Chinese Journal of Medical Instrumentation ; (6): 395-397, 2009.
Article in Chinese | WPRIM | ID: wpr-329294

ABSTRACT

The Portable dynamic state electrocardiogram collecting system is introduced by using TMS302VC5402, TLC320AD50C, liquid crystal display model, and so on. This dissertation describes the work principle of the system and uses the united algorithm based on wavelet to identify and locate the ECG characteristic waves. This system has as follows of advantages: big memory, low noise,high common mode rejection ratio, the low power consume,the long record time etc.


Subject(s)
Algorithms , Electrocardiography, Ambulatory , Equipment Design , Signal Processing, Computer-Assisted , Wavelet Analysis
2.
Chinese Journal of Medical Instrumentation ; (6): 257-264, 2008.
Article in Chinese | WPRIM | ID: wpr-309601

ABSTRACT

Based on the reconstruction of two-dimension phase space of time series of short ECG signals, the variation of the strange attractor geometry is described and two indices, VMI and VAI, are derived in this paper. The two indices can distinguish clearly the ECG signals of sinus rhythm, tachycardia and ventricular fibrillation. Stable results of VMI and VAI can be obtained by analyzing ECG signals of several seconds. They are expected to be used in the development of medical instruments for a fast realtime display of analysis results.


Subject(s)
Animals , Rabbits , Electrocardiography , Methods , Myocardial Infarction , Signal Processing, Computer-Assisted
3.
Ophthalmology in China ; (6)1993.
Article in Chinese | WPRIM | ID: wpr-679808

ABSTRACT

Objective To explore the agreement of anterior chamber angle examination by slit lamp optical coherence tomography (SL-OCT) and gonioscope.Design Case series.Participants Thirteen patients with primary glaucoma (26 eyes) and 8 normal persons(16 eyes).Methods Anterior chamber angle was measured with SL-OCT and gonioscope in turns for temporal,nasal,superior and inferior quadrant.Results of two methods were analyzed and the data were analyzed with Pearson correlation coefficient and Kappa value.Main Outcome Measures Anterior chamber angle.Results The Pearson correlation coefficient of the two methods was 0.86(P=0.00)and the Kappa value is 0.75 (P=0.00).The specificity and sensitivity of detecting occludable angle were 94.7% and 89.4%.Conclusions Anterior chamber angle examination with SL-OCT and gonioscope are well consistent.The specificity and sensitivity for SL-OCT in detecting occludable angle is satisfying.SL-OCT can be regard as an objective assistant method for the diagnosis of angle closure glaucoma.