1.
China Occupational Medicine ; (6): 697-2022.
Article in Chinese | WPRIM | ID: wpr-976106

ABSTRACT

@#Objective - - To prepare the GDH 5 air sampling tube for simultaneous collection of eight kinds of chloro nitrobenzene ( ) , compounds CNBs in the air of workplace and establish a matching determination method using gas chromatography. Methods - - , Eight kinds of CNBs in vapor and aerosol state were collected by self developed GDH 5 air sampling tube desorbed , , , by toluene separated by polysiloxane gas chromatography column detected by microcell electron capture detector and Results - ( - quantified by external standard method. It was determined that the air sampling tube was assembled by XAD 2 ion ) - , exchange resin and glass fiber filter membrane. The linear range of CNBs was 0.80 240.00 mg/L and the linear correlation - - coefficients were greater than 0.999 9. The detection limit was 7.87 13.03 μg/L. The minimum detectable concentration was 0.60 3, - 3( ) 1.33 μg/m and the minimum quantitative concentration was 2.00 4.22 μg/m sample 45.00 L . The average desorption - - (RSD) - , - RSD efficiency was 101.2% 110.0%. The within run relative standard deviation was 0.8% 4.1% and the between run - Conclusion - was 0.3% 5.8%. The samples could be stored for more than 30 days at room temperature. GDH 5 air sampling tube and its associated determination method can be used for the collection and determination of eight kinds of CNBs in workplace air.