Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
J. pediatr. (Rio J.) ; 92(4): 400-408, July-Aug. 2016. tab, graf
Article in English | LILACS | ID: lil-792581

ABSTRACT

Abstract Objective To generate prediction equations for spirometry in 4- to 6-year-old children. Methods Forced vital capacity, forced expiratory volume in 0.5 s, forced expiratory volume in one second, peak expiratory flow, and forced expiratory flow at 25–75% of the forced vital capacity were assessed in 195 healthy children residing in the town of Sete Lagoas, state of Minas Gerais, Southeastern Brazil. The least mean squares method was used to derive the prediction equations. The level of significance was established as p < 0.05. Results Overall, 85% of the children succeeded in performing the spirometric maneuvers. In the prediction equation, height was the single predictor of the spirometric variables as follows: forced vital capacity = exponential [(−2.255) + (0.022 × height)], forced expiratory volume in 0.5 s = exponential [(−2.288) + (0.019 × height)], forced expiratory volume in one second = exponential [(−2.767) + (0.026 × height)], peak expiratory flow = exponential [(−2.908) + (0.019 × height)], and forced expiratory flow at 25–75% of the forced vital capacity = exponential [(−1.404) + (0.016 × height)]. Neither age nor weight influenced the regression equations. No significant differences in the predicted values for boys and girls were observed. Conclusion The predicted values obtained in the present study are comparable to those reported for preschoolers from both Brazil and other countries.


Resumo Objetivo Gerar equações de predição da espirometria em crianças de quatro a seis anos. Métodos Capacidade vital forçada, volume expiratório forçado em 0,5 segundo, volume expiratório forçado em um segundo, pico de fluxo expiratório e fluxo expiratório forçado com 25-75% da capacidade vital forçada foram avaliados em 195 crianças saudáveis que residem em Sete Lagoas, Estado de Minas Gerais, Sudeste do Brasil. O método dos mínimos quadrados foi usado para derivar as equações de predição. O nível de significância foi estabelecido como p < 0,05. Resultados No geral, 85% das crianças foram bem-sucedidas ao fazer as manobras espirométricas. Na equação de predição, a estatura foi a única variável preditora das variáveis espirométricas, da seguinte forma: capacidade vital forçada = exponencial [(-2,255) + (0,022 x estatura)], volume expiratório forçado em 0,5 segundo = exponencial [(-2,288) + (0,019 x estatura)], volume expiratório forçado em um segundo = exponencial [(-2,767) + (0,026 x estatura)], pico do fluxo expiratório = exponencial [(-2,908) + (0,019 x estatura)] e fluxo expiratório forçado com 25-75% da capacidade vital forçada = exponencial [(-1,404) + (0,016 x estatura)]. Nem a idade nem o peso influenciaram as equações de regressão. Não foi observada diferença significativa nos valores previstos em meninos e meninas. Conclusão Os valores previstos obtidos neste estudo são comparáveis àqueles relatados em crianças em idade pré-escolar tanto do Brasil quanto de outros países.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Algorithms , Peak Expiratory Flow Rate/physiology , Vital Capacity/physiology , Forced Expiratory Volume/physiology , Reference Standards , Reference Values , Spirometry/methods , Time Factors , Anthropometry , Predictive Value of Tests , Reproducibility of Results , Analysis of Variance , Age Factors , Statistics, Nonparametric
2.
Fisioter. pesqui ; 22(3): 275-281, jul.-set. 2015. tab, graf
Article in English | LILACS | ID: lil-767874

