Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J. appl. oral sci ; 19(5): 462-468, Sept.-Oct. 2011. ilus, tab
Article in English | LILACS | ID: lil-600846

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the detection of enamel-dentin occlusal caries using photostimulable phosphor plates. MATERIAL AND METHODS: The ability to detect enamel-dentin occlusal caries in 607 premolars and molars from 47 patients between 10 and 18 years old, referred to the School of Dentistry of the Federal University of Bahia, Brazil, was evaluated based on clinical and radiographic examinations, using the criteria proposed in a previous study. A total of 156 bitewing digital images were obtained using Digora® (Soredex Medical Systems, Helsinki, Finland) phosphor plates. The plates were scanned and the images were captured and displayed on a computer screen. Image evaluation was done using Digora® for Windows 2.1 software, Soredex®. The radiologists were allowed to use enhancement tools to obtain better visibility during scoring of the teeth based on the radiographic criteria proposed in a previous study. Descriptive analysis and chi-squared proportion tests were done at 5 percent significance level. RESULTS: The results of clinical examination showed a higher prevalence of teeth with a straight dark line or demineralization of the occlusal fissure (score 1) and a lower prevalence of sealed teeth (score 5). In the bitewing digital images, 47 teeth presented visible radiolucency, circumscribed, in dentin under occlusal enamel (enamel-dentin caries lesions). CONCLUSIONS: Correlating the clinical and radiographic findings, it was found that in the majority of teeth diagnosed by radiographic images as having enamel-dentin caries, no caries could be detected by clinical examination.


Subject(s)
Adolescent , Child , Female , Humans , Male , Dental Caries , Phosphorus , Radiography, Dental, Digital/methods , Age Distribution , Chi-Square Distribution , Dental Enamel/pathology , Dental Enamel , Dentin/pathology , Dentin , Image Processing, Computer-Assisted/methods , Radiography, Bitewing , Reproducibility of Results , Sex Distribution , Surface Properties
2.
Dental press j. orthod. (Impr.) ; 15(5): 42-43, set.-out. 2010. tab
Article in Portuguese | LILACS | ID: lil-562896

ABSTRACT

OBJETIVO: o objetivo deste estudo reside na avaliação do produto dose-área (DAP) e das doses de entrada na pele (DEP), empregando protocolos com tamanho de voxel diferente, obtidos com o aparelho de Tomografia Computadorizada de Feixe Cônico (TCFC) i-CAT, a fim de determinar melhores parâmetros baseados nos princípios da radioproteção. MÉTODOS: para medição do DEP foi utilizada uma câmara de ionização do tipo lápis, e para o DAP foi utilizado um aparelho PTW. Quatro protocolos foram testados, a saber: (1) 40 seg., voxel de 0,2mm e 46,72mAs; (2) 40 seg., voxel de 0,25mm e 46,72mAs; (3) 20 seg., voxel de 0,3mm e 23,87mAs; (4) 20 seg., voxel de 0,4mm e 23,87mAs. A quilovoltagem permaneceu constante (120KVp). RESULTADOS: detectou-se diferença estatisticamente significativa (p<0,001) entre os quatro protocolos, para os dois métodos de avaliação da dose de radiação (DAP e DEP). Na avaliação do DAP, os protocolos 2 e 3 promoveram uma diferença estatisticamente significativa, não sendo possível detectar qual dos protocolos na avaliação da DEP proporcionou esse resultado. CONCLUSÃO: DAP e DEP apresentam-se como métodos de avaliação para doses de radiação em tomografia computadorizada de feixe cônico, sendo necessários mais estudos para elucidar tal achado. O tamanho do voxel, isoladamente, não é capaz de interferir na dose de radiação em exames de TCFC (i-CAT). A dose de radiação para exames de TCFC (i-CAT) está diretamente relacionada ao tempo de exposição e à miliamperagem.


Objectives: The aim of this study was to evaluate the dose-area product (DAP) and the entrance skin dose (ESD), using protocols with different voxel sizes, obtained with i-CAT Cone-Beam Computed Tomography (CBCT), to determine the best parameters based on radioprotection principles. METHODS: A pencil-type ionization chamber was used to measure the ESD and a PTW device was used to measure the DAP. Four protocols were tested: (1) 40s, 0.2 mm voxel and 46.72 mAs; (2) 40s, 0.25 mm voxel and 46.72 mAs; (3) 20s, 0.3 mm voxel and 23.87 mAs; (4) 20s, 0.4 mm voxel and 23.87 mAs. The kilovoltage remained constant (120kVp). RESULTS: A significant statistical difference (p<0.001) was found among the four protocols for both methods of radiation dosage evaluation (DAP and ESD). For DAP evaluation, protocols 2 and 3 presented a statistically significant difference, and it was not possible to detect which of the protocols for ESD evaluation promoted this result. CONCLUSIONS: DAP and ESD are evaluation methods for radiation dose for Cone-Beam Computed Tomography, and more studies are necessary to explain such result. The voxel size alone does not affect the radiation dose in CBCT (i-CAT) examinations. The radiation dose for CBCT (i-CAT) examinations is directly related to the exposure time and milliamperes.


