Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 642-650, 2023.
Article in Chinese | WPRIM | ID: wpr-979218

ABSTRACT

ObjectiveTo investigate the effect of myosin heavy chain 7 gene-derived miRNA-208b-3p on the fibrotic phenotype of cardiac fibroblasts. MethodsmiRNA chip array was performed to detect the dysregulated miRNAs in the myocardium of diabetic db/db mice and db/m control mice. Neonatal mouse ventricular cardiomyocytes (NMVCs) and cardiac fibroblasts (CFs) were isolated from C57BL/6 mice and cultured. Real-time quantitative PCR (RT-qPCR) was conducted to determine the expression of miR-208b-3p in mouse CFs and NMVCs subjected to angiotensinⅡ(AngⅡ) and high glucose plus glucose oxidase (G/Go) treatment, respectively. Cell counting kit 8(CCk8) assay, flow cytometry and determination of fibrosis-related protein, including COL1A1, COL3A1and α-SMA, were performed in mCFs transfected with miR-208b-3p. Dual luciferase reporter assay was performed to confirm the interaction between miR-208b-3p and the 3'-UTR of metal response element binding transcription factor 2 (Mtf2) and progesterone receptor membrane component 1(Pgrmc1), respectively. The expressions of Mtf2 and Pgrmc1 at the mRNA and protein levels in mCFs after miR-208b-3p mimic transfection were determined using RT-qPCR and Western blot assay, respectively. The small interfering RNA (siRNA) was used to inhibit Mtf2 and Pgrmc1 expression in mCFs, and the effects of Mtf2 siRNA, Pgrmc1 siRNA and miR-208b-3p on fibrosis-related protein expression in mCFs were investigated. ResultsResults of miRNA chip array and RT-qPCR assay showed that miR-208b-3p was up-regulated in the myocardium of the diabetic db/db mice. miR-208b precursor and the host gene of Myh7 were consistently increased in db/db mice. miR-208b-3p and Myh7 mRNA were expressed in mCFs and NMVCs, but the levels of miR-208b-3p and Myh7 mRNA in NMVCs were much higher than those in mCFs. miR-208b-3p was up-regulated in mCFs and NMVCs subjected to Ang Ⅱ and G/Go treatment, respectively. miR-208b-3p could significantly enhance fibrosis-related protein, including COL1A1, COL3A1 and α-SMA, in mCFs, without affecting the proliferation activity and cell cycle distribution of mCFs. Dual luciferase reporter assay revealed the interactions of miR-208b-3p with the 3'-UTR of Mtf2 and Pgrmc1. The results of RT-qPCR and Western blotting confirmed that miR-208b-3p inhibited Mtf2 and Pgrmc1 expression at the post- transcriptional level. Transfection with miR-208b-3p mimic, Mtf2 siRNA and Pgrmc1 siRNA could consistently enhance the fibrosis-related protein expression in the cardiac fibroblasts. ConclusionsmiR-208b-3p enhances fibrosis-related gene expression by targeting Mtf2 and Pgrmc1in mCFs.

2.
Chinese Journal of Cardiology ; (12): 35-38, 2010.
Article in Chinese | WPRIM | ID: wpr-323880

ABSTRACT

<p><b>OBJECTIVE</b>The aim of this trial is to compare the efficacy and safety between national-made and imported ablation catheters for the treatment of atrioventricular nodal reentrant tachycardia (AVNRT) and atrioventricular reentrant tachycardia (AVRT).</p><p><b>METHOD</b>A total of 1342 patients with AVNRT or AVRT were randomly treated with national-made ablation catheter (Group 1, n = 672) or imported ablation catheter (Group 2, n = 670).</p><p><b>RESULTS</b>The immediate ablation success rate was similar in Group 1 and Group 2 (97.9% vs. 99.1%, P > 0.05). There were also no significant differences in the procedure time [(68 +/- 36) min vs. (67 +/- 34) min], the fluoroscopic time [(14 +/- 14) min vs. (10 +/- 11) min], the number of energy delivery [(4.5 +/- 4.5) beats vs. (4.6 +/- 3.9) beats], the ablation time [(260 +/- 218) s vs. (257 +/- 207) s] and the score of ablation catheter performance evaluation [(4.4 +/- 0.5) vs. (4.5 +/- 0.4) ] between the two groups (all P > 0.05). Three patients developed pericardial effusion (1 in Group 1 and 2 in Group 2, P > 0.05). Incidence of recurrence of tachycardia during the 3 months follow up was similar between the 2 groups (14 in Group1 vs. 16 in Group 2, P > 0.05).</p><p><b>CONCLUSION</b>National-made and imported radiofrequency ablation catheters have similar efficacy and safety for treatment of AVNRT and AVRT.</p>


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Catheter Ablation , Tachycardia, Atrioventricular Nodal Reentry , General Surgery , Tachycardia, Reciprocating , General Surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL