Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 79
Filter
1.
Imaging Science in Dentistry ; : 257-263, 2023.
Article in English | WPRIM | ID: wpr-1000491

ABSTRACT

Fibrodysplasia ossificans progressiva is a rare hereditary disorder characterized by progressive heterotopic ossifica-tion in muscle and connective tissue, with few reported cases affecting the head and neck region. Although plain radiographic findings and computed tomography features have been well documented, limited reports exist onmagnetic resonance findings. This report presents 2 cases of fibrodysplasia ossificans progressiva, one with limited mouth opening due to heterotopic ossification of the lateral pterygoid muscle and the other with restricted neck movement due to heterotopic ossification of the platysma muscle. Clinical findings of restricted mouth opening or limited neck movement, along with radiological findings of associated heterotopic ossification, should prompt consideration of fibrodysplasia ossificans progressiva in the differential diagnosis. Dentists should be particularly vigilant with patients diagnosed with fibrodysplasia ossificans progressiva to avoid exposure to diagnostic biopsy andinvasive dental procedures.

2.
Imaging Science in Dentistry ; : 83-89, 2023.
Article in English | WPRIM | ID: wpr-1000474

ABSTRACT

Nodular fasciitis (NF) is a benign myofibroblastic proliferation that grows very rapidly, mimicking a sarcoma on imaging. It is treated by local excision, and recurrence has been reported in only a few cases, even when excised incompletely. The most prevalent diagnoses of temporomandibular joint (TMJ) masses include synovial chondromatosis, pigmented villonodular synovitis, and sarcomas. Cases of NF in the TMJ are extremely rare, and only 3 cases have been reported to date. Due to its destructive features and rarity, NF has often been misdiagnosed as a more aggressive lesion, which could expose patients to unnecessary and invasive treatment approaches beyond repair. This report presents a case of NF in the TMJ, focusing on various imaging features, along with a literature review aiming to determine the hallmark features of NF in the TMJ and highlight the diagnostic challenges.

3.
Imaging Science in Dentistry ; : 351-357, 2022.
Article in English | WPRIM | ID: wpr-966952

ABSTRACT

Purpose@#Convolutional neural networks (CNNs) have rapidly emerged as one of the most promising artificial intelligence methods in the field of medical and dental research. CNNs can provide an effective diagnostic methodology allowing for the detection of early-staged diseases. Therefore, this study aimed to evaluate the performance of a deep CNN algorithm for apical lesion segmentation from panoramic radiographs. @*Materials and Methods@#A total of 1000 panoramic images showing apical lesions were separated into training (n=800, 80%), validation (n=100, 10%), and test (n=100, 10%) datasets. The performance of identifying apical lesions was evaluated by calculating the precision, recall, and F1-score. @*Results@#In the test group of 180 apical lesions, 147 lesions were segmented from panoramic radiographs with an intersection over union (IoU) threshold of 0.3. The F1-score values, as a measure of performance, were 0.828, 0.815, and 0.742, respectively, with IoU thresholds of 0.3, 0.4, and 0.5. @*Conclusion@#This study showed the potential utility of a deep learning-guided approach for the segmentation of apical lesions. The deep CNN algorithm using U-Net demonstrated considerably high performance in detecting apical lesions.

4.
Imaging Science in Dentistry ; : 255-260, 2020.
Article | WPRIM | ID: wpr-835432

ABSTRACT

Acquired facial lipoatrophy is a rare disease with an unclear etiology and pathological pathway. The distinct causative factors of this disease have been not elucidated, but it is suspected to be associated with immune systemrelated diseases, most notably AIDS. Although the management of facial lipoatrophy is very important for patients’ social life and mental health, no treatment framework has been developed due to the unknown nature of the disease manifestation. The present case report was designed to provide sequential imaging to visualize the disease progression. The clinical backgrounds of the patients are also introduced, helping characterize this disease entity more clearly for maxillofacial specialists.

5.
Imaging Science in Dentistry ; : 177-177, 2019.
Article in English | WPRIM | ID: wpr-763987

ABSTRACT

The authors would like to correct an error in the publication of the original article. The number in the formula on page 256, right column, line 5 should be ‘346.0121’ instead of ‘3446.0121.’

