Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Intestinal Research ; : 328-337, 2017.
Article in English | WPRIM | ID: wpr-117803

ABSTRACT

BACKGROUND/AIMS: Recent genome-wide analyses have provided strong evidence concerning adverse events caused by thiopurine drugs such as azathioprine (AZA) and 6-mercaptopurine. The strong associations identified between NUDT15 p.Arg139Cys and thiopurine-induced leukopenia and severe hair loss have been studied and confirmed over the last 2 years. However, other coding variants, including NUDT15 p.Val18_Val19insGlyVal, NUDT15 p.Val18Ile, and FTO p.Ala134Thr, and a noncoding variation in RUNX1 (rs2834826) remain to be examined in detail in this respect. Therefore, we investigated the correlation between these adverse events and the 5 recently identified variants mentioned above among Japanese patients with inflammatory bowel diseases (IBD). METHODS: One hundred sixty thiopurine-treated patients with IBD were enrolled. Genotyping was performed using TaqMan SNP Genotyping Assays or Sanger sequencing. RESULTS: None of the 5 variants were associated with gastrointestinal intolerance to AZA. However, NUDT15 p.Arg139Cys was significantly associated with the interval between initiation and discontinuation of AZA among patients with gastrointestinal intolerance. This variant was strongly associated with early (<8 weeks) and late (≥8 weeks) leukopenia and severe hair loss. Moreover, it correlated with the interval between initiation of thiopurine therapy and leukopenia occurrence, and average thiopurine dose. NUDT15 p.Val18_Val19insGlyVal, NUDT15 p.Val18Ile, FTO p.Ala134Thr, and RUNX1 rs2834826 exhibited no significant relationship with the adverse events examined. CONCLUSIONS: Of the 5 variants investigated, NUDT15 p.Arg139Cys had the strongest impact on thiopurine-induced leukopenia and severe hair loss; therefore, its genotyping should be prioritized over that of other variants in efforts to predict these adverse events in Japanese patients with IBD.


Subject(s)
Humans , Mercaptopurine , Asian People , Azathioprine , Clinical Coding , Hair , Inflammatory Bowel Diseases , Leukopenia
2.
Diabetes & Metabolism Journal ; : 265-274, 2017.
Article in English | WPRIM | ID: wpr-174852

ABSTRACT

BACKGROUND: Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference. METHODS: Thirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard. RESULTS: A significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76) and nighttime (r=0.82). The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg·hr/dL with 88.2% sensitivity and 81.5% specificity. CONCLUSION: We showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day.


Subject(s)
Humans , Area Under Curve , Blood Glucose , Diabetes Mellitus , Extracellular Fluid , Glucose , Hydrogels , Hyperglycemia , Inpatients , Mass Screening , Plastics , Sensitivity and Specificity , Sodium
3.
Diabetes & Metabolism Journal ; : 326-333, 2016.
Article in English | WPRIM | ID: wpr-108204

ABSTRACT

BACKGROUND: Management of postprandial hyperglycemia is a key aspect in diabetes treatment. We developed a novel system to measure glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET) for simple monitoring of postprandial glucose excursions. In this study, we evaluated the relationship between our system and continuous glucose monitoring (CGM) by comparing glucose AUC obtained using MIET with that obtained using CGM for a long duration. METHODS: Twenty diabetic inpatients wearing a CGM system were enrolled. For MIET measurement, a plastic microneedle array was applied to the skin as pretreatment, and hydrogels were placed on the pretreated area to collect interstitial fluid. Hydrogels were replaced every 2 or 4 hours and AUC was predicted on the basis of glucose and sodium ion levels. RESULTS: AUC predicted by MIET correlated well with that measured by CGM (r=0.93). Good performances of both consecutive 2- and 4-hour measurements were observed (measurement error: 11.7%±10.2% for 2 hours and 11.1%±7.9% for 4 hours), indicating the possibility of repetitive measurements up to 8 hours. The influence of neither glucose fluctuation nor average glucose level over the measurement accuracy was observed through 8 hours. CONCLUSION: Our system showed good relationship with AUC values from CGM up to 8 hours, indicating that single pretreatment can cover a large portion of glucose excursion in a day. These results indicated possibility of our system to contribute to convenient monitoring of glucose excursions for a long duration.


Subject(s)
Humans , Area Under Curve , Extracellular Fluid , Glucose , Hydrogels , Hydrogels , Hyperglycemia , Inpatients , Plastics , Skin , Sodium
SELECTION OF CITATIONS
SEARCH DETAIL