Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Trauma ; (12): 714-720, 2022.
Article in Chinese | WPRIM | ID: wpr-956497

ABSTRACT

Objective:To investigate the clinical efficacy of wrist arthroscopic transosseous footprint repair technique for treating triangular fibrocartilage complex (TFCC) injury.Methods:A retrospective case series study was conducted to analyze the clinical data of 56 patients with TFCC injury admitted to Shenzhen Second People′s Hospital from July 2017 to September 2020, including 38 males and 18 females, aged 17-45 years [(33.5±3.6)years]. All patients had unilateral injury. Physical examination showed instability of the distal radioulnar joint, and MRI and arthroscopy confirmed deep ligament injury of TFCC. All patients underwent repair of deep insertion of the TFCC by using wrist arthroscopic transosseous footprint. The operation time, intraoperative blood loss, wound healing and postoperative complications were recorded. The flexion and extension range of motion of the wrist, radial and ulnal deviation of the wrist, rotation range of motion of the forearm, patient related wrist evaluation (PRWE) score, modified Mayo wrist score, visual analogue scale (VAS), and percentage of grip strength between the affected side and unaffected side were compared preoperatively, at 3 months postoperatively and at 1 year postoperatively.Results:All patients were followed up for 12-18 months [(13.4±5.2)months]. The operation time was (61.3±8.9)minutes, with the intraoperative blood loss of (2.4±1.2)ml. All wounds were healed by first intension. There was no wound infection or ulnar nerve irritation symptom after operation. Four patients experienced clicking on the ulnar side of the wrist in a short period of time post-operation, with spontaneous disappearance of the symptom. At 3 months postoperatively, the radial and ulnar deviation of the wrist was decreased from (52.5±5.9)° preoperatively to (42.6±5.9)°, and rotation range of motion of the forearm was decreased from (94.9±8.4)°preoperatively to (84.6±5.9)° (all P<0.01). The flexion and extension range of motion of the wrist was (93.1±17.4)° preoperatively, with insignificant difference compared with (89.4±5.8)° at 3 months postoperatively ( P>0.05). At 1 year postoperatively, the flexion and extension range of motion of the wrist, radial and ulnar deviation range of motion of the wrist, and rotation range of motion of the forearm were significantly increased to (101.3±13.6)°, (52.4±6.6)°, and (116.4±16.4)° when compared with those at 3 months postoperatively (all P<0.01). At 3 months postoperatively, the PRWE score was increased to (17.1±3.8)points from (10.6±3.2)points preoperatively ( P<0.01), modified Mayo wrist score was decreased to (70.3±6.7) points from (78.1±12.7)points preoperatively ( P<0.01), VAS was decreased to (4.4±1.7)points from (6.2±1.5)points preoperatively ( P>0.05), and percentage of grip strength between the affected side and unaffected side was decreased to (55.7±8.7)% from (74.4±15.2)% preoperatively ( P<0.01). At 1 year postoperatively, the PRWE score was increased to (2.0±0.9)points, modified Mayo wrist score was increased to (94.8±3.3)points, VAS was decreased to (2.1±1.1)points, and percentage of grip strength between the affected side and unaffected side was increased to (93.2±8.7)% when compared with those at 3 months postoperatively (all P<0.01). Conclusion:Wrist arthroscopic transosseous footprint repair technique can effectively treat deep ligament injury of TFCC, with advantages of significantly improving postoperative joint range of motion and functional score, relieving the pain on the ulnar side of the wrist and enhancing grip strength.

2.
Chinese Journal of Orthopaedics ; (12): 699-706, 2019.
Article in Chinese | WPRIM | ID: wpr-755210

ABSTRACT

Objective To analyze the clinical effects of arthroscopic autologous bone grafting and percutaneous fixation in treating scaphoid nonunion.Methods From May 2013 to August 2017,a total of 25 cases of patients including 20 males and 5 females with unilateral scaphoid fractures and nonunion were reviewed,with mean age of 35.80±2.41 years (18-65 years).The duration from injury to treatment was averaged 11.70± 1.90 months (5-18 months).All of the cases sustained waist and proximal end fractures.X-ray and CT scan showed sclerosis and bone resorption without any callus at the fracture sites.However,there were no serious deformities and wrist arthritis.The patients suffered pain and weakness at the radial side of the wrist.The type of the fractures were Slade-Geissler's Ⅲ-Ⅵ,including grade Ⅲ 4 cases,grade Ⅳ 13 cases,grade Ⅴ 7 cases and grade Ⅵ 1 case.The patients were treated with arthroscopic debridement of the sclerotic bone,autologous bone grafting,percutaneous screw (9 cases) or K-wires fixation (16 cases) and immobilization by plaster for 3 weeks after operation,followed by functional rehabilitation training.Bone union was assessed by serial plain radiographs and CT scan regularly.The functional effects were evaluated by comparing the modified Mayo wrist score with the visual analogue scale (VAS) for pain,range of motion (ROM) and the grip strength,which were measured before operation and at 18 months after operation.Results All cases were followed up.Bone union was achieved in all of 25 nonunion.The average radiological union duration was 10.24±2.10 weeks (6-20 weeks).The average VAS score decreased from 6.75± 1.10 preoperatively to 1.33±0.21.The mean ROM of wrist was improved to 168.48°± 12.41 ° (92.90% of that of the normal side),compared to that of 135.24°± 17.47° preoperatively (79.80% of that of the normal side).The mean grip strength showed improvement from an average of 35.68±3.81 kg (80.46% of that of normal side) preoperatively to 48.75±4.42 kg (90.65% of that of normal side).The average modified Mayo wrist score improved from 61.52±6.32 preoperatively to 85.88±8.37.Conclusion Arthroscopic autologous bone grafting with percutaneous cannulated screw and K-wires fixation is an effective and minimally invasive treatment for seaphoid nonunion,which could protect the blood supply of the fracture sites,decrease the surgical complications,promote bone healing and lead to a faster recovery.