Subject(s)
Cone-Beam Computed Tomography , Radiation Exposure Measurement
3.
RPG, Rev. Pós-Grad ; 17(3): 173-176, jul.-set. 2010. ilus
Article in English | LILACS, BBO | ID: biblio-855265

ABSTRACT

Forame mentual acessório: relato de caso. Variações anatômicas associadas ao forame mentual são relativamente incomuns. Dentre tais variações, a presença de um ou mais forames mentuais acessórios tem sido relatada em raros casos. O conhecimento da sua localização em relação ao forame mentual principal é de fundamental importância na avaliação prévia de procedimentos cirúrgicos e endodônticos. Neste artigo, um caso de forame mentual acessório foi apresentado através de imagens por tomografia computadorizada, e as principais complicações relacionadas a essa variação anatômica são discutidas


Subject(s)
Humans , Female , Adolescent , Anatomy, Cross-Sectional , Mandible , Tomography, Spiral Computed , Bicuspid , Mandibular Nerve , Therapeutics
4.
Rev. Ciênc. Méd. Biol. (Impr.) ; 8(1): 85-90, jan.-abr. 2009. ilus
Article in Portuguese | LILACS, BBO | ID: lil-545811

ABSTRACT

A osteoporose é uma doença sistêmica dos ossos, caracterizada pela diminuição da massa óssea e deterioração da microarquitetura do tecido ósseo, o que leva a um aumento da fragilidade óssea e da susceptibilidade à fratura. Suas manifestações, na cavidade oral, são caracterizadas por: reabsorção do processo alveolar, perda dentária, doença periodontal crônica destrutiva, dores relacionadas ao seio maxilar ou fraturas. O principal método de diagnóstico da osteoporose é a densitometria óssea, embora esse exame seja de difícil acesso para a população, em alguns países. Sendo assim, propõe-sea utilização de radiografias panorâmicas dentárias nessa avaliação, já que elas costumam ser procedimentos de rotina na clínica odontológica. Vários pesquisadores propuseram índices para avaliar as alterações osteoporóticas na cavidade oral, a partir de radiografias panorâmicas, como o Índice da Cortical Mandibular, o Índice Panorâmico Mandibular e a Técnica proposta por Wical e Swoope. Todas essas técnicas avaliam a região basal da mandíbula, posterior ao forame mentual, por ser uma área que preenche os requisitos para que ocorra uma menor variação inter e intra-indivíduos em relação à anatomia, forma, estrutura óssea e função. Dessa forma, os dentistas, em geral, poderiam fazer um correto encaminhamento dos pacientes para um tratamento específico, além de ter acesso à qualidade óssea do paciente, que é de grande importância no planejamento de implantes dentários.


Subject(s)
Mandible , Osteoporosis , Radiography, Panoramic
5.
Rev. Ciênc. Méd. Biol. (Impr.) ; 6(2): 145-151, maio-ago. 2007. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-529664

ABSTRACT

A avaliação radiográfica da osteointegração emprega a redução do nível de perda óssea marginal como modalidade diagnóstica reconhecida na literatura, mesmo com suas limitações. Novos testes de diagnóstico radiográfico, além de fornecerem as informações contidas nas imagens convencionais, devem permitir avaliar a qualidade e as mudanças de densidade óssea alveolar como o permite a imagem digital. Este trabalho teve como objetivo analisar radiografias periapicais pré-implante, pós-implante até 30 dias, até 60 dias e até 120 dias, digitalizadas pelo sistema DentScan DentView, através dos valores de tons de cinza das regiões adjacentes ao implante dentário, representadas pelo osso alveolar mesial, distal, apical e implante-envolvente, ao longo do período de cicatrização. Foram escaneadas pelo sistema radiografias periapicais de arquivo de sete indivíduos que receberam implantes unitários de superfície tratada. Após a leitura dos valores de tons de cinza das áreas adjacentes ao implante, os resultados apresentaram um aumento substancial em todos os sítios pós-implante no período de 30 dias. Na maioria dos sítios, ocorre uma queda desses valores no período de 60 dias e um aumento no período de 120 dias. A mensuração dos tons de cinza afigura-se boa ferramenta para o acompanhamento radiográfico durante período de cicatrização das regiões adjacentes ao implante dentário. Novos estudos, com ampliação da amostra e do período de acompanhamento, devem ser realizados para inferir padrões de osteointegração em implantes dentários.


Subject(s)
Dental Implants , Osseointegration , Radiography, Dental, Digital
SELECTION OF CITATIONS
SEARCH DETAIL