Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Rev. gastroenterol. Perú ; 43(4)oct. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1536364

ABSTRACT

La endoscopía digestiva ha evolucionado de una técnica puramente diagnóstica a un procedimiento terapéutico. Esto es posible en muchos casos gracias al uso de fluoroscopía, lo cual conlleva la exposición a radiaciones ionizantes tanto de los pacientes como del personal actuante. La colangiopancreatografía retrógrada endoscópica (CPRE), que requiere necesariamente de fluoroscopia, es catalogada por la Food and Drug Administration como un examen con potencial riesgo de desencadenar lesiones inducidas por radiación. El presente artículo de revisión repasa los efectos biológicos de las radiaciones, los tipos de equipos radiológicos utilizados en CPRE, así como las magnitudes y unidades dosimétricas, para finalmente abordar los elementos de radio protección en la sala de endoscopia. El objetivo es brindar al lector la informacion para poder realizar estos procedimientos con la mayor seguridad radiológica tanto para los pacientes como para el personal ocupacionalmente expuesto.


Endoscopy has evolved from a purely diagnostic technique to a therapeutic procedure. This is possible in many cases thanks to the use of fluoroscopy, which entails exposure to ionizing radiation for both patients and the personnel involved. Endoscopic retrograde cholangiopancreatography (ERCP), which necessarily requires fluoroscopy, is classified by the Food and Drug Administration as an examination with a potential risk of triggering radiation induced injuries. This article reviews the biological effects of radiation, the types of radiological equipment used in ERCP, as well as the magnitudes and dosimetric units, to finally address the radio protection elements in the endoscopy room. The objective is to provide the reader with the information to be able to perform these procedures with the greatest radiological safety for both patients and occupationally exposed personnel.

2.
Rev. chil. cardiol ; 41(1): 28-33, abr. 2022.
Article in Spanish | LILACS | ID: biblio-1388110

ABSTRACT

RESUMEN: En el año 2013, se publicó un artículo acerca de lo realizado en Chile en temas de protección radiológica en cardiología intervencionista (CI) pediátrica. A continuación se muestra el trabajo de continuidad realizado en los últimos 8 años, destacando los principales resultados alcanzados y proponiendo mejoras en la seguridad y protección radiológica en esta práctica clínica. Desde el año 2013 se han seguido evaluando en términos de dosis de radiación y calidad de imagen, los sistemas de rayos X utilizados en Chile para procedimientos de CI pediátricos y, en particular, los equipos de los servicios de los Hospitales Luis Calvo Mackenna y Roberto del Rio. Se han medido las tasas de dosis de radiación dispersa a la posición habitual de los ojos y tobillos de los cardiólogos que operan los equipos de rayos X. También contamos con un conjunto de "Niveles de Referencia para Diagnóstico" clasificados por rangos de edad y peso, junto con la estimación de valores de dosis por órgano y dosis efectiva para los pacientes. Podemos afirmar que, actualmente, contamos con una metodología consolidada para caracterizar, en términos de dosis y calidad de imagen, los sistemas de rayos X. Sin embargo, sigue pendiente actualizar la normativa nacional que regula el uso seguro de las radiaciones ionizantes en medicina, como también aspectos de formación en protección radiológica para el personal médico implicado.


ABSRSCT: An article on the status of radiological protection during procedures of interventional cardiology in pediatric patients in Chile was published in 2013. The present article relates the continuing efforts to improve radiological protection highlighting their results and proposing additional measures to improve radiological protection during the procedure. Since 2013 we have continued the evaluation of radiation doses, image quality, and X Ray systems used in Chile. We have measured diffused radiation dose at operator´s eye and ankle levels to elaborate a "Reference guide" according to patient´s age and weight. However, we still lack a national regulatory norm for the X Ray systems to be used and for the appropriate training of those involved in procedures of interventional cardiology in pediatric patients.


Subject(s)
Humans , Pediatrics , Radiation Protection/methods , Security Measures/trends , Chile , Dosimetry
3.
J. health med. sci. (Print) ; 7(4): 215-221, oct.-dic. 2021.
Article in Spanish | LILACS | ID: biblio-1396092

