Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Acta Pharmaceutica Sinica ; (12): 1029-33, 2014.
Article in Chinese | WPRIM | ID: wpr-448688

ABSTRACT

The paper reported an investigation of the pharmacokinetics of SN-38 (7-ethyl-10-hydroxy-camptothecin) in rats and the tissue distribution in mice after injection of irinotecan hydrochloride nanoparticles (CPT-11) via tail veins. An LC-MS/MS method was established to determine the concentrations of SN-38 in whole blood of rats and in different tissues of mice. The pharmacokinetics and tissue distribution of SN-38 were compared after the intravenous injection of CPT-11 NPs and CPT-11 solution. Compared with irinotecan solution, the elimination half-life of SN-38 was prolonged from 2.17 h to 2.67 h after the intravenous injection of CPT-11 NPs, but its AUC had little change. After the injection of CPT-11 NPs in mice, over time, the concentrations of CPT-11-metabolized SN-38 in CPT-11 NPs were significantly higher in the whole blood, colon and lungs than those in CPT-11 solution, followed by in the spleen and liver, but those in the heart and brain had no change. However, the amount of SN-38 in the kidneys was reduced with time. CPT-11 NPs could prolong SN-38's (one of its metabolites) blood circulation time in rats and significantly increased the concentration of CPT-11-metabolized SN-38 in the whole blood, colon and lungs of mice. CPT-11 NPs made SN-38 efficiently target-bind to the colon and lungs of mice.

2.
Acta Pharmaceutica Sinica ; (12): 741-5, 2013.
Article in Chinese | WPRIM | ID: wpr-445645

ABSTRACT

The object of this study is to investigate the pharmacokinetic interaction of pioglitazone hydrochloride and atorvastatin calcium in healthy adult Beagle dogs following single and multiple oral dose administration. A randomized, cross-over study was conducted with nine healthy adult Beagle dogs assigned to three groups. Each group was arranged to take atorvastatin calcium (A), pioglitazone hydrochloride (B), atorvastatin calcium and pioglitazone hydrochloride (C) orally in the first period, to take B, C, A in the second period, and to take C, A, B in the third period for 6 days respectively. The blood samples were collected at the first and the sixth day after the administration, plasma drug concentrations were determined by LC-MS/MS, a one-week wash-out period was needed between each period. The pharmacokinetic parameters of drug combination group and the drug alone group were calculated by statistical moment method, calculation of C(max) and AUC(0-t) was done by using 90% confidence interval method of the bioequivalence and bioavailability degree module DAS 3.2.1 software statistics. Compared with the separate administration, the main pharmacokinetic parameters (C(max) and AUC(0-t)) of joint use of pioglitazone hydrochloride and atorvastatin calcium within 90% confidence intervals for bioequivalence statistics were unqualified, the mean t(max) with standard deviation used paired Wilcoxon test resulted P > 0.05. There was no significant difference within t1/2, CL(int), MRT, V/F. Pioglitazone hydrochloride and atorvastatin calcium had pharmacokinetic interaction in healthy adult Beagle dogs.

3.
Chinese Journal of Trauma ; (12): 128-131, 2012.
Article in Chinese | WPRIM | ID: wpr-424499

ABSTRACT

ObjectiveTo study the clinical effect of the proximal femoral anatomical locking plate in the treatment of ipsilateral femoral shaft and neck fractures.Methods A retrospective study was done on 10 patients with ipsilateral femoral shaft and neck fractures treated with proximal femoral anatomical locking plate in our hospital from February 2009 to February 2011.After treatment,the outcome was assessed regularly by fracture union as was seen on serial radiographs and clinical function was estimated by Friedman and Vyman System.ResultsAll patients were followed up for 6-24 months ( average 16 months).All the fractures were healed within 2.5-4 months (average 3 months) in the femoral shaft and within 4-9 months (average 6 months) in the neck,respectively.According to Friedman and Vyman System,the overall clinical result was good in eight patients and fair in two,with excellent rate of 80% (8/10).No osteonecrosis of the femoral head and fixation failure were observed during the followup. Conclusion Proximal femoral anatomical locking plate internal fixation is an effective treatment method for ipsilateral femoral shaft and neck fractures.

SELECTION OF CITATIONS
SEARCH DETAIL