Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Chinese Journal of Traumatology ; (6): 45-48, 2017.
Article in English | WPRIM | ID: wpr-330445

ABSTRACT

<p><b>PURPOSE</b>Fractures of the lateral end of the clavicle are relatively uncommon. These fractures are unstable due to the various deforming forces which act on the fragments as well as the small distal fracture fragment. At most times the deforming forces are not taken into consideration, and the fracture is not fixed securely. In this study, we assessed a fixation technique using the precontoured locking plates to find out whether it provided a stable fixation with good functional outcome.</p><p><b>METHODS</b>Totally, 32 patients with lateral end clavicle fracture (Neer's Type II) were included in the study. After the informed consent and preoperative investigations were obtained, open reduction and internal fixation was done using a 3.5 mm precontoured superior locking plate with lateral extension under general anesthesia. Postoperative X-rays were done on day 1 and every 6 weeks after operation, until radiological union was achieved. The postoperative pain was assessed using Visual Analogue Scale (VAS) on postoperative days 1, 2 and 10. Postoperatively arm pouch sling was given for 2 weeks followed by active mobilization. Patients were asked to do their daily routine work and avoid lifting heavy weights. The functional outcome was assessed at the end of 2nd and 6th months with the help of Disabilities of the Arm, Shoulder and Hand (DASH) scoring.</p><p><b>RESULTS</b>There were no intraoperative complications in the procedure. The mean VAS score on postoperative day 1 was found to be 5 which decreased to 3 on day 2 and 0 on day 10. The mean DASH score was calculated as 11.63 at the end of postoperative month 2 and then 4.6 at the end of month 6. There was one case of malunion in whom the overhead abduction was restricted but was not painful and was managed conservatively.</p><p><b>CONCLUSION</b>The precontoured locking plates with lateral extension may be a good method to fix the fractures of the lateral end clavicle, which provide a stable fixation with good functional outcome with very few instances of stiffness and decreased range of motion of the shoulder with the hook plates and failure of fixation in screw and K-wire fixations. It may well be the answer to the fixation questions of the lateral clavicle fractures, although larger comparative studies between the surgical treatment methods are required to confirm the same.</p>


Subject(s)
Adolescent , Adult , Humans , Bone Plates , Clavicle , Wounds and Injuries , General Surgery , Fracture Fixation, Internal , Methods , Fractures, Bone , Diagnostic Imaging , General Surgery , Pain Measurement
2.
Chinese Journal of Traumatology ; (6): 286-289, 2016.
Article in English | WPRIM | ID: wpr-235727

ABSTRACT

The management of multiple complicated injured patients remains a great challenge despite advance- ments in modern medical care. We present a rare case of bilateral unstable pelvic fractures associated with bilateral segmental femoral shaft fractures.We have proposed a mechanism of such complex injury pattern and discussed the plan of management. We believe that a timely and aggressive surgical intervention to fix all the major fractures soon after medically stabilizing the patient helped our patient to overcome these serious and lethal injuries. It is necessary to establish an optimal protocol for management of such complex fractures by conducting prospective and multicentric studies in the future.


Subject(s)
Adult , Female , Humans , Femoral Fractures , Diagnostic Imaging , General Surgery , Pelvic Bones , Diagnostic Imaging , Wounds and Injuries
3.
Chinese Journal of Traumatology ; (6): 241-244, 2015.
Article in English | WPRIM | ID: wpr-316809

ABSTRACT

Constrained total knee prostheses are used in knees with severe deformities and insufficiency of collaterals to provide stable and mobile knees. Dislocation after constrained knee prosthesis is an extremely rare and dreaded complication. When dislocation is associated with patellar tendon rupture, the management includes restoration of the extensor apparatus along with a stable knee. Repair of the patellar tendon is challenging due to poor soft tissue coverage in the area and a bulky repair can put tension on the wound closure. Ideal method of restoration of the extensor apparatus is a matter of debate. There are various modalities used ranging from primary end-to-end repair, augmentation by medial gastrocnemius flap, semitendinosus and synthetic implants and allograft tendoachilles. We report a rare case of a posterior dislocation of a constrained total knee arthroplasty in association with patellar tendon rupture due to a minor fall after a few weeks of surgery. The first episode was managed by reposition of the dislocation and V-Y plasty of the quadriceps and primary repair. The second episode of dislocation with re-rupture needed augmentation by semitendinosus along with the insertion of the thicker insert. The management of this complex problem along with the review of literature is discussed in this case report.