Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add filters








Year range
1.
Chinese Journal of Anesthesiology ; (12): 195-198, 2022.
Article in Chinese | WPRIM | ID: wpr-933318

ABSTRACT

Objective:To evaluate the feasibility of measuring pulmonary venous blood flow spectrum by transesophageal ultrasound in assessing intraoperative left atrial pressure (LAP) in pediatric patients with complex congenital heart disease.Methods:Twenty-five pediatric patients with complex congenital heart disease of either sex, aged < 3 yr, of American Society of Anesthesiologists physical status Ⅲ or Ⅳ, with New York Heart Association class Ⅲ or Ⅳ, undergoing surgery with general anesthesia and requiring LAP monitoring during surgery, were selected.Transesophageal echocardiography was used to record the left pulmonary venous blood flow spectrum during surgery.S wave velocity (PV S), D wave velocity (PV D), AR wave velocity (PV AR), and deceleration time of pulmonary venous diastolic flow (DT D) were measured at 15 min after termination of CPB.The ratio of S wave peak velocity to D wave peak velocity (S/D ratio) was calculated.Measurement was carried out for 3 consecutive cardiac cycles, and the average value was calculated.The LAP was simultaneously measured through the left atrial piezometer.Pearson correlation analysis was performed between PV S, PV D, PV AR, DT D, S/D ratio and LAP. Results:PV S, PV D, PV AR and S/D ratio had no correlation with LAP ( r=-0.06, 0.21, 0.19, -0.38, respectively, P>0.05), while DT D was negatively correlated with LAP ( r=-0.84, P<0.05). Conclusions:DT D measured by transesophageal ultrasound can be used to evaluate intraoperative LAP in pediatric patients with complex congenital heart disease.

2.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 539-541, 2017.
Article in Chinese | WPRIM | ID: wpr-662831

ABSTRACT

Objective To explore the feasibility of hybrid procedure of percutaneous puncture for residual shunt after ventricular septal defect(VSD) repair.Methods From March 2015,we did percutaneous punctured transcatheter device closure of residual shunt after VSD repair for four patients.The patients included 2 males and 2 females with age from 4 years 9 months to 11 years 7 months and weight from 18 kg to44 kg.Four patients are diagnosed for4 years after VSD repair,3 years after tetralogy of Fallot (TOF),3 years after coarctation of aorta(CoA) combined with VSD,and 1 year after VSD repair,respectively.The withsize of residual shunt from 4.8 mm to 6.8 mm.Residual shunt are perimembranous,conoventricular and intracristal.Punctured directly through the right ventricular surface into the right ventricle in the 4-th or 5th intercostal space of the left sternal border.Next,extracted the guide wire after inserting a conveyor tube.Subsequently,7-10 mm VSD closure device were delivered via the conveyor tube.Results All the four operations were succeeded.A total of four closure devices were placed.Two of them are equilateral devices,and two are decentered devices,with size from 7mm to 9mm.Echocardiographyexamination revealed no significant pericardial effusion.Post-operative ultrasonic cardiogram showed the VSD closure device on site,with no pericardia1 effusion and no obvious morphological abnormalities of the valve.For one-year follow-up,the cardiac functionsof all patients were well.Conclusion Percutaneous punctured transcatheter device closure is a new,efficient and reliable method of treatment for children withresidual shunt after VSD repair.This method also can extend and offer a new avenue for valvular prosthesis and Perimembranous VSD.

3.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 539-541, 2017.
Article in Chinese | WPRIM | ID: wpr-660830

ABSTRACT

Objective To explore the feasibility of hybrid procedure of percutaneous puncture for residual shunt after ventricular septal defect(VSD) repair.Methods From March 2015,we did percutaneous punctured transcatheter device closure of residual shunt after VSD repair for four patients.The patients included 2 males and 2 females with age from 4 years 9 months to 11 years 7 months and weight from 18 kg to44 kg.Four patients are diagnosed for4 years after VSD repair,3 years after tetralogy of Fallot (TOF),3 years after coarctation of aorta(CoA) combined with VSD,and 1 year after VSD repair,respectively.The withsize of residual shunt from 4.8 mm to 6.8 mm.Residual shunt are perimembranous,conoventricular and intracristal.Punctured directly through the right ventricular surface into the right ventricle in the 4-th or 5th intercostal space of the left sternal border.Next,extracted the guide wire after inserting a conveyor tube.Subsequently,7-10 mm VSD closure device were delivered via the conveyor tube.Results All the four operations were succeeded.A total of four closure devices were placed.Two of them are equilateral devices,and two are decentered devices,with size from 7mm to 9mm.Echocardiographyexamination revealed no significant pericardial effusion.Post-operative ultrasonic cardiogram showed the VSD closure device on site,with no pericardia1 effusion and no obvious morphological abnormalities of the valve.For one-year follow-up,the cardiac functionsof all patients were well.Conclusion Percutaneous punctured transcatheter device closure is a new,efficient and reliable method of treatment for children withresidual shunt after VSD repair.This method also can extend and offer a new avenue for valvular prosthesis and Perimembranous VSD.