3.
Chinese Journal of Orthopaedics ; (12): 699-706, 2019.
Article in Chinese | WPRIM | ID: wpr-801440

ABSTRACT

Objective@#To analyze the clinical effects of arthroscopic autologous bone grafting and percutaneous fixation in treating scaphoid nonunion.@*Methods@#From May 2013 to August 2017, a total of 25 cases of patients including 20 males and 5 females with unilateral scaphoid fractures and nonunion were reviewed, with mean age of 35.80±2.41 years (18-65 years). The duration from injury to treatment was averaged 11.70±1.90 months (5-18 months). All of the cases sustained waist and proximal end fractures. X-ray and CT scan showed sclerosis and bone resorption without any callus at the fracture sites. However, there were no serious deformities and wrist arthritis. The patients suffered pain and weakness at the radial side of the wrist. The type of the fractures were Slade-Geissler's III-VI, including grade III 4 cases, grade IV 13 cases, grade V 7 cases and grade VI 1 case. The patients were treated with arthroscopic debridement of the sclerotic bone, autologous bone grafting, percutaneous screw (9 cases) or K-wires fixation (16 cases) and immobilization by plaster for 3 weeks after operation, followed by functional rehabilitation training. Bone union was assessed by serial plain radiographs and CT scan regularly. The functional effects were evaluated by comparing the modified Mayo wrist score with the visual analogue scale (VAS) for pain, range of motion (ROM) and the grip strength, which were measured before operation and at 18 months after operation.@*Results@#All cases were followed up. Bone union was achieved in all of 25 nonunion. The average radiological union duration was 10.24±2.10 weeks (6-20 weeks). The average VAS score decreased from 6.75±1.10 preoperatively to 1.33±0.21. The mean ROM of wrist was improved to 168.48°±12.41° (92.90% of that of the normal side), compared to that of 135.24°±17.47° preoperatively (79.80% of that of the normal side). The mean grip strength showed improvement from an average of 35.68±3.81 kg (80.46% of that of normal side) preoperatively to 48.75±4.42 kg (90.65% of that of normal side). The average modified Mayo wrist score improved from 61.52±6.32 preoperatively to 85.88±8.37.@*Conclusion@#Arthroscopic autologous bone grafting with percutaneous cannulated screw and K-wires fixation is an effective and minimally invasive treatment for scaphoid nonunion, which could protect the blood supply of the fracture sites, decrease the surgical complications, promote bone healing and lead to a faster recovery.

4.
Chinese Journal of Tissue Engineering Research ; (53): 296-302, 2017.
Article in Chinese | WPRIM | ID: wpr-508492

ABSTRACT

BACKGROUND:Silicon plays an essential role in bone development and bioactive silicate glasses pioneered the current era of bioactive materials. Various biomaterials have been developed based on the biological function of silicon. OBJECTIVE:To explore the biological function of silicon and research process of silicon in biomaterials. METHODS: A computer-based retrieval of CNKI, PubMed, SpringerLink and Elsevier ScienceDirect databases was performed to search the relevant literatures concerning the biological function of silicon and its application in biomaterials. Al data were primarily screened to exclude repeated and irrelevant articles. Literatures about the application of silicon in biomaterials were included. RESULTS AND CONCLUSION:A total of 68 eligible English articles are enroled. Silicon plays important chemical and biological roles in bone. Silicon in the extracelular matrix interacts with glycosaminoglycans and proteoglycans during their synthesis and form ionic substitutions in the crystal lattice structure of hydroxyapatite. In addition, the dissolution products of bioactive glass (mainly silicic acid) expose significant influence on the molecular biology of osteoblasts in vitro, and can regulate the expressions of several genes including osteoblastic markers, cel cycle regulators and extracelular matrix proteins. Silicon has been proved to improve the bioactivity of numerous materials and do no harm to their mechanical properties and without cytotoxicity.

SELECTION OF CITATIONS
SEARCH DETAIL