Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Rev. bras. cir. cardiovasc ; 33(4): 362-370, July-Aug. 2018. tab, graf
Article in English | LILACS | ID: biblio-958425

ABSTRACT

Abstract Objective: To analyze the behavior of platelets after transcatheter valve-in-valve implantation for the treatment of degenerated bioprosthesis and how they correlate with adverse events upon follow-up. Methods: Retrospective analysis of 28 patients who received a valve-in-valve implant, 5 in aortic, 18 in mitral and 5 in tricuspid positions. Data were compared with 74 patients submitted to conventional redo valvular replacements during the same period, and both groups' platelet curves were analyzed. Statistical analysis was conducted using the IBM SPSS Statistics(r) 20 for Windows. Results: All patients in the valve-in-valve group developed thrombocytopenia, 25% presenting mild (<150.000/µL), 54% moderate (<100.000/µL) and 21% severe (<50.000/µL) thrombocytopenia. The platelet nadir was on the 4th postoperative day for aortic ViV, 2nd for mitral and 3rd for tricuspid patients, with the majority of patients recovering regular platelet count. However, the aortic subgroup comparison between valve-in-valve and conventional surgery showed a statistically significant difference from the 7th day onwards, where valve-in-valve patients had more severe and longer lasting thrombocytopenia. This, however, did not translate into a higher postoperative risk. In our study population, postoperative thrombocytopenia did not correlate with greater occurrence of adverse outcomes and only normal preoperative platelet count could significantly predict a postoperative drop >50%. Conclusion: Although thrombocytopenia is an extremely common finding after valve-in-valve procedures, the degree of platelet count drop did not correlate with greater incidence of postoperative adverse outcomes in our study population.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Postoperative Complications/etiology , Postoperative Complications/blood , Thrombocytopenia/etiology , Thrombocytopenia/blood , Heart Valve Prosthesis Implantation/adverse effects , Platelet Count/methods , Reference Values , Reoperation , Time Factors , Tricuspid Valve/surgery , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Predictive Value of Tests , Retrospective Studies , Risk Factors , Treatment Outcome , Statistics, Nonparametric , Risk Assessment , Heart Valve Prosthesis Implantation/methods , Transcatheter Aortic Valve Replacement/adverse effects , Mitral Valve/surgery
2.
Rev. bras. cir. cardiovasc ; 33(3): 224-232, May-June 2018. tab, graf
Article in English | LILACS | ID: biblio-958406

ABSTRACT

Abstract Objective: Hemodilution is a concern in cardiopulmonary bypass (CPB). Using a smaller dual tubing rather than a single larger inner diameter (ID) tubing in the venous limb to decrease prime volume has been a standard practice. The purpose of this study is to evaluate these tubing options. Methods: Four different CPB circuits primed with blood (hematocrit 30%) were investigated. Two setups were used with two circuits for each one. In Setup I, a neonatal oxygenator was connected to dual 3/16" ID venous limbs (Circuit A) or to a single 1/4" ID venous limb (Circuit B); and in Setup II, a pediatric oxygenator was connected to dual 1/4" ID venous limbs (Circuit C) or a single 3/8" ID venous limb (Circuit D). Trials were conducted at arterial flow rates of 500 ml/min up to 1500 ml/min (Setup I) and up to 3000 ml/min (Setup II), at 36°C and 28°C. Results: Circuit B exhibited a higher venous flow rate than Circuit A, and Circuit D exhibited a higher venous flow rate than Circuit C, at both temperatures. Flow resistance was significantly higher in Circuits A and C than in Circuits B (P<0.001) and D (P<0.001), respectively. Conclusion: A single 1/4" venous limb is better than dual 3/16" venous limbs at all flow rates, up to 1500 ml/min. Moreover, a single 3/8" venous limb is better than dual 1/4" venous limbs, up to 3000 ml/min. Our findings strongly suggest a revision of perfusion practice to include single venous limb circuits for CPB.


Subject(s)
Humans , Oxygenators/standards , Cardiopulmonary Bypass/instrumentation , Cannula/standards , Pediatrics/instrumentation , Reference Standards , Temperature , Time Factors , Venous Pressure/physiology , Blood Flow Velocity/physiology , Cardiopulmonary Bypass/methods , Reproducibility of Results , Equipment Design , Equipment Safety , Hemodilution , Models, Cardiovascular
SELECTION OF CITATIONS
SEARCH DETAIL