Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Practical Radiology ; (12): 1248-1251, 2017.
Article in Chinese | WPRIM | ID: wpr-608933

ABSTRACT

Objective To evaluate the clinical application of regulating bone removal ratio in dual-energy cerebral subtraction angiography.Methods A total of 45 patients who underwent two phases dual-energy CT angiography (CTA) were recruited and divided into several groups by the value of bone removal ratio,as follows: group A (Ratio=1.6), group B (Ratio=1.7), group C (Ratio=1.8) and group D (Ratio=1.9,default), as well as group E (100kV Neuro-DSA).The image quality of dual-energy CTA was evaluated by double blind method according to bone suppression and integrity of the vessel lumen (1-5 points, 1=poor, 5=excellent, 3-5=satisfactory).The bone removal ratio dependence of the image quality was analyzed using the self-control method.Moreover,the signal-to-noise ratio (SNR),contrast-to-noise ratio (CNR) and image scores were compared with the Neuro-DSA subtraction among these groups.Results The overall satisfaction of basis cranii images that were executed by dual-energy CTA with different bone removal ratios was listed as below: group A 73.33%, group B 91.11%, group C 78.52%, group D 70.37%.The satisfaction of siphon segment and petrous segment reached the maximum when the value of ratio was 1.7,and with significantly difference (P0.05).Conclusion With optimal bone removal ratio,the single enhanced dual-energy subtraction image quality with flash dual-source CT is consistent well with that of conventional 100 kV Neuro-DSA subtraction.Thus,this method is recommended in clinical emergency cerebrovascular examination for the improved image quality,which can compensate the shortage of vascular defect in basis cranill.

2.
Journal of Practical Radiology ; (12): 655-658, 2015.
Article in Chinese | WPRIM | ID: wpr-465691

ABSTRACT

Objective To assess the feasibility of double phase subtraction angiography with second generation (128-slice )dual-source CT in low dose Flash spiral scan mode for the evaluation of cerebral vessel,compared with dual-energy subtraction angiogra-phy.Methods 60 patients underwent double phrase CT angiography were divided into group A (n = 30,with Flash spiral scan mode),group B(n=30,with dual-energy scan mode).The signal-to-noise ratio(SNR),the contrast-to-noise ratio(CNR)and the av-erage radiation of double phrase subtraction images were measured in two groups,respectively.The double phase subtraction images quality were graded by 2 independent readers on a 5-point scale(5=excellent)in double-blind,according to various degrees of the re-sidual bones,the vessel displayed and luminal integrity,respectively.Differences between two groups were analyzed by Mann-whit-ney test and t test.Results The double phrase image SNR showed no difference to both two groups(P >0.05).The image CNR of arterial and venous phase in group A were higher than that of group B(40.89±8.89 and 40.27 ±9.90 in group A vs 35.28 ±8.43 and 34.89±8.66 in group B;P 0.05).The vessel image scores of arterial phase were higher in group A than that of group B(4.93±0.25 vs 3.87±0.97;P <0.05).Some internal carotid in the base of skull has not good luminal integrity in group B.The mean dose length product (DLP)in group A was lower than that of group B,with a 39 percent reduction[(226±5.69 )mGy/cm vs (368 ± 21.35 )mGy/cm,P < 0.05 ].Conclusion With the roughly similar image quality to dual-energy double phase subtraction angiography,the cerebral vessels can be assessed using dual-source CT subtraction angiography in Flash spiral scan mode and a lower radiation dose.

3.
Chinese Traditional Patent Medicine ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-573705

ABSTRACT

AIM: To develop a method to detemine pinostrobin in Weitengning Talets (Lindera reflexae Hemsl.) by HPLC. METHODS:A C_(18) column was used,methyl alcohol-water(80∶20) was used as a mobile phase and the wavelength of UV detector was set at 290 nm. RESULTS:The linearity of this method was good with the average recovery of 97.9%,RSD was 0.74%(n=5). CONCLUSION:The methed is simple,reliable,sensitivity,and with good reproducibility.It can be used in quality control of Weitengning Tablets.

SELECTION OF CITATIONS
SEARCH DETAIL