Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Motriz rev. educ. fís. (Impr.) ; 18(3): 505-514, jul.-set. 2012. graf, tab
Article in Portuguese | LILACS | ID: lil-653579

ABSTRACT

O objetivo do presente estudo foi desenvolver e testar a confiabilidade e validade do Sistema GaitGrabber na obtenção de dados cinemáticos no plano sagital durante a marcha. Dezoito indivíduos participaram do estudo de confiabilidade e 28 do estudo de validade concorrente. O Sistema Qualisys Pro-Reflex foi usado como padrão ouro. O GaitGrabber calcula os ângulos relativos de quadril, joelho e tornozelo no plano sagital. O Coeficiente de Correlação Intraclasse (CCI) foi usado para comparação das médias dos picos angulares entre visitas. Para a validade, foi aplicada a análise de componentes principais. Os CCI variaram de moderados a excelentes e a validade do sistema foi comprovada para o tornozelo. Foi demonstrada diferença significativa na amplitude de movimento de quadril e joelho, a qual foi atribuída a características técnicas dos instrumentos. O Sistema GaitGrabber é válido e confiável e pode ser usado na clínica para análise cinemática da marcha no plano sagital.


The purpose of this study was to develop and test the validity and reliability of the GaitGrabber System in measuring kinematic variables in the sagittal plane during gait. Eighteen individuals participated in the reliability study and 28 in the concurrent validity study. The Qualisys Pro-Reflex System used as a gold standard reference system. The GaitGrabber calculates the relative angles at the hip, knee and ankle in the sagittal plane. The Intraclass Correlation Coefficient (ICC) was used to compare the average of the angular peaks between visits. The principal component analysis was used to test the validity of the system. The ICC ranged from moderate to excellent and the validity of the system was proved for the ankle. There were significant differences in the range of motion for the hip and knee joints which were attributed to different instrumental characteristics. The GaitGrabber system is valid and reliable and can be clinically used to analyze kinematics during gait in the sagittal plane.


Subject(s)
Humans , Male , Female , Adult , Biomechanical Phenomena , Gait/physiology
SELECTION OF CITATIONS
SEARCH DETAIL