4.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 577-579, 2017.
Article in Chinese | WPRIM | ID: wpr-667363

ABSTRACT

Objective To explore the feasibility of percutaneous puncture for ventricular septal defect(VSD).Methods From March 2015,we did percutaneous punctured transcatheter device closure of VSD for 22 patients.The patients included 15 males and 7 females with age from 2 years 6 months to 11 years 7 months, weight from 13.5 kg to 44.0 kg.Among 22 pa-tients,6 were diagnosed with residual shunt after VSD repair, with size of residual shunt from 4.8 mm to 7.0 mm.Residual shunts are perimembranous, conoventricular and intracristal.The other 16 patients were diagnosed with isolated VSD,with de-fect size from 3.5 to 5.1 mm.For all patients,we punctured directly through the right ventricular surface into the right ventri-cle in the 3th or 4th intercostal space of the left sternal border.Next, we succeeded to extract the guide wire after inserting a conveyor tube for 21 patients.Subsequently,7-10 mm VSD closure device were delivered via the conveyor tube.Only one patient was changed to perform occlusion of VSD through chest small incision due to improper selection of punctured position. Results A total of 21 closure devices were placed for 21 patients.18 of them are equilateral device,and 3 are decentered de-vice,with size from 5 mm to 10 mm.There were small amount of pericardial effusion in 4 patients using TEE examination,and no future treat was performed after observation.For one-year follow-up, all patients have recovered very well.Conclusion Percutaneous punctured transcatheter device closure fits for treatment for children with residual shunt after VSD repair and isola-ted VSD.It has a good recent result.

5.
Chinese Journal of Ultrasonography ; (12): 789-792, 2015.
Article in Chinese | WPRIM | ID: wpr-482207

ABSTRACT

Objective To investigate the clinical value of ultrasonic diagnosis for neonatal annular pancreas,analyze the reasons of missed diagnosis and misdiagnosis,and improve diagnostic accuracy of ultrasonography for this disease.Methods Clinical data of 98 newborns with annular pancreas confirmed by gastrointestinal contrast and surgery were analyzed retrospectively.Preoperative ultrasonogram were compared with the result of gastrointestinal contrast and surgery.Ultrasound images failed to be correctly dignosed were further studied to summarize diagnostic points for this disease.Results Among the 98 cases, 75 were correctly diagnosed by ultrasound with a diagnostic accordance rate of 76.5%,1 8 were missed diagnosed and 5 were misdiagnosed with a total misdiagnosis rate of 23.5%.Ten cases associated with other congenital gastrointestinal tract anomalies were missed diagnosed due to ignoring scanning pancreas.Five cases were missed diagnosed due to obvious intestinal cavity flatulence.Three cases were missed diagnosed due to lack of awareness of the disease.Five cases were misdiagnosed for duodenal stenosis or duodenal atresia.Conclusions Ultrasound has important diagnostic value for neonatal annular pancreas,providing the dignostic evidences for clinical treatment.Thus it can be used as the preferred auxiliary examination of the disease.Since annular pancreas is often accompanied by other gastrointestinal malformations and can be interfered by abdominal gas,missed diagnosis and misdiagnosis occurred easily.To improve the accuracy of ultrasonic diagnosis,all causes of neonatal gastrointestinal tract obstructions should be considered during the examination.

6.
Chinese Journal of Ultrasonography ; (12): 747-750, 2012.
Article in Chinese | WPRIM | ID: wpr-419374

ABSTRACT

Objective To evaluate the clinical outcome of transesophageal echocardiography(TEE) in guiding and monitoring min-invasive transthoracic hybrid procedure for intracristal ventricular septal defects (VSD) using eccentric occluders.Methods 13 patients with intacristal VSD successfully underwent the min-invasive hybrid procedure using eccentric occluders were analyzed retrospectively.They were all carefully examined by transthoracic echocardiography (TTE) preoperatively and were diagnosed as intracristal VSD.There were no obvious aortic valve prolapse and no severe regurgitation.The entire process was guided and monitored by TEE.The condition of VSD occlusion was assessed by immediate postoperative TEE.Results All cases were occluded successfully.The results of postoperative TEE showed that the occluder was coincided closely with the edge of VSD,no aortic valve regurgitation worsen.2 had tiny residual left-to-right shunt (<1.5 mm),which disappeared 1 and 3 months respectively after operation.No occluder dislocated followed-up at 6 months to 2 years postoperatively,and no major complications occurred.Conclusions The min-invasive hybrid procedure for intracristal VSD using eccentric occluders guided and monitored by TEE is easy to manipulate,which is safe,less invasive,and has excellent early-term results.