ABSTRACT

El objetivo del presente artículo ha sido describir el programa "Optimización de la Protección en Radiología Intervencionista Pediátrica en América Latina y el Caribe" (OPRIPALC) que nace el año 2018 como respuesta conjunta de la Organización Panamericana de la Salud y la Organización Mundial de la Salud, en cooperación con el Organismo Internacional de Energía Atómica, para colaborar con sus Estados miembros en asegurar que las exposiciones a la radiación de los pacientes pediátricos sean las mínimas necesarias durante los procedimientos intervencionistas. Actualmente, hay 18 centros de los siguientes 10 países que participan: Argentina, Brasil, Chile, Colombia, Costa Rica, Cuba, Ecuador, México, Perú y Uruguay. Para el desarrollo del programa se plantean una serie de objetivos, productos, actividades y resultados esperados. La puesta en marcha de la WEB de OPRIPALC ha significado un instrumento muy válido para seguir la información actualizada del programa. Un programa actualizado de formación en radioprotección para los profesionales implicados en el programa, se está realizando por medio de "webinars". Se deberá seguir actuando en la aplicación del programa de control de calidad básico para los equipos de rayos X participantes y validar los valores de los Niveles de Referencia para Diagnóstico (NRDs). Se propone formar un equipo de trabajo entre los Físicos Médicos y Tecnólogos Médicos participantes de OPRIPALC para implicarse en las pruebas de control básicas que todos los centros debieran realizar. Se han presentado algunos resultados iniciales de OPRIPALC en eventos científicos internacionales. Se está avanzando en proponer unos primeros valores sobre NRDs en procedimientos de intervencionismo cardiológico pediátrico por bandas de edad y peso. OPRIPALC es una de las pocas iniciativas de carácter regional para obtener valores de NRDs en procedimientos intervencionistas pediátricos. Se espera que tanto los valores de referencia como la metodología empleada en OPRIPALC, puedan ser utilizados en otras regiones del mundo.


The objective of this article has been to describe the program "Optimization of Protection in Pediatric Interventional Radiology in Latin America and the Caribbean" (OPRIPALC) that was born in 2018 as a joint response of the Pan American Health Organization and the World Organization of the Health, in cooperation with the International Atomic Energy Agency, to collaborate with its member states in ensuring that radiation exposures of pediatric patients are the minimum necessary during interventional procedures. Currently, there are 18 centers from the following 10 countries participating: Argentina, Brazil, Chile, Colombia, Costa Rica, Cuba, Ecuador, Mexico, Peru and Uruguay. For the development of the program, a series of objectives, products, activities and expected results are proposed. The launch of the OPRIPALC WEBSITE has been a very valid instrument for following up-to-date information on the program. An updated training program in radiation protection for the professionals involved in the program is being carried out through webinars. It should continue acting in the application of the basic quality control program for the participating X-ray equipment and validate the values of the Diagnostic Reference Levels (DRLs). It is proposed to form a work team among the OPRIPALC participating medical physicists to get involved in the basic control tests that all centers should carry out. Some initial results of OPRIPALC have been presented at international scientific events. Progress is being made in proposing first values on DRLs in pediatric cardiac intervention procedures by age and weight bands. OPRIPALC is one of the few regional initiatives to obtain DRLs values in pediatric interventional procedures. It is expected that both the reference values and the methodology used in OPRIPALC can be used in other regions of the world.


Subject(s)
Humans , Child , Pediatrics/standards , Radiation Protection/standards , Cardiology/standards , Quality Control , Reference Standards , Reference Values , Safety , Radiology, Interventional , Caribbean Region , Diagnostic Techniques, Cardiovascular , Process Optimization , Diagnostic Reference Levels , Latin America
4.
Rev. urug. cardiol ; 30(2): 131-138, ago. 2015. ilus, graf, tab
Article in Spanish | LILACS-Express | LILACS | ID: lil-760512

