Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Emergency Medicine ; (12): 584-590, 2019.
Article in Chinese | WPRIM | ID: wpr-743272

ABSTRACT

Objective To explore the monitoring of cerebrospinal fluid (CSF) dynamics in a model of brain herniation induced by acute intracranial hypertension in Guangxi Bama-Mini pigs by phasecontrast cine magnetic resonance imaging (PC cine MRI).Methods Femoral artery blood were extracted from 10 pigs,and injected into the frontal and temporal parietal lobe to make a model of brain herniation induced by acute intracranial hypertension.The mean arterial blood pressure (MAP),intracranial pressure (ICP),and cerebral perfusion pressure (CPP) were monitored.Routine T1WI,T2WI,coronal,sagittal and cerebrospinal fluid flow sequence (fast PC cine slice) which positioned on the cervical 3 (C3) vertebral body as the center and perpendicular to the spinal scans were performed on all experimental animals before and after blood injection with 3.0T Magnetic Resonance Imaging.The ICP,MAP,CPP,the absolute values of CSF peak flow velocity and the absolute value of carotid peak flow velocity before and after blood injection were compared.Results The ICP,MAP,CPP,and the absolute value of CSF peak flow velocity before injection of autologous arterial blood were statistically significant as compared with those after blood injection [(6.80±2.044) mmHg vs (52.20±1.619) mmHg,(76.80±7.068) mmHg vs (142.80±12.399) mmHg,(70.00±6.074) mmHg vs (90.50±12.250) mmHg,and the absolute value of CSF peak flow velocity was (243.20±77.671) mm/s vs (201.40±55.482) mm/s,respectively,P<0.01].The absolute value of the peak velocity of the carotid artery before blood injection was not statistically significant compared with that after blood injection [(876.80±239.908) mm/s vs (799.40±241.829) mm/s,P>0.05].Conclusion After the formation of brain herniation induced by acute intracranial hypertension,the CSF flow in the C3 level spinal canal showed a low dynamic change,and the CSF flow velocity waveform was disordered and malformed.The non-invasive measurement of CSF dynamics by PC cine MRI can provide an important basis for the change of CSF dynamics in the model of brain herniation induced by acute intracranial hypertension,and provide a theoretical basis for further research on damage control neurosurgery in the future.

2.
The Journal of Clinical Anesthesiology ; (12): 1180-1182, 2015.
Article in Chinese | WPRIM | ID: wpr-485096

ABSTRACT

Objective To observe the effects of PCIA with oxycodone after laparoscopic surger-y.Methods Forty ASA Ⅰ or Ⅱ patients aged 20-60 years undergoing laparoscopic surgery were as-signed to two groups randomly (n=20 per group):oxycodone group (group A)and fentanyl group (group B).Patients in group A received oxycodone (0.03 mg/kg)and patients in group B received fentanyl (2 μg/kg)at the end of surgery.The PCIA pump was turned on when the patients entered the PACU.The PCIA pump was set up with a 4 ml bolus dose,a 1 5 min lockout interval and a back-ground infusion at the rate of 2 ml/h.Numerical rating scale (NRS)was assessed for the patients in moving,in rest and visceral pain at 3,6,12,24 and 48 h after administration,and the adverse reactions were recorded.Results NRS scores of the rest and visceral pain were significantly lower in group A than in group B at each time point(P <0.05).NRS score of the movement were significantly lower in group A than in group B at 3,6 and 12 h after surgery (P <0.05).There was no significant difference in the incidences of nausea,vomiting,dizziness and respiratory depression between the two groups. Conclusion PCIA with oxycodone can safely and effectively inhibit pain after laparoscopic surgery. The effect of oxycodone for controlling the visceral pain was better than that of fentanyl.

SELECTION OF CITATIONS
SEARCH DETAIL