Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Arq. bras. oftalmol ; 79(4): 255-257, July-Aug. 2016. graf
Article in English | LILACS | ID: lil-794585

ABSTRACT

ABSTRACT A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL) because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification.


RESUMO Uma paciente de 51 anos foi submetida à vitrectomia posterior com injeção de gás perfluoropropano, facoemulsificação e implante de lente intraocular (LIO) acrílica hidrofílica Oft cryl® devido a descolamento traumático da retina e catarata. No primeiro dia pós-operatório, o gás estava ocupando a câmara anterior pois a paciente não manteve o decúbito ventral restrito, tendo sido absorvido ao longo de uma semana. Oito meses depois, a paciente retornou com baixa da acuidade visual. Ao exame foi evidenciado opacificação da lente intraocular. A lente foi explantada e submetida à análise macroscópica e sob microscopia óptica. Também, foi corada pelo método de vermelho de alizarina, que identifica cálcio. A análise sob microscopia óptica evidenciou depósitos granulares, densamente distribuídos em padrão circular na parte central da óptica da lente intraocular, que coraram positivo para cálcio. Esse é o primeiro relato de opacificação dessa lente hidrofílica. Os cirurgiões devem estar atentos para esta potencial complicação pós-operatória.


Subject(s)
Humans , Female , Middle Aged , Postoperative Complications/etiology , Prosthesis Failure/etiology , Lens Implantation, Intraocular/adverse effects , Lenses, Intraocular/adverse effects , Vitrectomy , Phacoemulsification , Device Removal , Fluorocarbons , Microscopy/methods
2.
Rev. bras. oftalmol ; 71(3): 149-154, maio-jun. 2012. ilus
Article in English | LILACS | ID: lil-643911

ABSTRACT

Five cases of intraocular lens (IOL) opacification in patients implanted with the Mediphacos Ioflex® IOL are described. Clinical data in each case was obtained from the patient's medical record. The five explanted IOLs underwent gross and light microscopic analysis. Selected lenses were processed for further evaluation and multiple sagittal cuts were stained with the alizarin red and von Kossa methods. Light microscope analysis confirmed the presence of deposits on and within the lens, which stained positive for calcium. The reason why calcification has occurred in these cases remains unclear, but surgeons should be aware of this potential late postoperative complication.


Cinco casos de opacificação de lente intraocular (LIO) em pacientes implantados com a LIO Ioflex® da Mediphacos são descritos. Os dados clínicos dos pacientes foram obtidos a partir dos prontuários médicos. As cinco LIOs explantadas foram enviadas para análise macroscópica e sob microscopia óptica. Algumas lentes foram processadas para análise adicional e múltiplos cortes sagitais foram corados pelos métodos de vermelho de alizarina e von Kossa. A análise sob microscopia óptica confirmou a presença de depósitos na superfície e no corpo da lente, que coraram positivamente para cálcio. A razão pela qual a calcificação ocorreu nestes casos permanece obscura. Entretanto, cirurgiões devem estar atentos para esta potencial complicação tardia.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Acrylic Resins/adverse effects , Prosthesis Failure , Calcinosis/diagnosis , Calcinosis/etiology , Lenses, Intraocular/adverse effects , Microscopy , Postoperative Complications , Reoperation , Visual Acuity , Medical Records , Calcium/analysis , Phacoemulsification , Lens Implantation, Intraocular , Device Removal
3.
Indian J Ophthalmol ; 2004 Jun; 52(2): 99-112
Article in English | IMSEAR | ID: sea-72067

ABSTRACT

Posterior capsule opacification (PCO, secondary cataract, after cataract) is a nagging postsurgical complication following extracapsular cataract surgery (ECCE) and intraocular lens (IOL) implantation. PCO should be eliminated since it has deleterious sequelae and Neodynium: Yttrium Aluminium Garnet (Nd: YAG) laser treatment often is an unnecessary financial burden on the health care system. PCO following cataract surgery could be a major problem, since patient follow-up is difficult and the Nd:YAG laser is not always available. Advances in surgical techniques, IOL designs/biomaterials have been instrumental in bringing about a gradual and unnoticed decrease in the incidence of PCO. We strongly believe that the overall incidence of PCO and hence the incidence of Nd:YAG laser posterior capsulotomy is now rapidly decreasing - from 50% in the 1980s and early 1990s to less than 10% currently. Superior tools, surgical procedures, skills and appropriate IOL designs have all helped to significantly reduce this complication. In this article, we review the aetio pathogenesis, experimental and clinical studies and propose surgical and implant-related factors for PCO prevention. Careful application and utilisation of these factors by surgeons could lead to a significant reduction is secondary cataract, the second most common cause of visual loss worldwide.


Subject(s)
Animals , Cataract/etiology , Cataract Extraction , Humans , Laser Therapy , Lens Capsule, Crystalline/pathology , Lens Implantation, Intraocular , Postoperative Complications , Risk Factors
4.
Indian J Ophthalmol ; 2003 Sep; 51(3): 211-6
Article in English | IMSEAR | ID: sea-70740

ABSTRACT

Cataract surgery with intraocular lens (IOL) implantation has become the most common and most successful of all operations in medicine. Sir Harold Ridley's first cataract extraction with implantation of an IOL marked the beginning of a major change in the practice of ophthalmology. Millions of patients worldwide have benefited from Sir Ridley's invention, and are likely to continue to derive benefit from this device. However, the development of the IOL was not without its share of ups and downs. Sir Harold Ridley, the inventor of IOL, died at the age of 94, on 25 May 2001, and ophthalmology lost one of its greatest and most influential practitioners. We are happy that he lived to enjoy the fruits of his labour--to see the amazing improvements and the expansive growth that evolved in the cataract-IOL technique, from early and unsatisfactory operations in previous decades, to the superb results attainable today. The invention of the IOL has not been just the addition of one new form of treatment, but rather, Sir Harold's tiny disc-shaped sliver of plastic has changed the world so that our patients may better see it. This article presents a brief biographical sketch of Sir Harold and lists his major inventions and contributions to ophthalmology.