ABSTRACT

RESUMO É importante avaliar a função pulmonar em pré-escolares. Poucos estudos relacionados aos testes de função pulmonar nessa população estão disponíveis. O objetivo deste estudo foi avaliar a taxa de sucesso e reprodutibilidade teste-reteste do pico de fluxo da tosse (PFT) em uma amostra de crianças com idade entre 4 e 6 anos. O PFT foi estudado em 44 crianças saudáveis (26 meninos e 18 meninas), selecionadas de acordo com o questionário ATS-DLD-78-C, utilizado para detectar a presença de doenças respiratórias de base e exposição ambiental. O medidor de pico de fluxo expiratório (Piko-I Electronic Peak Flow Meter, Pulmonary Data Services, USA) foi usado para mensurar o PFT. A taxa de sucesso foi definida como a porcentagem de crianças capazes de realizar o teste de acordo com os critérios de aceitabilidade e reprodutibilidade. Para avaliar a reprodutibilidade teste-reteste, 10 crianças (de acordo com o cálculo amostral) foram reavaliadas após três semanas. A reprodutibilidade teste-reteste foi avaliada pelo teste t pareado, considerando significativo p<0,05 e coeficiente de correlação intraclasse (CCI). Os resultados mostraram uma taxa de sucesso de 91% para PFT, sendo de 80, 88 e 100% para crianças com 4, 5 e 6 anos, respectivamente. Quanto à reprodutibilidade teste-reteste, não houve diferença significativa entre os dados da primeira avaliação e da reavaliação (p=0,39) e foi observado CCI de 0,84. Esses resultados sugerem elevada taxa de sucesso na realização do PFT e reprodutibilidade teste-reteste de magnitude excelente para essa variável em pré-escolares saudáveis.


RESUMEN La evaluación de la función pulmonar en niños en edad preescolar es importante pues hay pocos estudios que investigan los test de función pulmonar en este grupo. Este estudio tuvo el propósito de evaluar la tasa de éxito y la reproducibilidad test-retest del pico de flujo de tos (PFT) en una muestra con niños entre 4 y 6 años de edad. Se estudió el PFT en 44 participantes saludables (26 chicos y 18 chicas) elegidos a través de un cuestionario ATS-DLD-78-C para detectar la presencia de enfermedades respiratorias de base y exposición ambiental. Se utilizó el medidor del pico de flujo espiratorio (Piko-I Electronic Peak Flow Meter, Pulmonary Data Services, USA) para medir el PFT. Se definió la tasa de éxito como el porcentaje de niños capaces de realizar el test según los criterios de aceptabilidad y de reproducibilidad. Para evaluar la reproducibilidad test-retest tras tres semanas se reevaluaron 10 niños según el cálculo de la muestra. Se analizó la reproducibilidad a través del test t pareado, considerando significativo <0,05 y el coeficiente de correlación intraclase (CCI). Los resultados mostraron una tasa de éxito del 91% para el PFT, siendo un 80, 88 y 100% para niños con 4, 5 y 6 años, respectivamente. En cuanto a la reproducibilidad test-retest no hubo diferencias significativas entre los datos de la primera evaluación y de la reevaluación (p=0,39) en que se observó el CCC de 0,84. Estos resultados proponen alta tasa de éxito en la ejecución del PFT y excelente reproducibilidad test-retest en esa variable en niños saludables en edad preescolar.


ABSTRACT It is important to evaluate lung function in preschoolers. There are few studies related to pulmonary function tests with this part of the population. The purpose of this study was to evaluate the success rate and test-retest reproducibility of the cough peak flow (CPF) in a sample with children between four and six years old. The CPF was tested in 44 healthy children (26 boys, 18 girls), selected according to the ATS-DLD-78-C questionnaire, used to detect the presence of common respiratory diseases or induced by environmental exposure. An expiratory peak flow meter (Piko-I Electronic Peak Flow Meter, Pulmonary Data Services, USA) was used to measure CPF. The success rate was defined as the percentage of children able to perform the test according to the acceptability and reproducibility criteria. To evaluate the test-retest reproducibility, 10 children (according with the sample calculation) were reevaluated after three weeks. The study was approved by the Ethics Research Committee of the Institution. The test-retest reproducibility was evaluated by the paired t-test, considering a significance of p<0.05 and intraclass correlation coefficient (ICC). The results showed a success rate of 91% for CPF, with 80%, 88% and 100% for children with four, five and six years, respectively. Regarding the test-retest reproducibility, there was no significant difference between data of the first assessment and reassessment (p=0.39) and an ICC of 0.84 was observed. These results suggest an elevated success rate in the performance of CPF and an excellent test-retest reproducibility for this variable in healthy preschoolers.