ABSTRACT

Se ha descrito que la protección pélvica plomada aplicada al paciente (4P) reduce la dosis de radiación recibida por el primer operador (PO) en angiografía coronaria (AC) tanto por acceso radial derecho (ARD) como femoral derecho. Objetivo: el objetivo principal de este estudio fue evaluar el efecto del uso de 4P sobre la radiación recibida por el PO en procedimientos de AC con o sin angioplastia (ATC) por ARD. Los objetivos secundarios son: comparación de las dosis del primer operador recibidas en AC y ATC con valores estándar internacionales y correlación entre la dosis emitida por el angiógrafo y la dosis recibida por el PO en los grupos con y sin 4P. Método: se realizó un estudio randomizado, prospectivo, sobre pacientes sometidos a AC con o sin ATC, asignados en forma aleatoria a una falda plomada envolvente de 0,5 mm colocada entre la cintura y las rodillas del paciente. Los operadores utilizaron en todos los casos falda, chaleco y protector cervical equivalente a 0,5 mm de plomo, lentes plomados, mampara colgante y cortina plomada bajo mesada. La dosimetría del PO (DPO) fue realizada con un detector DMC 3000 (rango de energía: 15 KeV-7 MeV, rango de medida: 1 mSv-10 Sv), ubicado por fuera y sobre el lado izquierdo del collar de protección cervical del PO. Se registraron variables epidemiológicas y dosis del procedimiento, incluyendo DPO en mSv, producto KERMA (Kinetic Energy Released in a Material) área (PK A) en mGym², radiación total (RT) en mGy, tiempo de fluoroscopía (TF) en minutos y número de escenas (NE). Se utilizó test de Student para comparación de variables continuas, con un valor a=0,05. Resultados: se incluyó un total de 100 pacientes. El promedio de edad fue de 64 años y el 39% eran mujeres; 56 pacientes recibieron solo AC y los restantes 44 recibieron ATC adicional. Los valores promedio de TF, NE y la DPO para AC y ATC fueron: 6,9/16,6 minutos, 10/21 escenas y 24/33 mSv, respectivamente, y su comparación con los valores estándar internacionales no mostró diferencias estadísticamente significativas. Se definieron dos grupos de acuerdo a la randomización, 47 pacientes en el grupo con protección pélvica (grupo 4P) y 53 en el grupo sin la misma (grupo no 4P). Las características basales así como el número de ATC y sus particularidades fueron similares en ambos grupos. Los resultados relacionados con la radiación para el grupo 4P vs no 4P fueron los siguientes: PK A (mGym²) 8374,5 ± 1006 vs 8959,1 p=0,705; DPO (mSv) 40,4 ± 5,9 vs 36,7 ± 5,4 p=0,642; RT (mGy) 1545,3 ± 190,9 vs 1649,6 ± 219,8, p=0,724; TF (minutos) 11,6 ± 1,4 vs 10,7 ± 1,4, p=0,654; NE 14 vs 11, p=0,981. Conclusión: en este escenario del mundo real, el uso de 4P no se asoció con una disminución de la DPO en procedimientos de AC con o sin ATC ni con un cambio en la relación PK A-DPO en procedimientos de AC o ATC por ARD, realizados por operadores con valores promedio de radiación aceptables internacionalmente.


It has been reported that lead pelvic protection applied to the patient reduces radiation dose received by the first operator (PO) during coronary angiography (CA) by radial and femoral access. Objective: the main objective is to evaluate the effect of using pelvic leaded protection (4P) on the radiation received by the first operator (PO) in CA procedures with or without PTCA and/or percutaneous transluminal coronary angioplasty (PTCA) by right radial approach. Secondary objectives are: comparison of dose of the PO in CA and PTCA with international standard values and correlation between emitted doses by angiograph and received doses in patients with and without 4P. Method: we performed a prospective and randomized trial about patients who underwent CA with or without PTCA. Patients were randomly assigned to the use of pelvic protection, consisting of a 0,5 mm lead equivalent skirt, placed between the waist and the knees. In all cases th ePO used a lead equivalent skirt, vest and cervical collar as well as leaded glasses, hanging screen and a lead curtain under the patient table. First operator dosimetry (FOD) was measured with a DMC detector 3.000 (energy range: 15 KeV-7 MeV, measuring range: 1 mSv -10 SV) located on the outer left side of the cervical collar. Results: a total of 100 patients (P) were included. The average age was 64 years and 39% were women. 56 P received only CA and the remaining 44 received additional PTCA. The average values of fluoroscopy time (FT), scenes number (SN) and FOD for CA and PTCA were: 6,9/16,6 minutes, 10/21 scenes and 24/33 Sv respectively and compared with international standards values showed no statistically significant differences. Two groups according to randomization were defined, 47 P in the group with pelvic protection (4P group) and 53 in the group without it (no 4P group). Baseline characteristics as well as the number of PTCA and their characteristics were similar between groups. The radiation related results for the 4P group vs no 4P group were the following: KERMA-area product (mGym²) 8374,5 ±1006 vs 8959,1, p=0,705, FOD (mSv) 40,4±5,9 vs 36,7±5,4, p=0,642, total radiation (mGy) 1545,3±190,9 vs 1649,6±219,8, p=0,724, FT (minutes) 11,6±1,4 vs 10,7±1,4, p=0,654, SN 14 vs 11, p=0,981. Conclusion: in this “real world” scenario, the use of pelvic protection was not associated with a decrease in radiation dose to the first operator or with a change in the PDA-DPO ratio during CA and PTCA performed by right radial approach and by operators with standard radiation parameters.

