Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Rev. colomb. anestesiol ; 50(1): e201, Jan.-Mar. 2022. tab, graf
Article in English | LILACS | ID: biblio-1360945

ABSTRACT

Abstract Introduction Endotracheal intubation is a procedure associated with a high level of exposure to the COVID-19 virus. This has led to the search of alternatives to reduce the risk of contamination, including the so-called aerosol box. Objective To compare time and difficulty of orotracheal intubation when using the aerosol box in a simulated setting. Methodology Observational study conducted with the participation of 33 anesthetist physicians and anesthesia residents; groups were compared in terms of time and intubation difficulty using a conventional Macintosh laryngoscope and the McGRATH™ MAC (Medtronic) videolaryngoscope with or without aerosol box. In order to determine performance with the intubation maneuver, crude hazard ratios were estimated, and a Cox multivariate regression model was built, adjusted by anesthetist years of experience and difficulties during the procedure. Results On average, the aerosol box increased intubation time by 7.57 seconds (SD 8.33) when the videolaryngoscope was used, and by 6.62 (SD 5.74) with the Macintosh. Overall, 132 intubations were performed, with 121 successful and 6 failed first-time attempts (4 with the use of the aerosol box); 16 participants (48.48%) reported difficulty handling the box. With the use of the Macintosh, intubation was found to be faster than with the videolaryngoscope (cHR: 1.36 [95% CI 0.64-2.88]; adjusted HR: 2.20 [95% CI 0.73-6.62]). Conclusions The use of the aerosol box and personal protective equipment in a simulation setting hinders the intubation maneuver and may result in protracted execution time.


Resumen Introducción La intubación endotraqueal es un procedimiento que se relaciona con alto nivel de exposición al virus de COVID-19, llevando a la búsqueda de alternativas para disminuir el riesgo de contaminación, entre ellas la llamada Caja de aerosoles. Objetivo Comparar el tiempo y dificultad en la intubación orotraqueal usando la caja de aerosoles en escenarios simulados. Metodología Estudio observacional, con participación de 33 médicos anestesiólogos y residentes de anestesia; se compararon los grupos en tiempo y dificultad de intubación con uso de laringoscopio convencional Macintosh y videolaringoscopio McGRATH™ MAC (Medtronic) utilizando la caja de aerosoles y sin ella. Para determinar el rendimiento en la maniobra de intubación se calcularon Hazard ratios crudos, se construyó modelo multivariado de Regresion de Cox ajustado por años de experiencia como anestesiólogo y dificultades durante el procedimiento. Resultados La caja de aerosoles aumentó en promedio el tiempo en segundos para la intubación con video-laringoscopio en 7,57 (DE: 8,33) y con Macintosh 6,62 (DE: 5,74). Se llevaron a cabo 132 intubaciones, 121 exitosas en el primer intento y 6 fallidas (4 con el uso de la caja de aerosoles). 16 participantes reconocieron alguna dificultad al manipular la caja (48,48 %). Con el uso de Macintosh se identificó tendencia a la intubación más rápido que con el videolaringoscopio (HRc: 1,36 [IC 95 %: 0,64-2,88]; HR ajustado: 2,20 [IC 95 %: 0,73-6,62]). Conclusiones Utilizar la caja de aerosoles y equipo de protección personal en un escenario simulado dificulta la maniobra de intubación y puede prolongar el tiempo de ejecución.


Subject(s)
Pancreas Divisum
2.
Rev. chil. anest ; 48(2): 115-122, 2019. ilus, tab
Article in Spanish | LILACS | ID: biblio-1451686

ABSTRACT

Electric burns are consider one of the most drastic traumas that an individual can be expose to, it compromise almost all systems of the human body. It is important to acknowledge all the general characteristics of electricity, the mechanism and the types of injuries, these are not well known by health providers. Our article is based on a bibliographic research to obtain an extend review that allows the reader comprehend the physiopathology of electric burns and apply it to the daily working basis.


Las quemaduras eléctricas son consideradas uno de los traumas más drásticos al cual puede exponerse un individuo; comprometiendo directa o indirectamente a casi todos los sistemas del cuerpo humano. Es importante conocer los aspectos generales de la electricidad, los mecanismos y tipos de lesiones generadas por las mismas, que son poco comprendidos por la mayoría del personal de salud. Nuestro artículo se basa en una revisión bibliográfica para ofrecer una explicación completa, que permita al lector entender mejor la fisiopatología de este tipo de trauma y, por lo tanto, se manifieste en el actuar diario del personal de salud.


Subject(s)
Humans , Burns, Electric/physiopathology
3.
Rev. argent. cir. plást ; 24(2): 51-56, 20180000. fig
Article in Spanish | LILACS, BINACIS | ID: biblio-1358127

ABSTRACT

Las quemaduras eléctricas son consideradas uno de los traumas más drásticos al cual puede verse expuesto un individuo, que afecta directa o indirectamente a casi todos los sistemas del cuerpo humano. Este tipo de trauma tiene efectos locales y sistémicos poco comprendidos por la mayoría del personal de salud. El objetivo de éste artículo es ofrecer una explicación completa, que permita al lector entender mejor la fisiopatología de este tipo de trauma y por lo tanto se manifieste en el actuar diario del personal de salud.


Electric burns are one of the most drastic traumas to which an individual can be exposed, They can directly or indirectly compromise almost all the systems of the human body, this type of trauma has local and systemic effects little understood by the majority of health personnel. The objective of this article is to offer a complete explanation, allowing the reader to better understand the pathophysiology of this type of trauma and therefore manifest in the daily actions of health personnel.


Subject(s)
Humans , Burn Units , Burns, Electric/surgery , Burns, Electric/complications , Burns, Electric/physiopathology , Burns, Electric/mortality , Accidental Injuries/complications
4.
Rev. chil. anest ; 47(2): 97-101, jun. 11 2018.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-965952

ABSTRACT

Supraventricular tachycardia is one of the tachyarrhythmias that do not have its origin in one organic cardiomyopathy. Generally, they have a good prognosis, and its clinical spectrum varies from asymptomatic patients to those with low cardiac output. Treatment will depend on the hemodynamic stability of the pa- tient. The objective of this case report is to make a review on existent literature about adverse cardiac effects with the use of Glycine in patients after urologic surgery.


La taquicardia supraventricular hace parte del grupo de taquiarritmias que no se originan de una cardiopatía orgánica existente y por lo general son de buen pronóstico. Su espectro clínico abarca desde pacientes asintomáticos hasta aquellos con signos de bajo gasto cardíaco que requerirán tratamiento según su estabilidad hemodinámica. El objetivo del presente reporte de caso es realizar una revisión de la literatura sobre los efectos adversos asociados a la irrigación vesical continúa con glicina en un paciente a quien se le realizó prostatectomía.

SELECTION OF CITATIONS
SEARCH DETAIL