±2. 29) μmol/L at the 7,14,21 days after the stenting, respectively; direct bilirubin was (128.82 ±2.40) μmol/L pre-stent, and decreased to (81.28 ± 2. 34), (51. 29 ±2. 45) and (25. 70 ±2.40)μmol/L at the 7,14,21 days after the stenting ( P =0. 000). In the PTCD group,plasma total bilirubin was (223. 57 ± 2. 58) μmol/L pe-stent, and decreased to ( 145. 68 ± 2. 57 ) ,(87.57 ±2.58) ,(38.65 ±2. 20) μmol/L at the 7,14,21 days after the stenting,respectively;direct bilirubin was (127. 6 ±2. 59)μmol/L pre-stent,and decreased to (79. 78 ±2. 70) ,(58. 36 ±2. 46) and (29.46 ±2. 20)μmol/L at the 7,14,21 days after the stenting,respectively ( P <0.001 ). No significant difference was found between the two groups at any time point ( P > 0. 05). Complications occurred in 34 patients in the EMBS group and the incidence rate was 20. 62% . Two or more complications occurred in 9 patients. In the PTCD group, complications occurred in 60.00% of the patients. In the EMBS group, 14 patients were failed to follow up, and 136 died. The median length was 214 days. In the PTCD group,all patients were followed up and all died,with a median length of survival of 75. 5 days. The survival analysis showed that the EMBS group survived longer than the PTCD group (P =0. 000). Conclusions EMBS placement showed better effect than PTCD. Compared to PTCD, internal drainage of metallic stents lead few complications and faster recover, and can improve the life quality and prolong survival time of patient with malignant obstructive jaundice. The placement of metallic stents is recommended as a preference for palliative therapy of malignant biliary obstruction.

13.
Chinese Journal of Radiation Oncology ; (6): 355-357, 2010.
Article in Chinese | WPRIM | ID: wpr-389066

ABSTRACT

ObjectiveTo study the efficacy of using multileaf collimators with different position and different degree in the treatment of nasopharyngeal carcinoma (NPC) using intensity-modulated radiotherapy techniques.Methods Ten patients withNPC were administered andanalyzed.Thepenumbra characteristics, dose of target, and radiation conformal indexes (CI) of mode T1 and mode T2 were measured and compared using dose volume histogram generated by Varian Eclipse three-dimensional planning computer system. Mode T1 :The angles of seven coplanar beams were 0°, 52°, 106°, 160°, 212°, 258°and 308°,respectively. There were no restriction on the position and degree of multileaf collimators. Parameters were set and optimized. Mode T2 :The beam angles and the parameters were as same as mode T1. According to the actual situations, the position and the degree of the multileaf collimators were changed. Then thedose optimization was performed. Results Target dose coverage in both mode T1 and T2 could be clinically accepted, and the CI were 0. 82 and 0. 83(t = -0. 25, P =0. 815). The maximum dose reductions in the lens, eyes, optic nerves and corneas were 28. 7% (t = 4. 80, P = 0. 000), 2. 7% (t = 2. 99, P = 0. 021),1.4%(t= 1.05,P=0.032), and 30.5% (t=2.99,P=0. 020), respectively. However, the mean dose and V35 of the parotid were increased by 0. 6% (t = - 2. 82, P = 0. 043) and 9.9% (t = - 2. 05, P =0. 038). ConclusionsOpimization of multileaf collimators can reduce the scattering and leaking rays. Compared with mode T1 ,controlling the position and degree of multileaf collimators could reduce the radiation dose to the eyes and optic-nerves, especially to the lens.