5.
Rev. bras. cardiol. invasiva ; 22(1): 87-98, Jan-Mar/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-712743

ABSTRACT

Discutimos aqui aspectos vinculados ao enquadramento legal, a recomendações internacionais e a programas de formação em proteção radiológica; ao angiógrafo e à qualidade da imagem; aos efeitos biológicos e aos riscos das radiações ionizantes; às lesões em operadores e pacientes; aos níveis de referência do paciente; ao limite de dose ocupacional e a suas medidas de prevenção. O uso das radiações ionizantes acarreta riscos, que, contudo, justificam-se em procedimentos diagnósticos e terapêuticos. A consciência e o conhecimento desses riscos minimizam o dano, otimizando a qualidade da imagens e o uso seguro das radiações ionizantes. Tem-se demonstrado a ocorrência de cataratas radioinduzidas em trabalhadores de laboratórios de cateterismo. Diversos estudos sugerem que pode haver um risco significativo de opacidade do cristalino, caso não se utilizem adequadamente os dispositivos de proteção radiológica. Adicionalmente, esses tipos de procedimentos intervencionistas são realizados na América Latina, geralmente por médicos especialistas, com a colaboração de enfermeiros, tecnólogos e técnicos, que, muitas vezes, não têm formação adequada em proteção radiológica.


We discuss some aspects related to the legal framework, international recommendations and training programs on radiological protection; image quality and equipment; the biological effects and risks of ionizing radiation; lesions in patients and operators; patient's reference levels; occupational dose limit and preventive actions. The use of ionizing radiation involves risks that are justified in diagnostic and therapeutic procedures. The awareness and knowledge of these risks minimizes the damage, optimizing the quality of images and safe use of ionizing radiation. There is evidence of radiation-induced cataracts in individuals who work in catheterization laboratories. Several studies suggest there may be a significant risk of lens opacity, if radiological protection devices are not properly used. Additionally, these interventional procedures are performed in Latin America, usually by medical specialists in collaboration with nurses, technologists and technicians, who often do not have adequate training in radiological protection.


Subject(s)
Humans , Diagnostic Imaging/adverse effects , Diagnostic Imaging , Radiation Protection/standards , Radiation, Ionizing , Radiation Injuries/complications , Radiation Risks , Diagnostic Techniques and Procedures/adverse effects
6.
Rev. chil. cardiol ; 33(1): 44-50, 2014. tab
Article in Spanish | LILACS | ID: lil-713526

ABSTRACT

El objetivo de este articulo fue entregar una guia con recomendaciones para mejorar la Seguridad Radiológica durante los procedimientos de intervencionismo cardiológico. Se describe la clasificación de los efectos causados por las radiaciones ionizantes a los pacientes y personal médico. Se recomienda la aplicación de un programa de Garatia de Calidad, el cual implicará tantos gastos, como mayores beneficios. Como parte de este programa, se sugiere la implementación de un programa de Protección Radiológica, que incluya al personal, monitoreo de la radiación, blindajes y entrenamiento del personal. Se deben establecer acciones permanentes en cada laboratorio de hemodinamia para gestionar de la mejor forma posible las dosis de radiación antes, durante y después de la intervención. Finalmente, para avanzar en la implementación de estas recomendaciones, creemos que un paso fundamental es la revisión de nuestro marco juridico en el ámbito de la Seguridad Radiológica, donde resultan imprescindibles aspectos como la implementación de programas de Garantia de Calidad y Protección Radiológica, junto al establecimiento de Niveles Referenciales de dosis para pacientes.


In this paper we present guidelines aimed to improve radiation safety during invasive cardiovascular procedures. Unwanted effects upon patients and medical personnel are conventionally classified. A program of Quality Assurance is proposed, an aspect of which is a program for radiologic protection, including operator protection, radiation monitoring, shielding and personnel training. Permanent and specific actions should be taken at every cardiovascular lab, before, during and after interventions. In order to implement these guidelines and actions, a fundamental step is a review of current legislation. Specific programs for quality control and radiologic protection along with a definition of acceptable radiation exposure doses are required.


