Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
The Korean Journal of Hepatology ; : 275-283, 2005.
Article in Korean | WPRIM | ID: wpr-75925

ABSTRACT

BACKGROUND/AIMS: Patients with hepatocellular carcinoma (HCC) may manifest paraneoplastic syndromes such as hypercholesterolemia, hypoglycemia, hypercalcemia and erythrocytosis. This study was aimed at evaluating the incidence and clinical significance of paraneoplastic syndromes in Korean HCC patients. METHODS: The medical records of 165 HCC patients who were diagnosed and died in the Kyung Hee University Hospital, were reviewed retrospectively. The following variables were analyzed: age, gender, hepatitis markers, platelet, liver function test, alpha-fetoprotein (AFP), Child-Pugh score, tumor features, and the duration of their survival. RESULTS: In total, paraneoplastic syndromes were presented in 43.6% of the HCC patients during the course of their disease. Hypercholesterolemia was solely presented in 14.5%, hypoglycemia in 12.7% and hypercalcemia in 7.8%. The patients who presented with more than 2 syndromes were 8.5%. While 80% of erythrocytosis (4/5) and 51.6% of hypercholesterolemia (16/31) was presented at the time of HCC diagnosis, hypoglycemia and hypercalcemia mainly occurred as terminal events. The patients with paraneoplastic syndromes were younger and had higher rates of portal vein thrombosis, bi-lobar tumor involvement and tumor more of more than 10 cm in diameter, compared to those patients without them. The proportion of patients with a serum AFP more than 400 ng/mL tended to be higher in the patients with paraneoplastic syndromes. The HCC patients with paraneoplastic syndromes, except for erythrocytosis, had a shorter survival than those patients without them. CONCLUSIONS: Paraneoplastic syndromes are not infrequently presented in HCC patients, especially at an advanced stage, and the survival of these patients is relatively shorter.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Carcinoma, Hepatocellular/complications , English Abstract , Liver Neoplasms/complications , Paraneoplastic Syndromes/complications
2.
Tuberculosis and Respiratory Diseases ; : 838-845, 1995.
Article in Korean | WPRIM | ID: wpr-167380

ABSTRACT

The determination of ADA(adenosine deaminase) activity in pleural fluid is useful in differental diagnosis of pleural effusion. The conventional method of determining ADA activity used by Giusti was influenced by contamination of ammonia. Additionally, because Giusti's method was mannual method a determining the ADA activities in sample, was not easily automated. In 1993, Oosthuizen HM with collegues developed simple kinetic method for determining ADA activity. It was reliable and suiable method for automation. In this study, we have measured ADA activity in 162 patients with various pleural effusion by Hitachi 747 autoanalyser using the Oosthuizen kinetic method for the purpuse of determination of new diagnostic cut-off value for the tuberculous effusion and evaluation of the correlation between the conventional method and new automated method. This new method of an enzymatic reaction involves 2, 6-dichlorophenolindophenol dye(DICP), adenosine, xanthine oxidase(XO), and nucleoside phosphorylase(NP). The results were as follows: 1) The mean pleural ADA activity of the tuberculous effusion was 52.53 +/-16.43 U/L and significantly higher than that of other groups(p<0.001). If the diagnostic cut-off value of pleural ADA activity for tuberculous effusion is above 30 U/L, the sensitivity is 96% and the specificity is 90%. 2) The mean pleural to serum ADA activity ratio of the tuberculous effusion was 2.29+/-0.96 and it was also significantly higher than that of other pleural groups(p<0.001). If the diagnostic cut-off value of pleural to serum ADA activity ratio is 1.5, the sensitivity is 80% and the specificity is 88% in the diagnosis of tuberculous pleural effusion. 3) The new kinetic method is correlates well to Giuisti's conventional method(r=0.971). In conclusion, the new kinetic method described is easily automated and seems to be suitable for the routine determination of ADA activity.


Subject(s)
Humans , Adenosine , Adenosine Deaminase , Ammonia , Automation , Diagnosis , Pleural Effusion , Sensitivity and Specificity , Xanthine
SELECTION OF CITATIONS
SEARCH DETAIL