7.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 708-711, 2012.
Article in Chinese | WPRIM | ID: wpr-429391

ABSTRACT

Objective To sum up the clinical information and outcomes of one-stage surgical repairs for interrupted aortic arch (IAA) associated with cardiac defects through median stemotomy in infant.Methods From August 2005 to January 2012,23 IAA patients,aged 18 days to 3 years [mean age (8.61 ± 11.81) months],body weight 3.3-13.0 kg [mean (6.61 ± 3.26) kg] were reviewed underwent one-stage repair.There were 12 male and 11 female.The anatomic subtype ineluded type A 20 (87.0%),type B 3 (13.0%),and no type C in the records.All cases included ventricular septal defect and patent ductus artefious,some also with artirical-pulmonary window,aterical septal defect,bicuspid or unicuspid aortic valve,and subvalvular aortic stenosis.Diagnosis was determined in of the patients and suspected in by echocardiography.Also,64 layers helico-CT was employed to make a definite diagnosis for 18 patients and cardiac catheterization was used for 4 patients.All patients with cardiac anomalies underwent one-stage repair through median sternotomy.The aortic continuity was reestablished by anastomosis between the descending aortic segment and aortic arch.Results In all 23 cases,21 were successful.There was 2 (8.69%) postoperative death:one was due to surgical hemorrhage and severe low cardiac output during perioperative stage and the other was 2-month old due to crisis of pulmonary hypertension.CPB time was ranged from 53-215 min [(129.76 ± 38.98) min],and aortic crossclamp time was 34-125 min[(74.47 ± 24.30) min].The length of stay in ICU postoperatively was 96h averagely.The postoperative complications included severe low cardiac output syndrome in 3 patients,hypoxemia in 13,pneumonia in 7,and supraventricular tachycardia in 12.21 patients were followed up from 2 months to 6 years and were in good condition without recoactation.Conclusion The outcomes of early and medium term for one-stage repair of IAA and associated cardiac anomalies through median stemotomy is excellent.Technique of extended anastomosis between the descending aortic segment and aortic arch may reduce the incidence of recoarctation.It is simplified the procedure and improved life quality of patients.

8.
Chinese Journal of Ultrasonography ; (12): 189-192, 2012.
Article in Chinese | WPRIM | ID: wpr-425096

ABSTRACT

Objective To discuss the application value of transesophageal echocardiography (TEE) in occluding procedure with cardiopulmonary bypass (CPB) for children muscular ventricular septal defects (mVSD).Methods Forty-nine mVSD patients for occluding procedure with CPB were performed guided and monitored by TEE,9 cases were simple mVSD,40 were mVSD combined with other cardiac malformations.The location,size,number,scope and the surrounding anatomy of mVSD were carefully observed before going into cardiac arrest,preparing the operator to choose appropriate occluder devices.The procedure was evaluated after the recovery of heart beat using TEE.Results In all of the 49 patients underwent occluding procedure,44 cases were implanted into one occluder,5 implanted into two occluders.The results of TEE after operation showed that the positions of all occluders were not shifted,2 had trace residual shunt,there were no complications worsening,such as mitral and aortic regurgitation,etc.One patient abandoned treatment for serious infection,the other patients' occluders were all in normal position followed up at 6 months to 2 years after operation,there were no tiny residual shunt and valves regurgitation except 1 patient.Conclusions The technique that TEE guiding and monitoring in occluding procedure with cardiopulmonary bypass for children muscular ventricular septal defects can shorten the time of cardiopulmonary bypass,significantly reducing complications and risks of the surgery,improving the successful rate.

9.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 264-266,270, 2011.
Article in Chinese | WPRIM | ID: wpr-597831

