Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Rev. CEFAC ; 14(3): 403-412, mayo-jun. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-640886

ABSTRACT

OBJETIVO: comparar os achados das emissões otoacústicas evocadas por estímulos transientes (EOAT) com a timpanometria usando tom sonda de 226 e 1000Hz em lactentes. MÉTODO: o estudo foi realizado no Serviço de Otorrinolaringologia do Hospital Santa Juliana de Maceió - Alagoas. Selecionaram-se lactentes de ambos os gêneros, com faixa etária de recém nascido a seis meses. Foram excluídos aqueles com fissura lábio palatinos, malformação de orelha externa e/ou média, síndromes e história familiar de perda auditiva. Foram realizados os seguintes procedimentos: anamnese para identificar as queixas auditivas e selecionar a amostra de acordo com os critérios de inclusão e exclusão; avaliação otorrinolaringológica por meio de otoscopia e avaliação auditiva que se constituiu de emissões otoacústicas evocadas por estímulo transiente (EOAET) e timpanometria com tom teste da sonda de 226 e 1000Hz. Para analisar as variáveis qualitativas, foi utilizado o teste de Igualdade de Duas Proporções, além do teste Qui-Quadrado para Independência e o intervalo de confiança para a Média, utilizados para a análise das variáveis quantitativas dos resultados. RESULTADOS: comparando-se os resultados das EOAT com os resultados da timpanometria obtida com os tons testes de 226 Hz e 1000Hz , observou-se uma associação da EOAT com a sonda de 1000Hz em ambas as orelhas, ou seja, houve ausência das EOAT nos lactentes que apresentaram timpanogramas alterados e presença quando os timpanogramas estavam normais. CONCLUSÃO: a timpanometria com sonda de 1000 Hz teve maior correlação com as EOAT tanto para identificação de respostas em orelhas normais como para as alterações de orelha média.


PURPOSE: to compare the findings of TEOAE with tympanometry in 226 and 1000 Hz in infants. METHOD: the study was conducted in the Department of Otolaryngology, Hospital Santa Juliana Maceio - Alagoas. We selected infants of both genders, aged from newborn to six months. We excluded those with cleft palate, external and/or middle ear malformation, syndromes, and family history of hearing loss. The following procedures were conducted: anamnesis in order to identify hearing impairment and to select the sample according to the criteria of inclusion and exclusion; otorrinolaringological assessment using otoscopy and hearing evaluation that consisted of transient evoked otoacoustic emissions (TEOAE) and tympanometry with 226 and 1000Hz probe tones. In order to analyze the qualitative variables, we used the test for Equality of Two Proportions, and the Chi-Square for Independence and the confidence interval for the average used for the analysis of the results of quantitative variables. RESULTS: comparing the results of TEOAE with the tympanometry results that were obtained with 226Hz and 1000Hz probe tones, we observed an association of TEOAE with the 1000Hz probe for both ears, the infants with TEOAEs absence had altered tympanogram results and the ones where the TEOAEs were present had normal tympanograms. CONCLUSION: There was a higher correlation between the results of the 1000 Hz probe tympanometry and the TEOAE in order to identify normal ear responses and middle ear disorders.

2.
Rev. Soc. Bras. Fonoaudiol ; 17(2): 156-160, abr.-jun. 2012. tab
Article in Portuguese | LILACS | ID: lil-639575

ABSTRACT

OBJETIVO: Analisar e comparar o gradiente timpanométrico e a compliância obtida nas sondas de 226 Hz e 1 kHz entre os grupos de lactentes com e sem refluxo gastroesofágico. MÉTODOS: Cento e dezoito lactentes a termo e pré-termo, de recém-nascidos a 6 meses de idade - 63 com diagnóstico clínico de refluxo gastroesofágico fisiológico realizado por pediatras ou gastropediatras e 55 sem refluxo -, foram submetidos a timpanometria com sondas de 226 Hz e 1 kHz. RESULTADOS: Foram observados maiores valores de compliância com sonda de 1 kHz em ambos os grupos. Ao se comparar a média de compliância entre os grupos, observou-se que o grupo sem refluxo apresentou maiores valores. A média dos valores do gradiente timpanométrico foi maior no grupo sem refluxo, quando comparada ao grupo com refluxo. CONCLUSÃO: A sonda de 1 kHz apresenta maior compliância em lactentes com e sem refluxo, em relação à sonda de 226 Hz. Lactentes com refluxo apresentam compliância dentro dos padrões de normalidade, porém apresentando menor compliância quando comparados com lactentes sem refluxo. Com relação ao gradiente, lactentes com refluxo apresentam valores alterados e/ou dentro dos padrões limítrofes da normalidade, em ambas as orelhas.