6.
Imaging Science in Dentistry ; : 273-279, 2019.
Article in English | WPRIM | ID: wpr-785814

ABSTRACT

PURPOSE: This study was performed to investigate the effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield unit (HU) values of hydroxyapatite (HA) in virtual monochromatic images (VMIs) obtained with dual-energy computed tomography (DECT) (Siemens Healthineers, Erlangen, Germany).MATERIALS AND METHODS: A bone density calibration phantom with 3 HA inserts of different densities (CTWATER®; 0, 100, and 200 mg of HA/cm³) was scanned using a twin-beam DECT scanner at 120 kVp with tube rotation times of 0.5 and 1.0 seconds. The VMIs were reconstructed by changing the energy level (with options of 40 keV, 70 keV, and 140 keV). In order to investigate the impact of the reconstruction kernel, virtual monochromatic images were reconstructed after changing the kernel from body regular 40 (Br40) to head regular 40 (Hr40) in the reconstruction phase. The mean HU value was measured by placing a circular region of interests (ROIs) in the middle of each insert obtained from the VMIs. The HU values were compared with regard to energy level, reconstruction kernel, and tube rotation time.RESULTS: Hydroxyapatite density was strongly correlated with HU values (correlation coefficient=0.678, P<0.05). For the HA 100 and 200 inserts, HU decreased significantly at increased energy levels (correlation coefficient= −0.538, P<0.05) but increased by 70 HU when using Hr40 rather than Br40 (correlation coefficient=0.158, P<0.05). The tube rotation time did not significantly affect the HU (P>0.05).CONCLUSION: The HU values of hydroxyapatite were strongly correlated with hydroxyapatite density and energy level in VMIs obtained with DECT.


Subject(s)
Bone Density , Calibration , Durapatite , Head , Image Processing, Computer-Assisted
7.
Imaging Science in Dentistry ; : 287-294, 2019.
Article in English | WPRIM | ID: wpr-785812

ABSTRACT

PURPOSE: This study was performed to analyze the clinical and imaging features of contemporary osteomyelitis (OM) and to investigate differences in these features on panoramic radiography according to patients' history of use of medication affecting bone metabolism.MATERIALS AND METHODS: The records of 364 patients (241 female and 123 male, average age 66.8±14.9 years) with OM were retrospectively reviewed. Panoramic imaging features were analyzed and compared between patients with medication-related OM (m-OM) and those with conventional, medication-unrelated OM (c-OM).RESULTS: The age of onset of OM tended to be high, with the largest number of patients experiencing onset in their 70s. The 2 most frequent presumed causes were antiresorptive medication use (44.2%) and odontogenic origin (34.6%). On panoramic radiographs, a mix of osteolysis and sclerosis was the most common lesion pattern observed (68.6%). Sequestrum, extraction socket, and periosteal new bone formation were found in 143 (42.1%), 79 (23.2%), and 24 (7.1%) cases, respectively. The m-OM group exhibited sequestrum and extraction socket more frequently and displayed significantly higher mandibular cortical index values than the c-OM group.CONCLUSION: We observed some differences in imaging features as shown on panoramic radiography according to the history of antiresorptive medication use. This study may help elucidate the predictive imaging features of medication-related osteonecrosis of the jaw.


Subject(s)
Female , Humans , Male , Age of Onset , Jaw , Metabolism , Osteogenesis , Osteolysis , Osteomyelitis , Osteonecrosis , Radiography, Panoramic , Retrospective Studies , Sclerosis
8.
Imaging Science in Dentistry ; : 317-321, 2019.
Article in English | WPRIM | ID: wpr-785808

ABSTRACT

Steatocystoma multiplex is an uncommon benign skin disease, which typically manifests as numerous intradermal cysts that can be scattered anywhere on the body. Although usually asymptomatic, it can be significantly disfiguring. One type of steatocystoma multiplex is known to be associated with the autosomal dominant inheritance of a mutation in the gene coding for keratin 17 (KRT17). In such cases, it is often concurrent with other developmental abnormalities of the ectoderm-derived tissues, such as the nails, hair, and teeth. To the best of our knowledge, few cases have been reported of steatocystoma multiplex of the oral and maxillofacial region. This report describes a case of steatocystoma multiplex of both sides of the neck and multiple dental anomalies, with a focus on its clinical, radiological, and histopathological characteristics, as well as the possibility that the patient exhibited the familial type of this condition.


Subject(s)
Humans , Clinical Coding , Hair , Keratin-17 , Neck , Skin Diseases , Steatocystoma Multiplex , Tooth , Wills
9.
Imaging Science in Dentistry ; : 255-259, 2018.
Article in English | WPRIM | ID: wpr-740394

ABSTRACT

PURPOSE: This study proposes a new ball-type phantom for evaluation of the image layer of panoramic radiography. MATERIALS AND METHODS: The arch shape of an acrylic resin phantom was derived from average data on the lower dental arch in Korean adult males. Metal balls with a 2-mm diameter were placed along the center line of the phantom at a 4-mm mesiodistal interval. Additional metal balls were placed along the 22 arch-shaped lines that ran parallel to the center line at 2-mm buccolingual intervals. The height of each ball in the horizontal plane was spaced by 2.5 mm, and consequently, the balls appeared oblique when viewed from the side. The resulting phantom was named the Panorama phantom. The distortion rate of the balls in the acquired image was measured by automatically calculating the difference between the vertical and horizontal length using MATLAB®. Image layer boundaries were obtained by applying various distortion rate thresholds. RESULTS: Most areas containing metal balls (91.5%) were included in the image layer with a 50% distortion rate threshold. When a 5% distortion rate threshold was applied, the image layer was formed with a small buccolingual width along the arch-shaped center line. However, it was medially located in the temporomandibular joint region. CONCLUSION: The Panorama phantom could be used to evaluate the image layer of panoramic radiography, including all mesiodistal areas with large buccolingual width.


Subject(s)
Adult , Humans , Male , Dental Arch , Phantoms, Imaging , Radiography, Panoramic , Temporomandibular Joint
10.
Imaging Science in Dentistry ; : 97-101, 2018.
Article in English | WPRIM | ID: wpr-740374

ABSTRACT

PURPOSE: This study evaluated the radiopacity of contemporary luting cements using conventional and digital radiography. MATERIALS AND METHODS: Disc specimens (N=24, n=6 per group, ø7 mm×1 mm) were prepared using 4 resin-based luting cements (Duolink, Multilink N, Panavia F 2.0, and U-cem). The specimens were radiographed using films, a complementary metal oxide semiconductor (CMOS) sensor, and a photostimulable phosphor plate (PSP) with a 10-step aluminum step wedge (1 mm incremental steps) and a 1-mm-thick tooth cut. The settings were 70 kVp, 4 mA, and 30 cm, with an exposure time of 0.2 s for the films and 0.1 s for the CMOS sensor and PSP. The films were scanned using a scanner. The radiopacity of the luting cements and tooth was measured using a densitometer for the film and NIH ImageJ software for the images obtained from the CMOS sensor, PSP, and scanned films. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests. RESULTS: Multilink (3.44–4.33) showed the highest radiopacity, followed by U-cem (1.81–2.88), Panavia F 2.0 (1.51–2.69), and Duolink (1.48–2.59). The R² values of the optical density of the aluminum step wedge were 0.9923 for the films, 0.9989 for the PSP, 0.9986 for the scanned films, and 0.9266 for the CMOS sensor in the linear regression models. CONCLUSION: The radiopacities of the luting materials were greater than those of aluminum or dentin at the same thickness. PSP is recommended as a detector for radiopacity measurements because of its accuracy and convenience.


Subject(s)
Aluminum , Dental Enamel , Dental Materials , Dentin , Linear Models , Radiographic Image Enhancement , Radiography , Semiconductors , Tooth
11.
Journal of Periodontal & Implant Science ; : 84-91, 2018.
Article in English | WPRIM | ID: wpr-766055

ABSTRACT

PURPOSE: The purpose of this study was to visualize and identify peri-implant bone defects in optical coherence tomography (OCT) images and to obtain quantitative measurements of the defect depth. METHODS: Dehiscence defects were intentionally formed in porcine mandibles and implants were simultaneously placed without flap elevation. Only the threads of the fixture could be seen at the bone defect site in the OCT images, so the depth of the peri-implant bone defect could be measured through the length of the visible threads. To analyze the reliability of the OCT measurements, the flaps were elevated and the depth of the dehiscence defects was measured with a digital caliper. RESULTS: The average defect depth measured by a digital caliper was 4.88±1.28 mm, and the corresponding OCT measurement was 5.11±1.33 mm. Very thin bone areas that were sufficiently transparent in the coronal portion were penetrated by the optical beam in OCT imaging and regarded as bone loss. The intraclass correlation coefficient between the 2 methods was high, with a 95% confidence interval (CI) close to 1. In the Bland-Altman analysis, most measured values were within the threshold of the 95% CI, suggesting close agreement of the OCT measurements with the caliper measurements. CONCLUSIONS: OCT images can be used to visualize the peri-implant bone level and to identify bone defects. The potential of quantitative non-invasive measurements of the amount of bone loss was also confirmed.


Subject(s)
Dental Implants , Diagnosis , Intention , Mandible , Peri-Implantitis , Tomography, Optical Coherence
12.
The Journal of Advanced Prosthodontics ; : 58-64, 2018.
Article in English | WPRIM | ID: wpr-742009

ABSTRACT

PURPOSE: The aim of this study was to design an intraoral environment simulator and to assess the accuracy of two intraoral scanners using the simulator. MATERIALS AND METHODS: A box-shaped intraoral environment simulator was designed to simulate two specific intraoral environments. The cast was scanned 10 times by Identica Blue (MEDIT, Seoul, South Korea), TRIOS (3Shape, Copenhagen, Denmark), and CS3500 (Carestream Dental, Georgia, USA) scanners in the two simulated groups. The distances between the left and right canines (D3), first molars (D6), second molars (D7), and the left canine and left second molar (D37) were measured. The distance data were analyzed by the Kruskal-Wallis test. RESULTS: The differences in intraoral environments were not statistically significant (P>.05). Between intraoral scanners, statistically significant differences (P < .05) were revealed by the Kruskal-Wallis test with regard to D3 and D6. CONCLUSION: No difference due to the intraoral environment was revealed. The simulator will contribute to the higher accuracy of intraoral scanners in the future.


Subject(s)
Georgia , Molar , Seoul
13.
Imaging Science in Dentistry ; : 87-92, 2017.
Article in English | WPRIM | ID: wpr-191871

ABSTRACT

PURPOSE: The aim of this study was to determine whether the panoramic mandibular index (PMI) is useful for assessing bone mineral density. We also analyzed the potential correlations between PMI parameters and patient age. MATERIALS AND METHODS: Four observers measured the PMI of both sides of the mental foramen using a picture archiving and communication system and images in the Digital Imaging and Communications in Medicine format. They studied 300 panoramic radiographic images of patients belonging to the following age groups: 40–49 years, 50–59 years, 60–69 years, 70–79 years, and 80–89 years. The observers were allowed to zoom in or out and to adjust the contrast of the images. Further, they were instructed to record the reasons for any measurements that could not be made. Then, we conducted a reliability analysis of the measured PMI and assessed the correlations between different patient age groups and the 3 parameters used for determining the PMI from the available data. RESULTS: Among the 600 data items collected, 23 items were considered unmeasurable by at least 1 observer for the following 4 reasons: postoperative state, lesion, unidentified mental foramen, and alveolar bone loss. The intraobserver reproducibility of the measurable data was 0.611-0.752. The mandibular cortical width (MCW) decreased significantly as patient age increased. CONCLUSION: PMI had limited usability when the margin of the mental foramen was not clear. In contrast, MCW, a parameter used for determining the PMI, had fewer drawbacks than the PMI with respect to bone mineral density measurements and exhibited a significant correlation with patient age.


Subject(s)
Humans , Alveolar Bone Loss , Bone Density , Mandible , Radiography
14.
Imaging Science in Dentistry ; : 123-127, 2017.
Article in English | WPRIM | ID: wpr-191866

ABSTRACT

PURPOSE: Obstructive and inflammatory disease often occurs in the major salivary glands, and no predictive treatment has yet been developed for this condition. The aim of this report was to introduce an intraductal irrigation procedure and to illustrate its application to practical patient cases. MATERIALS AND METHODS: Two patients complaining of pain and swelling in the parotid gland during meals who underwent sialography were diagnosed as having sialodochitis with sialadenitis. Intraductal irrigation was then performed on the parotid gland on the side of the complaint. The irrigation procedure was conducted in the same manner as the sialography procedure, except that saline was used as the filling solution. Symptom severity was evaluated with a numerical rating scale (NRS) at the initial visit and a month after the irrigation. RESULTS: The initial NRS value of patient 1 was 10. The value decreased to 6 and then to 0 after 2 irrigation procedures. The NRS value of patient 2 regarding the symptoms involving the left parotid gland decreased from 4-5 to 1 after 4 irrigation procedures performed at 1-month intervals. CONCLUSION: Intraductal irrigation of the salivary gland may be a simple, safe, and effective treatment option for patients with obstructive and inflammatory disease of the salivary gland that is capable of resolving their symptoms.