Subject(s)
Humans , Cardiology/methods , Radiation Protection/standards , Radiography, Interventional/adverse effects , Radiation Injuries/prevention & control , Quality Control , Radiation Exposure , Radiation Injuries/etiology
7.
Rev. chil. cardiol ; 32(3): 223-229, 2013. ilus, tab
Article in Spanish | LILACS | ID: lil-705226

ABSTRACT

El objetivo de este artículo es mostrar los principales resultados alcanzados en Chile durante los últimos 5 años en procedimientos de cardiología intervencionista (CI) pediátrica y discutir acciones futuras para mejorar la seguridad radiológica en esta práctica médica. Todos los sistemas de rayos X usados en procedimientos de CI pediátrica en Chile han sido caracterizados en términos de dosis y calidad de imagen. En conjunto con esto, se han medido las tasas de dosis de radiación dispersa a la posición de los ojos y tobillos de los médicos cardiólogos. En mayo de 2010, se celebró en Santiago de Chile, un taller organizado por la Agencia Internacional de Energía Atómica (IAEA) que fue el punto de partida para un programa piloto sobre dosimetría de pacientes y personal médico para América Latina y el Caribe, con participantes de 11 países. En forma paralela, se realizó un curso piloto de formación en Protección Radiológica. Los primeros valores de dosis a pacientes pediátricos reportados en el marco del programa piloto realizado por la IAEA en América Latina y el Caribe, incluyó 70 procedimientos de Chile que posteriormente, fueron ampliados a una muestra de 544 procedimientos. Para mantener y mejorar las prácticas aprendidas, pensamos que el primer y fundamental paso que se podría dar en Chile, sería revisar y actualizar la legislación que regula el uso de radiaciones ionizantes, donde se incorpore la implementación de programas de Garantía de Calidad y una formación en Protección Radiológica diferenciada de acuerdo a las necesidades del personal médico.


Further actions to improve radiation safety in this medical practice are discussed. All the X-ray systems used in paediatric IC procedures in Chile have been characterized in terms of dose and image quality. In addition, dose rates of scattered radiation to the position of the eyes and ankles of cardiologists have been measured. In May 2010, in Santiago , Chile, a workshop organized by the International Atomic Energy Agency (IAEA) was the starting point for a pilot program on patient dosimetry and medical personnel for Latin America and the Caribbean, with participants from 11 countries. A pilot training course on Radiological Protection was given as part of the program. The first dose values reported for paediatric patients under the pilot program conducted by the IAEA in Latin America and the Caribbean included 70 procedures in Chile later extending to a total of 544 procedures. We think that a fundamental first step to improve IC radiation safety in Chile, would be to revise and update legislation on the use of ionizing radiation, including the implementation of quality assurance programs and training in radiation rrotection according to those involved in IC procedures.


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Child , Adolescent , Cardiology , Guidelines for Radiological Safety , Pediatrics , Radiation Protection/standards , Chile , Radiation Dosage , Professional Competence
8.
Rev. chil. cardiol ; 21(1): 45-52, ene.-mar. 2002. ilus
Article in Spanish | LILACS | ID: lil-340356

ABSTRACT

Se describen los aspectos básicos relacionados con la protección radiológica de los especialistas médicos y del personal auxiliar en las instalaciones de cardiología intervencionista. La protección radiológica del paciente se plantea como un compromiso entre la información necesaria que depende de la calidad de las imágenes y las dosis de radiación que se deben impartir para obtener dicha información. Se citan las recomendaciones internacionles más relevantes y las acciones programadas de investigación que se están desarrollando para mejorar el nivel de protección y calidad en las instalaciones de cardiología. Se describe la influencia de las características de los equipos de rayos X y de las salas en las que están instalados, la complejidad de los procedimientos, la formación en protección radiológica de los diferentes grupos profesionales y la disponibilidad de elementos de protección. En algunos casos, la falta de programas de control de calidad adecuados ha contribuido a que se produzcan lesiones graves en la piel de los pacientes. Se discuten los procedimientos para reducir los riesgos de los especialistas y de los pacientes sin comprometer la calidad de los procedimientos destacando que al proteger al paciente se mejora también el nivel de protección de los especialistas médicos. Estos procedimientos se deben incorporar a los programas de garantía de calidad, incluyendo los aspectos de formación en protección radiológica, revisión de los dispositivos de protección, dosimetría personal, medidas de dosis a los pacientes y evaluación de la calidad de imagen, control de calidad de equipos de rayos X e introducción de medidas correctoras cuando proceda y su seguimiento. Se debe prestar especial atención a la detección y seguimiento de los casos de posibles dosis altas en piel


Subject(s)
Humans , Cardiovascular Surgical Procedures/methods , Radiation Protection/methods , Radiology, Interventional/methods , Diagnostic Techniques, Cardiovascular/standards , Radiation Dosage , Cardiovascular Surgical Procedures/adverse effects , Quality Control , Radiation Exposure , Radiation Exposure Measurement , Radiology, Interventional/standards , Radiology, Interventional , Radiometry , Skin , Diagnostic Techniques, Cardiovascular/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL