Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Pathophysiology ; (12)2000.
Article in Chinese | WPRIM | ID: wpr-523815

ABSTRACT

AIM: To investigate the effects of angiotensin-converting enzyme inhibitors (ACEI), fosinopril, captopril and angiotensin II AT 1 antagonists, valsartan on tissue factor (TF) expression on monocytes induced by lipopolysaccharide (LPS). METHODS: Mononuclear leukocytes from normal delivered female umbilical veins were incubated with bacterial LPS in presence or absence of different ACE inhibitors .At the end of incubation, the cells were disrupted by 3 freeze-thaw cycles. TF procoagulant activity was assessed by a one-stage clotting assay. RT-PCR was used to check TF mRNA expression, and GAPDH mRNA was used for parallel assay. RESULTS and CONCLUSION: The results showed that increased expression of TF mRNA induced by LPS was inhibited by fosinopril, captopril and valsartan, respectively, and the procoagualant activity of monocytes was also reduced. [

2.
Chinese Journal of Interventional Cardiology ; (4)1996.
Article in Chinese | WPRIM | ID: wpr-585136

ABSTRACT

Objective To investigate the safety and efficacy of Left atrial linear ablation of paroxysmal atrial fibrillation guided by three-dimensional electroanatomical system. Methods 29 patients with paroxysmal atrial fibrillation in this study. A nonfluoroscopic mapping system was used to generate a 3D electroanatomic LA mapping, and all pulmonary vein ostia were marked under the help of pulmonary veins angiography on the 3D map. Radiofrequency (RF) energy was delivered to create continuous linear lesions encircling the pulmonary veins. It was delivered with a target temperature of 43℃, a maximal power limit of 30W and applied for ≥20 seconds until the maximal local electrogram amplitude decreased by ≥50%. The ablation was completed by finishing the circular line. Results The mean procedure duration was 180?18 minutes, with mean fluoroscopy time of 80?20 minutes. The average number of RF pulses was 120?15. After a follow-up of 6.0 months, 24 patients maintained sinus rhythm. 3 patients suffered from less frequent paroxysmal atrial fibrillation during the first 3.0 months after the ablation and remained Af free after 6 months. 1 patient had atrial fibrillation episodes and 1 patient had atrial fibrillation attacks unchanged. No pulmonary vein narrowing was observed. Conclusion Left atrial linear ablation of paroxysmal atrial fibrillation guided by three-dimensional electroanatomical system was safe and effective.

SELECTION OF CITATIONS
SEARCH DETAIL