Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of General Surgery ; (12): 994-997, 2018.
Article in Chinese | WPRIM | ID: wpr-734784

ABSTRACT

Objective To evaluate the safety and efficacy of induced hypotension and hypotension in carotid endarterectomy (CEA).Methods Data of 1 486 patients who underwent CEA in multicenters from Aug 2012 to Aug 2018 were retrospectively analyzed.After screening,a total of 1 448 patients met the inclusion criteria.Induced hypertension and hypotension was used in all thees patients.Results 87.8% of the patients were with severe carotid stenosis.The average operative time was (51.8 ± 6.1) min,and the internal carotid artery clamping time was (11.4 ± 3.1) min.After induced hypertension,the stump pressure were higher than that before,of which 1 438 (99.3%) were greater than 50 mmHg.Monitoring of EEG oxygen saturation showed that the value of ipsilateral rSO2 was significantly lower than that of the contralateral [(56% ± 3%) vs.(64% ± 4%),P < 0.05] before induced hypertension.After induced hypertension and clamp removal,the value of ipsilateral rSO2 was lower than that of the contralateral,but there was not significant difference (all P > 0.05).Perioperative cerebral infarction occurred in 2 cases,ipsilateral cerebral hemorrhage in 1 case,contralateral cerebral hemorrhage in 1 case and myocardial infarction in 2 cases.Connclusion The technique of induced hypotension and hypotension play a temporary role in brain protection for patients undergoing CEA.This study demonstrated the safety and effectiveness of induced hypertension and hypotension technique.

2.
Journal of Interventional Radiology ; (12): 632-636, 2015.
Article in Chinese | WPRIM | ID: wpr-465011

ABSTRACT

Objective To discuss the feasibility, safety and validity of the use of ViabahnTM self-expanding covered stent in endovascular repair of peripheral traumatic pseudoaneurysm (TPA). Methods During the period from June 2012 to April 2014, a total of 8 patients with peripheral TPA were admitted to the Department of Vascular and Endovascular Surgery of Shanghai Changzheng Hospital . The clinical data were retrospective analyzed. The lesions were located at the common carotid artery (n=4), vertebral artery (n=1), subclavian artery (n=1) and superficial femoral artery (n=2). On the basis of acute and chronic TPA classification and different therapeutic principles, endovascular repair with ViabahnTM self-expanding covered stent was employed in 8 patients. Intraoperative angiographic findings, the size and number of the implanted stent, and the immediate angiographic results after stent implantation were recorded. All the patients were followed up to evaluate the improvement of the symptoms, the effectiveness of the repair of TPA cavity, and the occurrence of endoleak or restenosis. Results Successful implantation of ViabahnTM self-expanding covered stent was accomplished in all 8 patients, with a technical success rate of 100%. Angiography performed immediately after stent implantation showed that complete repair of TPA cavity was obtained in all patients, the distal segment of the parent artery was patent, and no endoleak was observed. The sizes of the stent used in the patients were 8×50 mm (n=2) and 9×50 mm (n=2) in common carotid artery, 6×50 mm (n=1) in vertebral artery, 11×100 mm (n=1) in subclavian artery, and 8×100 mm (n=2) in superficial femoral artery. The patients were followed up for 6-30 months (mean of 14.3 months), and the clinical symptoms disappeared in all patients. CT angiography indicated that there was no endoleak or restenosis. Conclusion Based on the different therapeutic principles, the use of ViabahnTM self-expanding covered stent in endovascular repair of peripheral TPA is technically simple and micro-invasive, and clinically feasible with reliable effect and safety. Therefore, this technique can be employed as a first-line therapy option for peripheral TPA.

SELECTION OF CITATIONS
SEARCH DETAIL