Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Language
Year range
1.
The Journal of Korean Academy of Prosthodontics ; : 153-159, 2023.
Article in English | WPRIM | ID: wpr-977357

ABSTRACT

Computer-aided design–computer-aided manufacturing technology has been widely used in the manufacture of fixed prostheses including implants, but in the case of removable dentures, the analog method is still being used due to the errors such as a lack of fusion and over-fusion in selective laser meting process. With the recent development of CAD software, virtual surveying and framework design are made possible, and the designed file can be manufactured by milling or 3D printing. It replace the analog method of waxing and denture curing process and also can reduce the production time and cost. Therefore, this case is reported because good clinical results were obtained by digitally surveying on CAD software to produce a surveyed metal restoration and framework on maxillary and mandibular removable dentures.

2.
The Journal of Korean Academy of Prosthodontics ; : 26-32, 2023.
Article in English | WPRIM | ID: wpr-968647

ABSTRACT

Dental trauma is common in active children and adolescents. Among them, in the case of ankylosis due to avulsion, diagnosis through clinical examination is important, and the treatment is important for esthetic prosthetic restoration after adulthood. This case is a case of esthetic prosthetic restoration of maxillary anterior teeth through decoronation and implant. After that, space was maintained for prosthetic restoration using a decoronated crown. After becoming an adult, precise implant placement and esthetic prosthetic restoration were possible using guide surgery. For soft tissue support, the temporary crown were replaced by changing the contours of the temporary crown, and the final esthetic prosthesis was fabricated by digital wax-up.

3.
Journal of Dental Rehabilitation and Applied Science ; : 242-248, 2022.
Article in English | WPRIM | ID: wpr-967152

ABSTRACT

Recently, through the development of CAD/CAM technology, it is also being used for fabricating dentures. Compared to conventional methods, when digital dentures are fabricated, the fabrication process is facilitated, and the number of visits to hospitals is reduced and errors are reduced. In this case, the vertical dimension was increased using a CAD program in a patient who needed vertical dimension recovery due to the use of old dentures, and the final denture was fabricated using a monolithic disc through the milling method. The centric relation was recorded using existing dentures, and using the information from the intraoral scan and the existing denture model scan, a trial denture was fabricated and delivered to the patient to evaluate the midline and occlusion. Based on the evaluation of the trial denture, the final denture was fabricated using a milling method and a monolithic disc, and the final denture showed satisfactory results functionally and aesthetically.

4.
Journal of Dental Rehabilitation and Applied Science ; : 249-256, 2022.
Article in English | WPRIM | ID: wpr-967151

ABSTRACT

The implant prosthesis of anterior maxilla requires careful consideration in planning. In order to satisfy both esthetic and functional needs of a patient, fusion of intra-oral scan in Cone-beam computed tomography (CBCT) and facial scan can be considered. Bony structures and soft tissues captured in CBCT and occlusal surfaces of intra oral scan were incorporated into personal characteristics from facial scan. The patient had insufficient buccal bone on maxillary anterior area. The maxillary implants could not be placed on the most ideal position. However, the “top down” approach completed by computer-generated arranging of teeth in implant planning and surgery with surgical guide resulted in esthetically and functionally satisfying result regardless of the limitation. Careful diagnosis with digital technique and the usage of surgical guide resulted in successful surgery and esthetic restoration. The temporary fixed prostheses were designed, restored and evaluated. The patient was not satisfied with the first design of temporary prosthesis, which showed uneven space distribution between teeth due to the position of maxillary implant. The design was modified by changing proximal emergence contours and line angle to alter the perceived since of incisors. The patient was satisfied with the new design of provisional restoration. A digital occlusion analyzer (Arcus Digma II, KaVo, Leutkirch, Germany) was used to measure inherent condylar guidance and anterior guidance of a patient to provide a definitive prosthesis.

5.
The Journal of Korean Academy of Prosthodontics ; : 459-468, 2021.
Article in English | WPRIM | ID: wpr-918864

ABSTRACT

In patients with myasthenia gravis, it is difficult to manufacture and maintain dentures because the muscles and nervous system in the oral cavity are not properly adjusted. In addition, excessively extended or thick dentures may cause muscle weakness by stimulating the muscles, so dentures should be manufactured in consideration of this. In this case, a denture was fabricated using the closed mouth technique in a patient with myasthenia gravis with mouth opening limitation. Using the closed mouth technique, the patient’s masticatory pressure and muscle movements were reproduced and denture with good retention were manufactured.

6.
The Journal of Korean Academy of Prosthodontics ; : 515-522, 2021.
Article in English | WPRIM | ID: wpr-918858

ABSTRACT

Successful cases of the implant-assisted removable partial denture and implant overdentures are reported in which a few implants are additionally placed to secure the maintenance, support, and stability of the denture when there are a few residual teeth. When the lateral force applied to the tooth abutment and implant surveyed crown is minimized, the horizontal and rotational movement of the denture is significantly reduced which is an effective method that can improve the address in patients who complain of reduced retention and stability of their dentures. In this case, a small number of implants were placed to fabricate an implant-assisted removable partial denture with implant surveyed crown in the maxilla and implant overdenture with Locator® attachment in the mandible to improve the retention, stability, and support of the dentures. The patient was satisfied with both functional and aesthetic aspects after the final dentures were delivered.

7.
International Journal of Oral Biology ; : 208-213, 2021.
Article in English | WPRIM | ID: wpr-914637

ABSTRACT

Increasing the vertical dimesion affects not only functional problems but also the facial appearance. In particular, when restoring the reduced vertical dimension, it is important to evaluate facial appearance because the change affects the patient’s aesthetics. Cephalometric radiographs can predict changes in the facial appearance through skeletal and vertical classifications using anatomical indicators, and the changes before and after treatment can be easily observed, which could serve as good data in evaluating treatment success. In this study, comparative evaluation was performed through cephalometric radiography, and the aesthetic and functional improvement was confirmed.

SELECTION OF CITATIONS
SEARCH DETAIL