Subject(s)
Cataract Extraction/history , England , History, 20th Century , History, 21st Century , Humans , Lens Implantation, Intraocular/history , Lenses, Intraocular/history , Ophthalmology/history
5.
Rev. bras. oftalmol ; 61(8): 581-587, ago. 2002. ilus
Article in Portuguese | LILACS | ID: lil-335149

ABSTRACT

Objetivo: Relatar um caso mostrando os resultados da análise patológica de uma lente intra-ocular (LIO) acrílica hidrofílica com elevado conteúdo de água, explantada devido à impregnação por azul de tripano. Local: Serviço de Oftalmologia do Hospital Geral da Piedade, Rio de Janeiro, RJ, Brasil; Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. Métodos: Neste caso uma LIO AcquaTM (Mediphacos, Belo Horizonte, MG) foi explantada no quadragésimo dia de pós-operatório devido à impregnação de azul de tripano utilizado para corar a cápsula anterior durante a facoemulsificação. A LIO foi enviada para realização de análise macro e microscópica no estado seco e após hidratação. Resultados: A análise revelou que a impregnação em azul mais densa ocorreu no componente óptico da LIO, especialmente na periferia óptica. A impregnação em azul não pôde ser removida após 24 horas de imersão da LIO em solução salina balanceada a 37° C. Conclusão: A LIO AcquaTM é implantada no estado seco e sua hidratação/expansão depende dos fluidos que estão dentro do saco capsular. O uso de corantes capsulares deve ser evitado se esta LIO vai ser implantada.


Subject(s)
Humans , Male , Lens Implantation, Intraocular , Trypan Blue , Aged, 80 and over , Outcome and Process Assessment, Health Care , Postoperative Complications
7.
Indian J Ophthalmol ; 2002 Mar; 50(1): 49-51
Article in English | IMSEAR | ID: sea-69544

ABSTRACT

We report the clinicopathological findings of a human pseudophakic globe obtained postmortem, containing both anterior and posterior chamber intraocular lens, a condition we termed "bipseudophakia".


Subject(s)
Aged , Aged, 80 and over , Anterior Chamber/pathology , Foreign-Body Migration/pathology , Humans , Lens Implantation, Intraocular , Lenses, Intraocular , Male , Phacoemulsification , Polymethyl Methacrylate , Pseudophakia/pathology
9.
Arq. bras. oftalmol ; 63(6): 487-93, nov.-dez. 2000. ilus, graf
Article in Portuguese | LILACS | ID: lil-287887

ABSTRACT

A presbiopia é um dos mais precoces sinais do envelhecimento natural e a fisiopatologia básica envolvida no seu desenvolvimento tem sido um tema de controvérsia durante séculos. Este artigo discute vários aspectos da presbiopia através de uma revisäo literária das alteraçöes que ocorrem no olho durante este processo, e que já foram descritas previamente por diversos autores.


Subject(s)
Humans , Accommodation, Ocular/physiology , Presbyopia/physiopathology , Eye , Eye/cytology , Lens, Crystalline , Lens, Crystalline/physiology
10.
Arq. bras. oftalmol ; 62(6): 705-11, nov.-dez. 1999. ilus
Article in Portuguese | LILACS | ID: lil-279954

ABSTRACT

Objetivo: Este estudo prospectivo compara as imagens de microscopia confocal do epitélio corneano do coelho e do homem, obtidas através de 2 objetivas com aberturas numéricas (AN) diferentes. Métodos: Dez olhos de coelhos foram enucleados e fixados através de um suporte pneumático para garantir o melhor desempenho de cada objetiva. Cinco pacientes normais foram selecionados após consentimento. Os olhos de coelhos e dos pacientes foram previamente examinados na lâmpada de fenda. O exame de microscopia confocal (Tomey, Erlangen-Tennenlohe, Alemanha) foi realizado com as objetivas achroplan 40x/AN = 63x/AN = 0,9 (Zeiss Oberkochen, Alemanha). Imagens selecionadas do epitélio corneano foram avaliadas qualitativamente com relaçäo ao tamanho, forma e refl tividade das células. Resultados: As células no epitélio superficial dos coelhos e dos pacientes, previamente à descamaçäo, tiveram uma refletividade maior que as células adjacentes. Este aspecto foi claramente observado somente com a objetiva 63x/AN = 0,9. As camadas basal e intermediária do epitélio em coelhos foram visualizadas somente através desta objetiva. Estas camadas nos pacientes tornaram-se mais nítidas com a objetiva de abertura numérica maior (63x/AN = 0,9). Conclusäo: Uma objetiva de abertura numérica elevada p oduz melhor resoluçäo dos cortes ópticos, facilitando a análise as camadas do epitélio no coelho e no homem


Subject(s)
Humans , Animals , Rabbits , Epithelium, Corneal , Microscopy, Confocal , Microscopy, Confocal/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL