1.
Chinese Journal of Surgery ; (12): 1182-1184, 2009.
Article in Chinese | WPRIM | ID: wpr-299703

ABSTRACT

<p><b>OBJECTIVES</b>To study the best entry points, direction and length of screw in acetabular posterior column plate technique, and to prevent the serious complications of screw penetrating the joint surface.</p><p><b>METHODS</b>February to July 2008 20 male cadaveric adult semi-pelvic specimen were taken.Serial cross-sections of the acetabular posterior column were determined and made. The safe angle of screw entry and the length on all entry points of each cross-section were measured. And put all data into software SPSS 10.0 for statistics process.</p><p><b>RESULTS</b>On margin of acetabulum, lateral-middle 1/4 point, midpoint, medial-middle 1/4 point and medial margin of posterior column of each cross-section, safe entry angle of inclination was 39 degrees , 57 degrees , 74 degrees , 90 degrees and 106 degrees respectively, the length of the screw was 39, 57, 74, 90 and 106 mm respectively.</p><p><b>CONCLUSION</b>On lateral 1/4 region, lateral-middle 1/4 region, medial-middle 1/4 region and medial 1/4 region, screw posterior column angle is 40 degrees to 60 degrees , 60 degrees to 75 degrees , 75 degrees to 90 degrees , 90 degrees to parallel to the quadrilateral plate, and the length of the screw is 30 mm.</p>


Subject(s)
Adult , Humans , Male , Acetabulum , General Surgery , Bone Plates , Bone Screws , Cadaver , Fracture Fixation, Internal , Methods
2.
Chinese Journal of Surgery ; (12): 1700-1703, 2006.
Article in Chinese | WPRIM | ID: wpr-334426

ABSTRACT

<p><b>OBJECTIVE</b>To study the best entry points, direction and length of screw in acetabular anterior column plate technique, and to prevent the serious complications of screw penetrating the joint surface.</p><p><b>METHODS</b>Twenty male cadaveric adult semi-pelvic specimen were taken, and the distance from anterior acetabular margin, posterior acetabular margin to anterior inferior iliac spine, iliopubic eminence and pubic tubercle were measured respectively. Determine and make serial cross-sections of the acetabular anterior column, measure the safe angle of screw entry on all entry points of each cross-section, and put all data into software SPSS 10.0 for statistics process.</p><p><b>RESULTS</b>The distance from anterior acetabular margin to anterior inferior iliac spine, iliopubic eminence and pubic tubercle was (25.4 +/- 1.4) mm, (11.8 +/- 0.7) mm and (37.4 +/- 1.5) mm respectively, the distance from posterior acetabular margin to anterior inferior iliac spine, iliopubic eminence was (15.5 +/- 0.9) mm and (29.1 +/- 1.6) mm respectively. On each cross-section, the maximum of the safe entry angle of inclination in 0.5 cm, 1.0 cm and 1.5 cm entry point lateral to the linea terminalis of pelvis was (8.2 +/- 2.2) degrees , (14.9 +/- 3.4) degrees and (26.1 +/- 4.5) degrees respectively.</p><p><b>CONCLUSIONS</b>When plate for internal fixation on acetabular region of anterior column is used, there are three ways to avoid screw penetrating the joint surface. The first way is using short screw in any direction; the second way is using long screw close to the linea terminalis of pelvis, the direction of the screw is parallel to the quadrilateral plate; the third way is using different entry angle and length according to different entry point.</p>


Subject(s)
Adult , Humans , Male , Acetabulum , General Surgery , Bone Plates , Bone Screws , Cadaver , Fracture Fixation, Internal , Methods , Models, Anatomic