1.
Chinese Journal of Orthopaedics ; (12): 1762-1769, 2021.
Article in Chinese | WPRIM | ID: wpr-910770

ABSTRACT

Objective:To evaluate the follow-up clinical results of W-shaped acetabular angular plate for the treatment of acetabular posterior wall fractures through a direct posterior approach (DPA).Methods:Fifteen cases (10 males and 5 females, average aged 42.1±10.0 years) were involved in this study, with acetabular posterior wall fractures treated by using the W-shaped acetabular angular plate through a DPA between March 2017 and June 2019. Nine patients with fractures were injured by traffic accidents and the other 6 cases by falling. Based on the three-column classification for acetabular fractures, all of the cases belonged to posterior wall fractures (A2.1), which included 6 cases of simple fractures and 9 cases of comminuted fractures. The mean time interval between injury and surgery was 5.6±1.1 (range, 4-8) days. The DPA was adopted in all cases. The posterior wall fractures of the acetabulum were reduced and fixed with W-shaped acetabular angular plates. The reduction quality of the acetabulum was evaluated by X-ray and CT scan during follow-up visits according to the criteria proposed by Matta. The function of the hip joint was assessed by the Merle d'Aubigné-Posteal score modified by Matta.Results:The length of the surgical incision was 9.5±1.1 (range, 8-12) cm. The operation time was 45.3±10.1 (range, 35-75) mins. The amount of intraoperative blood loss was 248.0±94.7 (range, 100-380) ml. All the patients who were followed up for 20.5±6.3 (range, 16-38) months. All cases were evaluated according to Matta's reduction quality criteria, the satisfactory ratio of reduction was 100%. Among cases, 10 cases were matched the anatomic reduction, and the other 5 cases have belonged to satisfy. All cases of fractures had healed (the mean of healing time was 9.4±1.3 (range, 8-12 weeks). At the final follow-up visit, the mean of modified Merle d'Aubigne-Postel score was 16.9±1.6 (range, 13-18). Excellent clinical outcomes were obtained in 10 cases, good in 3 cases, and fair in 2 cases. One case had deep venous thrombosis of the lower extremities. The clots disappeared after anticoagulation treatment. One case had the heterotopic ossification, Brooker grade I, without any special treatment due to not affecting the hip joint activity in the follow-up visits. One patient had incision fat liquefaction and the wound healed after intensive dressing change. No internal fixation loosening or losing of fracture reduction was found at the follow-up visits.Conclusion:This study shows that using W-shaped acetabular angular plate for the treatment of acetabular posterior wall fractures through the DPA could obtain early satisfactory clinical outcomes.

2.
Chinese Journal of Orthopaedics ; (12): 1426-1433, 2021.
Article in Chinese | WPRIM | ID: wpr-910732

ABSTRACT

Objective:To investigate the surgical technique and the clinical effects of direct posterior approach (DPA) with the fixation of percutaneous tunnel screw and plate for acetabular posterior comminuted fractures.Methods:Thirty-six cases with acetabular posterior comminuted fractures treated by this technique from January 2016 to July 2020 were retrospectively analyzed in this study. There were 28 males and 8 female, aged 42.0±12.1 (range 19-64) years. According to Letournel-Judet classification, there were 28 cases of transverse associated with posterior wall fractures, 6 cases of posterior column with posterior wall fractures and 2 cases of T shape with posterior wall fractures. DPA was adopted in prone position. The anterior and posterior column fractures of the acetabulum were reduced under direct vision and then fixed with percutaneous tunnel screw. Further, the posterior wall fractures of the acetabulum were reduced and fixed with plate and screws. The operation duration, intraoperative blood loss, incision length, fracture union time, fracture reduction quality, postoperative complications and hip function were recorded.Results:The incision was 9.8±1.2 (range 8-12) cm. The operation duration was 102.9±21.4 (range 65-145) min. Intraoperative bleeding was 214.0±116.9 (range 100-640) ml. Postoperative X-ray and CT examinations showed perfect reduction. All the patients were followed up for 20.9±9.2 (range 10-38) months. The fracture healing time was 4.6±1.0 (range 3-6) months. There was no patient with damaged superior gluteal nerve and blood vessel. There were 2 cases of femoral head cystic changes without pain in walking, 1 case of postoperative infection and bacteremia who was cured at 1 month after debridement and anti-infection treatment, 1 case of sciatic nerve injury but recovered at 3 months after operation, and 1 case of heterotopic ossification at 3 months after surgery without affecting hip motion. According to the Matta's criteria, the reduction quality of the acetabular fracture was rated as excellent in 28 cases, good in 6 cases, fair in 2 cases. According to the modified Merle D'Aubigné and Postel scoring system, hip joint function was excellent in 24 cases, good in 10 cases and fair in 2 cases.Conclusion:DPA approach can directly reduce acetabular posterior comminuted fractures through a minimal incision. Combined with the technique of percutaneous tunnel screw, it displays great advantages of less trauma and with good clinical effects.

3.
Chinese Journal of Applied Clinical Pediatrics ; (24): 1433-1436, 2019.
Article in Chinese | WPRIM | ID: wpr-802949

ABSTRACT

Epilepsy mostly starts in childhood and can cause severe mental disorders.Treatment with antiepileptic drugs is effective in most patients, but 20%-30% of the patients continue to have uncontrolled seizures despite medical therapy, these are called drug-resistant epilepsy and need surgical treatment.Critical to discussion of surgical therapy are detailed presurgical evaluation and the lateralization and localization of epileptogenic zone.With deepening of the knowledge of epilepsy and progress of imaging technology, the evaluation of epilepsy surgery is changing gradually.Now, some methods and advances of surgical evaluation for children with drug-resistant epilepsy are reviewed.