Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 342-7, 2011.
Article in English | WPRIM | ID: wpr-635112

ABSTRACT

This study examined the role of regulated upon activation normal T cell expressed and secreted (RANTES) and its receptor C-C chemokine receptor type 5 (CCR5) in gastric cancer metastasis and the associated mechanism. The expression of RANTES and CCR5 was detected by using immunohistochemical staining and Western blotting in the gastric cancer tissues obtained from 60 gastric cancer patients with or without lymph node metastasis (n=30 in each). The results showed that the expression levels of RANTES and CCR5 were higher in gastric cancer with lymph node metastasis than in that without metastasis (P<0.05). The expression levels of RANTES in 30 lymph nodes with cancerous invasion were higher than in 30 normal lymph nodes (P<0.05). Chemotactic test revealed that the number of migrating gastric cancer cells (n=295.0±54.6) induced by the protein of cancer-invading lymph nodes was greater than that by the protein mixture from cancer-invading lymph nodes and RANTES antibody (n=42.5±11.6) (P<0.05). RT-PCR showed that the expression levels of the main Th1 cytokines (IL-2, Γ-IFN) were lower in gastric cancer with lymph node metastasis (2.22±0.90, 3.26±1.15 respectively) than in that without metastasis (3.07±1.67, 4.77±1.52 respectively) (P<0.05), but the expression level of the main Th 2 cytokine (IL-10) was higher in gastric cancer with lymph nodes metastasis (6.06±2.04) than in that without metastasis (4.88±1.87) (P<0.05). It was concluded that RANTES and its receptor CCR5 may contribute to gastric cancer metastasis through influencing the balance of Th1/Th2. RANTES and CCR5 may become a marker of gastric cancer metastasis.

2.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-683663

ABSTRACT

This paper introduces a multi-function adjustable anesthetic laryngoscope.The laryngocope or called tongue-spatula can be adjusted freely in length between12-14cm and in ante-posterior diameter between 2.8-4.5cm according to patients'condition.An oxygen -supply pipe and suction tube are settled on the bottom and side of tongue-spatula to provide oxygen and absorb phlegm simultaneously on exposure of glottis.The tongue-spatula not only fits for normal adults but also for those with high prominewtia,short neck,long epiglottis, absent of incisor teeth as well as tall and fatty persons.It has got satisfying result in 29 cases of medical experiment.

SELECTION OF CITATIONS
SEARCH DETAIL