Subject(s)
Humans , Meals , Parotid Gland , Salivary Glands , Sialadenitis , Sialography , Therapeutic Irrigation
15.
Imaging Science in Dentistry ; : 51-55, 2017.
Article in English | WPRIM | ID: wpr-147785

ABSTRACT

PURPOSE: This study was conducted to suggest the development of a learning management system for dental radiology education using the Modular Object-Oriented Dynamic Learning Environment (Moodle). MATERIALS AND METHODS: Moodle is a well-known and verified open-source software-learning management system (OSS-LMS). The Moodle software was installed on a server computer and customized for dental radiology education. The system was implemented for teaching undergraduate students to diagnose dental caries in panoramic images. Questions were chosen that could assess students' diagnosis ability. Students were given several questions corre-sponding to each of 100 panoramic images. RESULTS: The installation and customization of Moodle was feasible, cost-effective, and time-saving. By having students answer questions repeatedly, it was possible to train them to examine panoramic images sequentially and thoroughly. CONCLUSION: Based on its educational efficiency and efficacy, the adaptation of an OSS-LMS in dental school may be highly recommended. The system could be extended to continuing education for dentists. Further studies on the objective evaluation of knowledge acquisition and retention are needed.


Subject(s)
Humans , Computer-Assisted Instruction , Dental Caries , Dentists , Diagnosis , Education , Education, Continuing , Education, Dental , Learning , Schools, Dental
16.
Journal of Periodontal & Implant Science ; : 13-19, 2017.
Article in English | WPRIM | ID: wpr-160545

ABSTRACT

PURPOSE: The purpose of this study was to examine whether periodontal pocket could be satisfactorily visualized by optical coherence tomography (OCT) and to suggest quantitative methods for measuring periodontal pocket depth. METHODS: We acquired OCT images of periodontal pockets in a porcine model and determined the actual axial resolution for measuring the exact periodontal pocket depth using a calibration method. Quantitative measurements of periodontal pockets were performed by real axial resolution and compared with the results from manual periodontal probing. RESULTS: The average periodontal pocket depth measured by OCT was 3.10±0.15 mm, 4.11±0.17 mm, 5.09±0.17 mm, and 6.05±0.21 mm for each periodontal pocket model, respectively. These values were similar to those obtained by manual periodontal probing. CONCLUSIONS: OCT was able to visualize periodontal pockets and show attachment loss. By calculating the calibration factor to determine the accurate axial resolution, quantitative standards for measuring periodontal pocket depth can be established regardless of the position of periodontal pocket in the OCT image.


Subject(s)
Calibration , Gingiva , Image Interpretation, Computer-Assisted , Methods , Periodontal Pocket , Tomography, Optical Coherence
17.
Journal of Periodontal & Implant Science ; : 41-50, 2017.
Article in English | WPRIM | ID: wpr-160542

ABSTRACT

PURPOSE: The aims of the present study were to compare the image quality and visibility of tooth cracks between conventional methods and swept-source optical coherence tomography (SS-OCT) and to develop an automatic detection technique for tooth cracks by SS-OCT imaging. METHODS: We evaluated SS-OCT with a near-infrared wavelength centered at 1,310 nm over a spectral bandwidth of 100 nm at a rate of 50 kHz as a new diagnostic tool for the detection of tooth cracks. The reliability of the SS-OCT images was verified by comparing the crack lines with those detected using conventional methods. After performing preprocessing of the obtained SS-OCT images to emphasize cracks, an algorithm was developed and verified to detect tooth cracks automatically. RESULTS: The detection capability of SS-OCT was superior or comparable to that of trans-illumination, which did not discriminate among the cracks according to depth. Other conventional methods for the detection of tooth cracks did not sense initial cracks with a width of less than 100 μm. However, SS-OCT detected cracks of all sizes, ranging from craze lines to split teeth, and the crack lines were automatically detected in images using the Hough transform. CONCLUSIONS: We were able to distinguish structural cracks, craze lines, and split lines in tooth cracks using SS-OCT images, and to automatically detect the position of various cracks in the OCT images. Therefore, the detection capability of SS-OCT images provides a useful diagnostic tool for cracked tooth syndrome.


