1.
Rev. cuba. oftalmol ; 23(supl.1): 531-544, 2010.
Article in Spanish | LILACS | ID: lil-615590

ABSTRACT

OBJETIVO: Determinar la efectividad de la fórmula de Haigis en el cálculo del poder dióptrico del lente intraocular. MÉTODOS: Se realizó un estudio descriptivo prospectivo, de pacientes operados de catarata mediante la técnica de Facoemulsificación en el Servicio de Microcirugía del Instituto Cubano de Oftalmología Ramón Pando Ferrer entre enero 2007 a enero 2008. Para el cálculo del poder del lente intraocular se empleó el IOL Máster y la fórmula de Haigis. La muestra de 101 pacientes, se seleccionó por el método aleatorio simple, de los cuales 28 fueron intervenidos en ambos ojos, para un total de 129 ojos. RESULTADOS: El equivalente esférico preoperatorio y posoperatorio no tuvieron diferencias, sí existieron entre esfera esperada y la obtenida. La mayor diferencia entre la esfera esperada y la obtenida fue encontrada en los pacientes hipermétropes. El astigmatismo refractivo fue bajo. La longitud axil posoperatoria no se modificó y la mejor agudeza visual sin corrección y con corrección mejoró en más de cuatro líneas en la cartilla de Snellen CONCLUSIÓN: Se demostró la efectividad de la fórmula de Haigis en el cálculo del poder del lente intraocular


OBJECTIVE: To determine the effectiveness of Haigis´formula in the intraocular lens power calculation. METHODS: A prospective and descriptive study was conducted in patients operated from cataract with phacoemulsification technique at the Microsurgery Service of Ramón Pando Ferrer Cuban Institute of Opththalmology from January 2007 to January 2008. The IOL Master and the Haigis´formula were used for the intraocular lens power calculation. The sample of 101 patients was selected by the simple random method, of whom 28 underwent surgery in both eyes, for a total number of 129 eyes. RESULTS: The Pre- and the post-operative spherical equivalents did not have any differences; but the expected sphere and the real sphere did show differences. The biggest difference between the expected sphere and the real one was found in the hypermetropic patients. The refractive astigmatism was low. The postoperative axil length did not change and the best visual acuity without/ with Correction improved by more than four lines in the Snellen´s chart. CONCLUSION: The effectiveness of Haigis´ formula was confirmed in the intraocular lens power calculation


Subject(s)
Humans , Male , Female , Middle Aged , Visual Acuity/physiology , Cataract Extraction/statistics & numerical data , Phacoemulsification/methods , Tomography, Optical Coherence/methods , Epidemiology, Descriptive , Longitudinal Studies , Observational Studies as Topic , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL