Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Tissue Engineering Research ; (53): 9337-9340, 2009.
Article in Chinese | WPRIM | ID: wpr-404803

ABSTRACT

OBJECTIVE: Sintering of porous coated anatomic porous layer bonding technology remains controversial because of poor understanding to its essence.ESSENCE: Sintering is a technology that the bonding temperature exceeds 5 ℃ or higher than the base-alloy solids temperature of 1 230 ℃, resulting in base-alloy produce a series of serious problems, such as grain boundary racks, handle broken and so on.HAZARDS: In sintering temperature, the low melting point eutectlc phase and the brittle metal compounds flow out of the grain boundary to bond the small metal balls and the handle, which greatly reduces the fatigue strength. The grain boundary cracks formed and expanded ultimately leading to handle broken.DISCUSSION: The cause of a handle broken is neither notch nor metallurgical defects but sintering process, because high sintering temperature results in grain-boundary lacunas.CONCLUSION: Sintering is not suitable for connecting the force components. High sintering temperature produces grain-boundary lacunas which can expand into cracks and ultimately result in handle broken under some condition.

2.
Chinese Journal of Tissue Engineering Research ; (53): 10141-10144, 2009.
Article in Chinese | WPRIM | ID: wpr-404618

ABSTRACT

INTRODUCTION: General joining techniques are at low level, which produces some potential problems in porous layer of porous coated anatomic (PCA).LIMITATIONS: The problems in general joining techniques are caused by limitations of each technique, which could not be solved using advanced measures.APPLICATION: The activated diffusion brazing technology is an effective way. Its many advanced processes can solve those potential problems.CONCLUSION: The stress-shielding problem caused by PCA porous layer can be solved by using small metal balls in the same diameter in combination with the advanced activated diffusion brazing technology. Moreover, the high performance brazing metals by activated diffusion brazing technology is harmless for humans.

3.
Chinese Journal of Tissue Engineering Research ; (53): 9523-9525, 2009.
Article in Chinese | WPRIM | ID: wpr-404616

ABSTRACT

A broken metal handle accompanied by femoral trunk fracture, which would shorten service life of handles. Therefore, it is necessary to judge whether the notch is the main reason for handle broken. Some literatures thought that the pores of sintered porous coated anatomic (PCA) porous layer produce the notch on the handle surface and the notches lead to the handle broken being incorrect. The Apex of the pore is taken for the bottom of the notch, expanding into a crack, and it should also not grow to the base-alloy, accordingly, the above conclusion is wrong. Some reports pointed out the notch, apex of the pore, will expand into the crack, but it is not associated with the broken handle. Under the sintering temperature, the grain boundary apertures be generated on the base metal surface, the aperture is expanded into the crack, which leads to handle broken in the forced area. However, neither theoretical basis, nor a case of corroboration, can prove exist of notch. Actually, the broken handle is caused by the sintering technology. The high temperature of sintering joining results in grain boundary aperture, when encounter the largest forced area and expand into crack, it will break the handle.

SELECTION OF CITATIONS
SEARCH DETAIL