Subject(s)
Cracked Tooth Syndrome , Image Interpretation, Computer-Assisted , Tomography, Optical Coherence , Tooth Fractures , Tooth
18.
Imaging Science in Dentistry ; : 255-259, 2017.
Article in English | WPRIM | ID: wpr-10866

ABSTRACT

PURPOSE: Underlying bone sclerosis is frequently observed in clinical settings when oral squamous cell carcinoma (OSCC) invades the jaw bone. The aim of this study was to assess the prevalence and characteristics of underlying bone sclerosis in patients with OSCC. MATERIALS AND METHODS: We retrospectively reviewed the computed tomographic (CT) images of 131 patients who underwent mandibulectomy between January 2012 and December 2015 to treat OSCC. The presence, degree, and extent of underlying bone sclerosis were assessed on CT images and correlated with the following imaging patterns of bone invasion: cortical invasion, medullary invasion with a smooth margin, and medullary invasion with an irregular margin. The chi-square test was used to determine the relationships between the variables. RESULTS: The prevalence of underlying bone sclerosis on CT images was 70.1% (47 of 67). The prevalence was 85.7% (42 of 49) in patients with medullary invasion, but it was 27.8% (5 of 18) in patients with only cortical invasion, indicating a significant increase in the prevalence of underlying bone sclerosis in patients with medullary invasion (P < .05). Aggressive patterns of bone invasion were associated with increases in the degree and extent of the underlying bone sclerosis (P < .05). CONCLUSION: More than two-thirds of OSCC cases with bone invasion showed underlying bone sclerosis. On CT images, reactive sclerosis in the remaining margin of the alveolar bone should not be used as the primary means to differentiate periodontal inflammatory lesions from those resulting from OSCC.


Subject(s)
Humans , Carcinoma, Squamous Cell , Epithelial Cells , Jaw , Mandible , Prevalence , Retrospective Studies , Sclerosis , Tomography, X-Ray Computed
19.
Imaging Science in Dentistry ; : 103-108, 2016.
Article in English | WPRIM | ID: wpr-207634

ABSTRACT

PURPOSE: The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. MATERIALS AND METHODS: An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. RESULTS: The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. CONCLUSION: A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.


Subject(s)
Humans , Cone-Beam Computed Tomography , Dental Clinics , Dentists , Methods , Radiation Dosage , Radiation Monitoring , Radiography , Radiography, Dental
20.
Journal of Periodontal & Implant Science ; : 116-127, 2016.
Article in English | WPRIM | ID: wpr-84878

ABSTRACT

PURPOSE: The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. METHODS: We measured the impact response of a dental implant placed into swine bone specimens composed of only trabecular bone without the cortical bone layer using an inductive sensor. The peak frequency of the impact response spectrum was determined as an implant stability criterion (SPF). The 3D microstructural parameters were calculated from CT images of the bone specimens obtained using both micro-CT and CBCT. RESULTS: SPF had significant positive correlations with trabecular bone structural parameters (BV/TV, BV, BS, BSD, Tb.Th, Tb.N, FD, and BS/BV) (P<0.01) while SPF demonstrated significant negative correlations with other microstructural parameters (Tb.Sp, Tb.Pf, and SMI) using micro-CT and CBCT (P<0.01). CONCLUSIONS: There was an increase in implant stability prediction by combining BV/TV and SMI in the stepwise forward regression analysis. Bone with high volume density and low surface density shows high implant stability. Well-connected thick bone with small marrow spaces also shows high implant stability. The combination of bone density and architectural parameters measured using CBCT can predict the implant stability more accurately than the density alone in clinical diagnoses.


Subject(s)
Bone and Bones , Bone Density , Bone Marrow , Cone-Beam Computed Tomography , Dental Implants , Diagnosis , Swine , X-Ray Microtomography
SELECTION OF CITATIONS
SEARCH DETAIL