PURPOSE: To analyze and compare the tympanometric gradient and the compliance obtained in probe tones of 226 and 1 kHz between groups of infants with and without gastroesophageal reflux (GER). METHODS: Participants were 118 full-term and preterm infants, from newborns to 6-month-olds - 63 with clinical diagnosis of physiological GER performed by pediatricians or gastroenterologists, and 55 without GER -, who were submitted to tympanometry with probe tones of 226 and 1 kHz. RESULTS: Higher compliance values were found with 1 kHz in both groups. Comparing the average compliance between groups, we observed that the group without reflux showed higher values. The mean value of the tympanometric gradient was higher in the group without reflux, when compared to the one with reflux. CONCLUSION: The 1 kHz probe tone has higher compliance in infants with and without GER, when compared to the 226 Hz probe tone. Infants with reflux have compliance within normal limits, although they present lower compliance than infants without reflux. Regarding the gradient, infants with GER have altered values and/or within normality limits in both ears.

3.
Arq. int. otorrinolaringol. (Impr.) ; 15(3): 295-301, jul.-set. 2011. graf, tab
Article in Portuguese | LILACS | ID: lil-606450

ABSTRACT

INTRODUÇÃO: As emissões otoacústicas evocadas por estímulo transiente (EOAT) têm sido a técnica mais utilizada para a realização da triagem auditiva neonatal. Sendo importante analisar suas medidas correlacionando com outras alterações que pode acometer o sistema auditivo da criança. OBJETIVO: Analisar a ocorrência e os níveis de resposta das emissões otoacústicas evocadas por estímulo transiente em lactentes com refluxo gastroesofágico fisiológico (RGEF). MÉTODO: Estudo prospectivo foi realizado no Serviço de Otorrinolaringologia do Hospital Santa Juliana. Participaram do estudo 118 bebês, de recém nascidos há seis meses, encaminhados por pediatras e gastropediatras, nascidos pré-temo ou termo e distribuídos em dois grupos: Grupo Estudo: 63 lactentes com diagnóstico clínico de refluxo gastroesofágico fisiológico, e Grupo Controle: 55 lactentes sem refluxo gastroesofágico fisiológico. Foi realizada a avaliação da função auditiva periférica por meio dos exames de emissões otoacústicas evocadas por estímulo transiente e otoscopia realizada por otorrinolaringologista. RESULTADOS: Os níveis médios de respostas das emissões otoacústicas evocadas por estímulo transiente foram maiores no grupo sem refluxo para as bandas de frequências de 2kHz, 2,5kHz, 3kHz, 3,5kHz e 4,5kHz bilateralmente, com diferenças estatisticamente significantes, obtendo-se valores médios de 7,71dB e 7dB na orelha direita, encontrados nas bandas de frequências de 2 e 4kHz, respectivamente. CONCLUSÃO: Houve menor ocorrência e menor nível de respostas das emissões otoacústicas transientes em crianças com refluxo gastroesofágico fisiológico quando comparados a crianças sem refluxo.


INTRODUCTION: The transient-evoked otoacoustic emissions (TEOAE) have been the most widespread technique to perform neonatal hearing screening. Scrutinizing their measures by way of an association with other alterations that may impair the infant's auditory system is important. OBJECTIVE: Analyze the incidence and the response levels of the transient-evoked otoacoustic emissions on infants having a physiological gastroesophageal reflux disease (GERD). METHOD: A prospective study was performed at Santa Juliana Hospital's Otorhinolaryngology Department. 118 prematurely-born and timely-born babies, from newly-born to 6 months old, who were sent by pediatricians and gastropediatricians, participated in the study and they were divided into two groups: Study Group: 63 infants clinically diagnosed of a physiological gastroesophageal reflux disease, and Control Group: 55 infants without a physiological gastroesophageal reflux. The peripheral hearing function was evaluated by both transient-evoked otoacoustic emissions and otoscopy examinations performed by an otorhinolaryngologist. RESULTS: The average response levels of the transient-evoked otoacoustic emissions were higher in the non-reflux group for frequency bands of 2kHz, 2. 5kHz, 3kHz, 3. 5kHz and 4. 5kHz bilaterally, with a statistically significant difference, achieving the average values of 7. 71dB and 7dB in the right ear found in the frequency bands of 2 and 4kHz, respectively. CONCLUSION: There was a lower incidence and a lower response level of the transient-evoked otoacoustic emissions in physiological gastroesophageal reflux children in comparison with children having no reflux.


Subject(s)
Humans , Male , Female , Infant , Gastroesophageal Reflux , Hearing , Otoacoustic Emissions, Spontaneous
4.
Arq. bras. med ; 59(6): 407-16, dez. 1985. tab
Article in Portuguese | LILACS | ID: lil-30277

ABSTRACT

Em uma série de oito pacientes, os autores mostram os principais aspectos clínicos e achados laboratoriais da SIDA, que têm sido freqüentemente identificados entre nós. Mostram, também, os achados anatomopatológicos de cinco casos necropsiados e tecem alguns comentários sobre essa síndrome, que tem preocupado todo o mundo


Subject(s)
Acquired Immunodeficiency Syndrome
SELECTION OF CITATIONS
SEARCH DETAIL