3.
Fisioter. mov ; 26(1): 141-150, jan.-mar. 2013. graf, tab
Article in English | LILACS | ID: lil-670337

ABSTRACT

INTRODUCTION: Thoracoabdominal-TA asynchrony is an important sign of Chronic Obstructive Pulmonary Disease (COPD). Studies investigating the influence of endurance training on TA asynchrony have not been found. OBJECTIVE: To analyze lower-limb endurance training effects on TA asynchrony in patients with COPD. MATERIALS AND METHODS: Two patients with severe COPD were evaluated in a single-subject design AB (A-baseline for six weeks, B-training on cycle ergometer with intensity of 70% of baseline peak load, for 12 weeks) with repeated measures of variables: phase inspiratory relation (PhRIB), phase expiratory relation (PhREB) and phase angle (PhAng). These variables were assessed by respiratory inductive plethysmography during incremental exercise tests on a cycle ergometer (same load and peak load of each test). Statistical methods included visual analysis, two-standard deviation band test and split middle line test, considering significant p < 0.05. It was considered the results for variables with agreement of at least two analyses. Data are presented as mean ± SD for phases A and B. RESULTS: During phase B, Patient 1 presented significant decrease of PhRIB (22.7 ± 3.4 x 17.0 ± 4.9) and PhAng (16.5 ± 5.1 x 13.2 ± 2.1) for same load and PhREB (16.8 ± 3.1 x 13.3 ± 3.1) and PhAng (23.4 ± 1.7 x 20.1 ± 2.3) at peak load. Patient 2 showed significant decrease of PhRIB for same load and (14.4 ± 3.8 x 13.9 ± 3.9) at peak load (19.1 ± 2.5 x 15.7 ± 2.7). CONCLUSIONS: These results suggest that lower-limb endurance training reduced TA asynchrony in patients with severe COPD. The findings may be related, according to the literature, to the lower ventilatory demand and greater exercise capacity of patients with COPD undergoing endurance training.


INTRODUÇÃO: A assincronia toracoabdominal (TA) é um importante sinal da Doença Pulmonar Obstrutiva Crônica (DPOC). Estudos investigando a influência do treinamento de endurance sobre assincronia TA não foram encontrados. OBJETIVO: Analisar as repercussões do treinamento de endurance dos membros inferiores-MMI sobre a assincronia TA em indivíduos com DPOC. MATERIAIS E MÉTODOS: Dois pacientes com DPOC grave foram avaliados em um estudo experimental de caso único AB (A-baseline por seis semanas, B-treinamento em cicloergômetro com intensidade de 70% da carga pico atingida no baseline, por 12 semanas) com medidas repetidas das variáveis: relação da fase inspiratória (PhRIB), relação da fase expiratória (PhREB) e ângulo de fase (PhAng). Essas variáveis foram analisadas pela pletismografia respiratória por indutância durante testes de exercício incremental em cicloergômetro (isocarga e carga pico em cada teste). Os métodos estatísticos incluíram análise visual, two-standard deviation band e split middle line test, considerando significativo p < 0,05. Foram considerados os resultados com concordância de pelo menos duas análises. RESULTADOS: Durante a fase B, o paciente 1 apresentou redução significativa da PhRIB (22,7 ± 3,4 x 17,0 ± 4,9) e PhAng (16,5 ± 5,1 x 13,2 ± 2,1) para isocarga e PhREB (16,8 ± 3.1 x 13,3 ± 3,1) e PhAng (23,4 ± 1,7 x 20,1 ± 2,3) na carga pico. O paciente 2 mostrou redução significativa do PhRIB para isocarga (14,4 ± 3,8 x 13,9 ± 3,9) e na carga pico (23,4 ± 1,7 x 20,1 ± 2,3). CONCLUSÕES: Os resultados sugerem que o treinamento de resistência dos MMII reduziu a assincronia TA nos pacientes avaliados. Os resultados podem estar relacionados, de acordo com a literatura, com a menor demanda ventilatória e maior capacidade de exercício dos pacientes submetidos a um treinamento de endurance.


Subject(s)
Humans , Exercise , Pulmonary Disease, Chronic Obstructive , Rehabilitation , Physical Therapy Specialty
SELECTION OF CITATIONS
SEARCH DETAIL