Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Rev. Fac. Med. (Bogotá) ; 66(2): 179-185, abr.-jun. 2018. tab, graf
Article in English | LILACS | ID: biblio-956835

ABSTRACT

Abstract Introduction: Spirometry in workers exposed to air pollutants allows for early identification of lung function impairment. Reference values (RV) for spirometric variables (SV) obtained in Cuban workers (CW) are not available. Objective: To obtain adequate SV-specific RV adequate for supposedly healthy CW. Materials and methods: Retrospective, analytical study. Forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), FEV1/FVC ratio and 25-75% forced expiration fraction for FVC (FEF25 75) values were observed in 1 088 allegedly healthy, non-smoker workers from both sexes, aged between 20 - 65 years, assisted at the Instituto Nacional de la Salud de los Trabajadores (INSAT) in Havana (Cuba) between 2009 and 2015. RV were obtained for each sex as solutions of the regression function (RF) Υ=α+β x age+χ x height+ε (Y: FVC, FSV1, FEV1/FVC, FEF25-75). Results: Advanced ages were associated with lower FVC and FEV1. Taller individuals showed higher FVC and FEV1. A RF including age and height implied a higher coefficient of determination r2 and lower estimation of ε error. Behavior of SV values predicted with the locally developed equation was less biased than those obtained with other foreign equations. Conclusions: Locally developed RV may be more effective for diagnosing lung diseases in CW.


Resumen Introducción. La espirometría permite identificar de forma precoz el deterioro pulmonar en trabajadores expuestos a contaminantes laborales. No se tienen valores de referencia (VR) para variables espirométricas (VE) en trabajadores cubanos (TC). Objetivo. Obtener VR para VE en TC supuestamente sanos. Materiales y métodos. Estudio retrospectivo-analítico. Se obtuvo la capacidad vital forzada (CVF), el volumen espiratorio forzado en el primer segundo (VEF1), el cociente VEF1/CVF y la fracción de la espiración forzada al 25-75% de la CVF (FEF25-75) de 1 086 TC supuestamente sanos, no fumadores, de ambos sexos, con edades entre 20 y 65 años y atendidos en el Instituto Nacional de la Salud de los Trabajadores de La Habana, Cuba, entre 2009 y 2015. Los VR se obtuvieron para cada sexo de las funciones de regresión Υ=α+β x Edad+χ x Talla+ε (Y=CVF, VEF1, VEF/CVF, FEF25-75). Resultados. Edades avanzadas se asociaron con CVF y VEF1 disminuidos; la talla elevada se asoció con mayores CVF y VEF1; una FR construida se asoció con la edad, y la talla implicó un coeficiente r2 de determinación superior y un error menor. El comportamiento de la VE predicho con la ecuación desarrollada fue menos sesgado que el observado con otras importadas. Conclusiones. Los VR construidos localmente pueden ser más efectivos en el diagnóstico de las afecciones pulmonares de los TC.

2.
Article in Spanish | LILACS, CUMED | ID: lil-411991

ABSTRACT

Se realizó un estudio de corte transversal para estimar la prevalencia de asma ocupacional en la población laboral expuesta del municipio Guantánamo durante el período de julio del 2000 a febrero del 2001. El universo de estudio estuvo integrado por 838 trabajadores pertenecientes a la industria sideromecánica y a la construcción; se trabajó con una muestra de 189 trabajadores, quienes fueron seleccionados a través de un muestreo estratificado polietápico. Se encontró que el mayor numero de trabajadores corresponden al sexo masculino, siendo la exposición ocupacional a polvos, y el tiempo de exposición elementos significativos de predicción de asma. Los síntomas y signos encontrados en la serie de estudio, en orden de frecuencia corresponden a la hiperreactividad bronquial con 58.3 (por ciento), tos 25.0 (por ciento), disnea 14.2 (por ciento) y sibilancia 2.3 (por ciento), asociándose la disfunción ventilatoria obstructiva reversible en 52.3 (por ciento) y los resultados positivos del prick- test en 66.7 (por ciento) de los individuos estudiados. Esta última constituye un elemento significativo de predicción de asma. Se detectan, según criterios de Brook, 17 trabajadores con diagnóstico de asma ocupacional, lo que representa una tasa general de 2 (por ciento)(AU)


Subject(s)
Humans , Male , Female , Adult , Asthma/epidemiology , Occupational Diseases/epidemiology , Occupational Medicine/methods , Cross-Sectional Studies
3.
Rev. cuba. hig. epidemiol ; 29(1): 58-65, ene.-jun. 1991. ilus, tab
Article in Spanish | LILACS | ID: lil-102640

ABSTRACT

Se estudiaron 95 trabajadores con más de 5 años de exposición en la industria del niquel "René Ramos Latour", de Nicaro para conocer el estado del aparato respiratorio de estos obreros que inhalan polvo y altas concentraciones de óxido de hierro y niquel. A cada uno de ellos se les llenó un cuestionario para síntomas respiratorios. se les realizó un examen físico riguroso del tórax y radiografía de tórax 14 x 17". y estudios espirométricos. Se encontraron 22 trabajadores con alteraciones funcionales respiratorias y 34 obreros que tenían acúmulo de polvo auque en grado muy precoz, lo cual consideramos está relacionado con la exposición a polvos inhalados


Subject(s)
Humans , Dust/adverse effects , Occupational Exposure , Iron/analogs & derivatives , Nickel
4.
Rev. cuba. hig. epidemiol ; 25(4): 419-38, oct.-dic. 1987. tab
Article in Spanish | LILACS | ID: lil-53213

ABSTRACT

Se realiza una investigación en las 6 plantas procesadoras de bagazo de caña del país. El método que se aplicó para llegar al diagnóstico presuntivo de bagazosis está constituido por 5 criterios, los cuales se enumeran en orden de importancia. El universo de estudio lo constituyeron 1 900 trabajadores, para el diagnóstico presuntivo de bagazosis, durante 20 meses, y se tomó una muestra representativa del 33


Subject(s)
Humans , Male , Female , Occupational Diseases , Pneumoconiosis/diagnosis
5.
Rev. cuba. invest. bioméd ; 6(1): 55-61, ene.-abr. 1987. tab
Article in Spanish | LILACS | ID: lil-53303

ABSTRACT

Se estudian 71 mujeres y 66 hombres que concurrieron al Departamento de Pruebas Funcionales Respiratorias, todos sujetos sanos a quienes se les realizó espirometría como parte de un estudio para determinar su estado de salud. Se analizaron las variables de capacidad vital forzada (CVF), volumen espiratorio forzado en 1 segundo e índice de Tiffenau (VEF1


Subject(s)
Adult , Middle Aged , Humans , Male , Female , Forced Expiratory Volume , Health Status , Spirometry , Vital Capacity
6.
Rev. cuba. invest. bioméd ; 3(2): 167-74, mayo-ago. 1985. tab, ilus
Article in Spanish | LILACS | ID: lil-30951

ABSTRACT

Se compara un espirómetro electrónico digital de reciente adquisición en nuestro país, el Spirotron, con un espirómetro de agua, el Pulmonet III, en 100 trabajadores que concurrieron al Departamento de Pruebas Funcionales Respiratorias del Instituto de Medicina del Trabajo. No se encontraron diferencias significativas en las maniobras de capacidad vital forzada (CVF) y el volumen espiratorio forzado (VEF), relizadas en ambos equipos, por lo que los resultados de las mediciones en el terreno son confiables


Subject(s)
Humans , Male , Female , Spirometry/instrumentation , Forced Expiratory Volume , Vital Capacity
SELECTION OF CITATIONS
SEARCH DETAIL