14.
Chinese Medical Journal ; (24): 509-513, 2009.
Article in English | WPRIM | ID: wpr-311832

ABSTRACT

<p><b>BACKGROUND</b>The lung functional status could be displayed on lung perfusion images. With the images, the radiotherapy plans of lung cancer could be guided to more optimized. This study aimed to assess quantitatively the impact of incorporating functional lung imaging into 3-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiation therapy (IMRT) planning for non-small cell lung cancer (NSCLC).</p><p><b>METHODS</b>Ten patients with NSCLC who had undergone radiotherapy were included in this study. Before radiotherapy, each patient underwent CT simulation and lung perfusion imaging with single photon emission computed tomography (SPECT). The SPECT images were registered with simulation planning CT and used to contour functional lung (lung-F) and non-functional lung (lung-NF). Two 3DCRT plans and two IMRT plans were designed and compared in each patient: two anatomic plans using simulation CT alone and two functional plans using SPECT-CT in addition to the simulation CT. Dosimetric parameters of the four types of plans were compared in terms of tumor coverage and avoidance of normal tissues. Total radiation dose was set at 66 Gy (2 Gy x 33 fractions).</p><p><b>RESULTS</b>In incorporating perfusion information in 3DCRT and IMRT planning, the reductions on average in the mean doses to the functional lung in the functional plan were 168 cGy and 89 cGy, respectively, compared with those in the anatomic plans. The median reductions in the percentage of volume irradiated with > 5 Gy, > 10 Gy, > 20 Gy, > 30 Gy and > 40 Gy for functional lung in the functional plans were 6.50%, 10.21%, 14.02%, 22.30% and 23.46% in 3DCRT planning, respectively, and 3.05%, 15.52%, 14.16%, 4.87%, and 3.33% in IMRT planning, respectively. No greater degree of sparing of the functional lung was achieved in functional IMRT than in 3DCRT.</p><p><b>CONCLUSION</b>Function-guided 3DCRT and IMRT plannings both appear to be effective in preserving functional lung in NSCLC patients.</p>


Subject(s)
Humans , Carcinoma, Non-Small-Cell Lung , Diagnostic Imaging , Pathology , Radiotherapy , Radiography , Radiotherapy, Conformal , Methods , Radiotherapy, Intensity-Modulated , Methods , Tomography, Emission-Computed, Single-Photon , Methods
15.
Chinese Medical Journal ; (24): 1311-1315, 2009.
Article in English | WPRIM | ID: wpr-292719

ABSTRACT

<p><b>BACKGROUND</b>Prevention is presently the only available method to limit radiation-induced lung morbidity. A good predictor is the key point of prevention. This study aimed to investigate if [(18)F]2-fluoro-2-deoxyglucose (FDG) uptake changes in the lung after radiotherapy could be used as a new predictor for acute radiation pneumonitis (RP).</p><p><b>METHODS</b>Forty-one patients with lung cancer underwent FDG positron emission tomography/computed tomography (FDG-PET/CT) imaging before and after radiotherapy. The mean standardized uptake value (SUV) was measured for the isodose regions of 0 - 9 Gy, 10 - 19 Gy, 20 - 29 Gy, 30 - 39 Gy, 40 - 49 Gy. The mean SUV of these regions after radiotherapy was compared with baseline. The mean SUV in patients who developed RP was also compared with that in those who did not. The statistical difference was determined by matched pair t test. The Radiation Therapy Oncology Group (RTOG) criteria were used for diagnosis and grading of RP.</p><p><b>RESULTS</b>With a median follow-up of 12 months, 11 (26.8%) of the 41 patients developed grade 2 and above acute RP. The mean SUV of regions (10 - 19 Gy, 20 - 29 Gy, 30 - 39 Gy, 40 - 49 Gy) increased after radiation therapy in all 41 patients. The mean SUVs after radiation therapy were 0.54, 0.68, 1.31, 1.74 and 2.27 for 0 - 9 Gy, 10 - 19 Gy, 20 - 29 Gy, 30 - 39 Gy and 40 - 49 Gy, respectively. Before the radiation therapy, the mean SUV in each region was 0.53, 0.52, 0.52, 0.53 and 0.54, respectively. These patients had significantly higher FDG activities in regions receiving 10 Gy or more (P < 0.001). Compared with their counterparts, the elevation of SUV was significantly greater in those patients who developed acute RP subsequently.</p><p><b>CONCLUSION</b>The mean SUV of the lung tissue may be a useful predictor for the acute RP. FDG-PET/CT may play a new role in the study of the radiation damage of the lung.</p>


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Fluorodeoxyglucose F18 , Positron-Emission Tomography , Methods , Radiation Pneumonitis , Diagnosis , Tomography, X-Ray Computed , Methods
16.
Chinese Journal of Radiological Medicine and Protection ; (12): 401-404, 2009.
Article in Chinese | WPRIM | ID: wpr-393482

ABSTRACT

Objective To compare the dosimetric difference in forward intensity modulation radiotherapy (fIMRT)and inverse IMRT(iIMRT)planning for breast cancer.Methods Six patients received radiotherapy alone after left breast-conserving surgery were selected.For each patient,two treatment phns(flMRT and iIMRT)were designed with Pinnacle3 7.4f.In each plan,the volume of PIT received prescription dose was not less than 95 %.The dosimetrie parameters were assessed with dose volume histograms in planning target volume (PIT)and organ of around risk(OAR).Results Of flMRT and ilMRT plans,the PTV average canformal indexwere(0.67±0.06)and(0.66±0.06)(t = 2.423,P > 0.05),average homogeneity index were (28.2±6.0)% and(26.1±6.8)%(t = 2.164,P > 0.05);the volume of left lung received 20 Gy(V20)were(18.7±3.3)% and(17.0±2.8)%(t =5.087,P<0.05),and V30 of left lung were(15.5±3.0)%and(14.0±2.6)%(t =7.272,P<0.05);V30 of heart were(4.1±3.1)% and(3.5±2.5)%(t=1.916,P > 0.05);the total monitor units were(262±5)MU and(308±14)MU(t = 7.515,P < 0.05).Conclusions There were no significant differences of CI,HI,and V30 of heart between flMRT and iIMRT.Because of fewer MUs,fIMRT plan could reduce the machine abrasion and treatment time,but V30 and V30 of left lung are higher significantly than iIMRT plan.

17.
Chinese Journal of Radiation Oncology ; (6)2005.
Article in Chinese | WPRIM | ID: wpr-562486

ABSTRACT

Objective To explore the methods, dosimetric features and short-term effects of partial breast irradiation carried out by three-dimensional external-beam irradiation (3DCPBI) assisted by active breathing control (ABC) . Methods Computed tomography (CT) simulation assisted by active breathing control (ABC) was carried out for each patient and intended to get CT images in condition of 75% deepest inspiration named moderate deep inspiration breath hold (mDIBH). The extent labeled by the silver slips located in the cavity was delineated as gross target volume (GTV) , GTV plus the margin of 15 mm was defined as planning target volume (PTV). 6 MV X-ray was selected as the radiation source and noncoplanar radiation with four three-dimensional conformal fields was used, the described dose was 34 Gy /10f/5d. The volume of GTV, PTV, the affected whole breast, and the percentage of PTV accounted for the affected whole breast , the percentages of PTV included by 100% , 95% and 90% isodose curve, the percentage of volume of the affected breast irradiated by 34. 0, 27. 2, 20. 4, 13. 6 and 6. 8 Gy , and Dmean,D5,V20 of the lungs and heart were calculated respectively. Acute radiation skin response was recorded and the cosmetic effect of the breast after radiotherapy were appraised, with the local tumor control and survival rate followed. Results The mean of volume ratio of PTV and affected whole breast was 14. 88% ; the mean of the volume covered by 90% isodose curve accounted for 92. 54% of the PTV; the volume irradiated by 34 Gy (100% of described dose) accounted for 17. 23% (mean) of the whole breast and 6. 8 Gy (20% of described dose) for 46. 11% , in other words, the volume covered by 20% of described dose was less than 50% of the whole breast. The Dmean, D5, V20 for the affected lateral lung were 1.97, 9. 25 Gy and 1. 58% , it was 0.20, 0. 87 Gy , and 0% for the unaffected lateral lung. The Dmean,D5, V20 for the heart was 0.65 Gy , 2. 82 Gy , and 0. 85%. Zero grade of acute radiation skin reaction was seen in 14 patients and gradel in 3 patients and there was not equal to or more than grade 2 of skin reaction for all the patients. Cosmetic effect were appeci-ated and satisfaction defined as excellent or good appearance of the irradiated breasts for all the patients. No recurrence of local tumor for all of the patients followed for one year. Therefore, the cosmetic result of 1 yr. follow - up was 100% and no recurence was found after 1 yr. follow - up. The 1-year tumor-free survival rate were all 100%. Conclusions For selected patients with early breast cancer after breast-conservative surgery, 3DCPBI assisted by ABC is feasible, however, the selection criteria for the patients, technique protocol and dose fractionation of 3DCPBI and its influence on late cosmetic effect, local tumor control and survival need to be continuously explored and observed in the future.

SELECTION OF CITATIONS
SEARCH DETAIL