ABSTRACT

Objective To summarize the technique and clinical experience of hybrid procedure under cardiopulmonary bypass (CPB) in children with muscular ventricular septal defect (mVSD). Methods From January 2006 to June 2010, 45 cases of mVSD underwent hybrid procedure with CPB. mVSDs were closed with devices under direct vision in 45 cases. Of them, there were 20 males and 25 females. They ranged from 52 days to 12 years [mean (2.05 ±2.48) year] in age and from 3 to 30 kg [(11.93 ±7.70)kg] in body weight. Preoperatively, most of children were highly susceptible to respiratory tract infections. The hybrid approach was used in all patients with CPB under the guidance of transesophageal echocardiography (TEE). The diameter of mVSDs ranged from 2 to 7 mm under TEE. Of 45 cases, 40 patients had increased rates of pulmonary blood flow. 29 patients had left axis deviation and 12 cases had sinus arrhythmia on electrocardiography (ECG). 19 had other congenital heart lesions, including transposition of great arteries in 1 case, tetralogy of Fallot in 2, pulmonary artery stenosis in 3, patent ductus arteriosus in 6, atrial septal defects in 6) and aorta coactation in 1. The quantity of VSDs were from 1 to 7 (single, in 7; two, in 24 case; three, in 8 case; four, in 5 case and seven, in lease. 37 patients were combined with pulmonary hypertension in our cohort. 38 patients with another large VSD and 19 with other congenital heart lesions were required surgical repair at sometime. Results The hybrid procedures were undertaken in all 45 cases of this cohort. All cases were successful and no deaths occurred during operation. A total of 48 devices were implanted in 45 patients, including single devices in 42 cases (device size ranged from 4 to 10 mm) and two devices in 3 cases (device size ranged from 4 -7 mm). The average time on CPB was (58.28 ±20.70) min , while aortic crossclamp time was(34. 94 ± 14.75) min. In addition, the time on mechanical ventilation postoperatively ranged from 2 hours to 6 days. Compared to the older children, 20 infante aged less than 8 monhad a significant difference in cardiac function in the early postoperative period. One infant was given up treatment because of serious infection. Anather cases recovered with the use of supportive treatment, such as using vasoactive agents, digoxin, inhaling nitric oxide, diuresis, and so on. The enteric-coated aspirin was given at dose of 5 mg ? kg -1. day -1 for a period of 3 to 6 months as usual postoperatively. All patients attended follow-up at 1 week, 1 month, 3 months, 6 months, 1 year and 2 years post-procedure. No major complications were encountered during this period. All cases were no instance of migration of any of the devices, residual shunt, aortic regurgitation, atrioventricular valve dysfunction, Ⅲo atrial-ventricular conduction block, new arrhythmia, and so on. There are no death in long-term follow-up. Conclusion Hybrid procedure is safe and effective for the closure of congenital heart defects in children.

10.
Journal of Interventional Radiology ; (12): 177-180, 2010.
Article in Chinese | WPRIM | ID: wpr-401204

ABSTRACT

Objective To assess the respective value and limitation of cardioangiography and ultrasonography in interventional therapy for congenital heart disease in children,and to discuss the clinical significance of the combined use of both examinations. Methods A total of 162 children with congenital heart disease,screened by ultrasonography,were enrolled in this study.The disorders included VSD(n=50),PDA(n=96)and PS(n=16).Before the interventional therapy all the cases accepted cardioangiography and ultrasonography examinations,and the diameter of the abnormal passage was measured.The difference in the diameter between two examinations was compared and statistically analyzed by using paired t test.All the cases accepted both examinations after the interventional therapy to check the location of the occluder and the result of balloon dilatation.Results Both cardiovascular angiography and ultrasonography could make a definite diagnosis of congenital bean disease in children,and could well display the location and shape of the abnormalities.The diameter of VSD(n=50)measured by cardioangiography and ultrasonography was(4.93±2.73)mm and(5.66±2.77)mm respectively,with no significant statistical difference existing between two methods(P>0.05).The diameter at the narrowest site of PDA(n=96)measured by cardioangiography and ultrasonography was(3.22±1.45)mm and(3.96±1.42)mm respectively,with a significant difference existing between two methods(P<0.05).In 16 PS cases,the diameter of valvular ring determined on cardioangiogram and on ultrasonogram wag(16.16±4.26)mm and(17.94±5.50)mm respectively,with no significant difference between two groups(P>0.05).During the operation of VSD,the monitoring ultrasonography revealed that the valvular opening and closing was interfered by the occluder in 9 cases,so the occluder was re-adjusted till it was fixed to proper position. After the interventional therapy for VSD and PDA,cardioangiography detected a small residual shunt in 7 cases,which completely disappeared 24 hours later on ultrasonography.After balloon dilation in all 16 children with PS the right ventricle-pulmonary artery pressure difference was reduced by more than 50%and the pressure figure reached the standard of clinical Cure.The interventional procedure was successfully completed in all patients except for three cases. Conclusion In treating children of congenital heart disease with interventional procedures,the determination of the lesion's diameter and the selection of the occluder should be based on cardioangiographic measurement,although ultrasonography is more helpful in making preoperative screening and postoperative evaluation.

SELECTION OF CITATIONS
SEARCH DETAIL